Determination of sulfite by flow injection analysis using a poly [Ni-(protoporphyrin IX)] chemically modified electrode

被引:54
作者
Carballo, R [1 ]
Dall'Orto, VC [1 ]
Lo Balbo, A [1 ]
Rezzano, I [1 ]
机构
[1] Univ Buenos Aires, Fac Farm & Bioquim, RA-1113 Buenos Aires, DF, Argentina
关键词
poly[Ni-(protoporphyrin IX)] film; sulfite; flow injection; amperometric detection;
D O I
10.1016/S0925-4005(02)00319-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method for quantification of both free and total SO2 is described. Poly[Ni-(protoporphyrin IX)] (NiPPIX) film at submonolayer-level-modified glassy carbon electrodes showed an important catalytic effect for the oxidation of SO2. This modified electrode is an useful tool in chemical analysis when it is incorporated to an amperometric detector in a flow or in a stirred system. The method gives a linear range up to 9.0 mug ml(-1) and a detection limit of 0.15 mug ml(-1) for SO2. The described method is simple and non-expensive. Surface coating is highly stable under hydrodynamic conditions in the flow cell. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:155 / 161
页数:7
相关论文
共 22 条
[1]   Electrochemical detection of NADH and dopamine in flow analysis based on tetraruthenated porphyrin modified electrodes [J].
Angnes, L ;
Azevedo, CMN ;
Araki, K ;
Toma, HE .
ANALYTICA CHIMICA ACTA, 1996, 329 (1-2) :91-95
[2]  
*AOAC, 1984, OFF METH AN
[3]   ELECTROCHEMISTRY OF A TETRARUTHENATED COBALT PORPHYRIN AND ITS USE IN MODIFIED ELECTRODES AS SENSORS OF REDUCING ANALYTES [J].
ARAKI, K ;
ANGNES, L ;
AZEVEDO, CMN ;
TOMA, HE .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 397 (1-2) :205-210
[4]   ELECTROANALYTICAL APPLICATIONS IN OCCUPATIONAL AND ENVIRONMENTAL-HEALTH [J].
ASHLEY, K .
ELECTROANALYSIS, 1994, 6 (10) :805-820
[5]   Determination of sulfur dioxide in wines by gas-diffusion flow injection analysis utilizing modified electrodes with electrostatically assembled films of tetraruthenated porphyrin [J].
Azevedo, CMN ;
Araki, K ;
Toma, HE ;
Angnes, L .
ANALYTICA CHIMICA ACTA, 1999, 387 (02) :175-180
[6]  
BALDINI E, 2002, ELECTROANAL, V14, P1
[7]   Determination of bisphenol A in food-simulating liquids using LCED with a chemically modified electrode [J].
D'Antuono, A ;
Dall'Orto, VC ;
Lo Balbo, A ;
Sobral, S ;
Rezzano, I .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (03) :1098-1101
[8]  
Dall'Orto VC, 1998, ELECTROANAL, V10, P127, DOI 10.1002/(SICI)1521-4109(199802)10:2<127::AID-ELAN127>3.3.CO
[9]  
2-V
[10]   Liquid chromatography/electrochemical detection of phenols at a poly[Ni-(Protoporphyrin IX)] chemically modified electrode [J].
DallOrto, VC ;
Danilowicz, C ;
Sobral, S ;
LoBalbo, A ;
Rezzano, I .
ANALYTICA CHIMICA ACTA, 1996, 336 (1-3) :195-199