Kinetics and the on-site application of standards in a solid-phase microextration fiber

被引:114
作者
Chen, Y [1 ]
Pawliszyn, J [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
关键词
D O I
10.1021/ac0495081
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The kinetics of the desorption of analytes from a SPME fiber into an agitated sample matrix was studied, and a theoretical model was proposed to describe the dynamic desorption process, based on the steady-state diffusion of analytes in the extraction phase and in the boundary layer. It was found that the desorption of analytes from a SPME fiber into an agitated sampling matrix is isotropic to the absorption of the analytes onto the SPME fiber from the sample matrix under the same agitation conditions, and this allows for the calibration of absorption using desorption. The calibration was accomplished by exposing a SPME fiber, preloaded with a standard, to an agitated sample matrix, during which desorption of the standard and absorption of analytes occurred simultaneously. When the standard was the isotopically labeled analogue of the target analyte, the information from the desorption process, i.e., time constant a, could be directly used for estimating the concentration of the target analyte. When the standard varied from the target analyte, the mass-transfer coefficient of the analyte could be extrapolated from that of the standard. These predictions agree well with experimental results. This approach facilitates the full integration of sampling, sample preparation, and sample introduction, especially for on-site or in vivo investigations, where the addition of standards to the sample matrix, or control of the velocity of the sample matrix, is very difficult.
引用
收藏
页码:5807 / 5815
页数:9
相关论文
共 15 条
[1]   Solid phase microextraction for quantitative analysis in nonequilibrium situations [J].
Ai, J .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1230-1236
[2]  
[Anonymous], APPL SOLID PHASE MIC, DOI DOI 10.1039/9781847550149-00169
[3]   ANALYSIS OF ENVIRONMENTAL AIR SAMPLES BY SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHY ION-TRAP MASS-SPECTROMETRY [J].
CHAI, M ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (03) :693-701
[4]   Calibration for on-site analysis of hydrocarbons in aqueous and gaseous samples using solid-phase microextraction [J].
Chen, Y ;
Koziel, JA ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2003, 75 (23) :6485-6493
[5]  
Cussler E. L., 2009, DIFFUSION MASS TRANS
[6]  
GRECKI T, 1999, APPL SOLID PHASE MIC, P92
[7]   Air sampling with porous solid-phase microextraction fibers [J].
Koziel, J ;
Jia, MY ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :5178-5186
[8]   Field air analysis with SPME device [J].
Koziel, J ;
Jia, MY ;
Khaled, A ;
Noah, J ;
Pawliszyn, J .
ANALYTICA CHIMICA ACTA, 1999, 400 :153-162
[9]   System for the generation of standard gas mixtures of volatile and semi-volatile organic compounds for calibrations of solid-phase microextraction and other sampling devices [J].
Koziel, JA ;
Martos, PA ;
Pawliszyn, J .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1025 (01) :3-9
[10]   Estimation of air/coating distribution coefficients for solid phase microextraction using retention indexes from linear temperature-programmed capillary gas chromatography. Application to the sampling and analysis of total petroleum hydrocarbons in air [J].
Martos, PA ;
Saraullo, A ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :402-408