T2-weighted fast MR imaging with true FISP versus HASTE: Comparative efficacy in the evaluation of normal fetal brain maturation

被引:78
作者
Chung, HW
Chen, CY
Zimmerman, RA
Lee, KW
Lee, CC
Chin, SC
机构
[1] Tri Serv Gen Hosp, Dept Radiol, Taipei 100, Taiwan
[2] Natl Def Med Ctr, Taipei 100, Taiwan
[3] Natl Taiwan Univ, Dept Elect Engn, Taipei 10764, Taiwan
[4] Childrens Hosp, Dept Radiol, Philadelphia, PA 19104 USA
关键词
D O I
10.2214/ajr.175.5.1751375
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE, This study compares the relative efficacy of two fast T2-weighted MR imaging techniques-fast imaging with steady-state free precession (true FISP) and half-Fourier acquisition single-shot turbo spin-echo (HASTE)-in the evaluation of the normal fetal brain maturation during the second and third trimesters of gestation. SUBJECTS AND METHODS. The brain maturation of 10 normal nonsedated fetuses (5 during the second trimester and 6 during the third trimester of gestation [1 fetus underwent 2 examinations]) was examined by both techniques using a Vision + 1.5-T MR system. We specifically looked for developing events, including white matter myelination, neuronal migration, and cortical sulcation. Image quality was graded according to the presence or absence of undesirable blurring. RESULTS. The specific absorption rate was lower for true FISP than for HASTE by a factor of 3 at equivalent imaging conditions. HASTE and true FISP provide comparable image quality in the second trimester when myelination of the cerebrum has not begun. Neuronal migration could be recognized as hypodense bands on both sequences during the second trimester. Myelination beginning at the third trimester was better delineated with true FISP than with HASTE because of point spread function-related blurring effects inherent in HASTE that hampered visualization of short-T2 structures. Cortical sulcation was well delineated by both sequences. CONCLUSION. With relatively superior image quality and significantly lower radiofrequency absorption than HASTE, true FISP is a safer and more effective alternative in the prenatal evaluation of normal fetal brain.
引用
收藏
页码:1375 / 1380
页数:6
相关论文
共 29 条
[1]  
Brisse H, 1997, AM J NEURORADIOL, V18, P1491
[2]   GYRAL DEVELOPMENT OF HUMAN-BRAIN [J].
CHI, JG ;
DOOLING, EC ;
GILLES, FH .
ANNALS OF NEUROLOGY, 1977, 1 (01) :86-93
[3]   Complex fetal disorders: Effect of MR imaging on management - Preliminary clinical experience [J].
Coakley, FV ;
Hricak, H ;
Filly, RA ;
Barkovich, AJ ;
Harrison, MR .
RADIOLOGY, 1999, 213 (03) :691-696
[4]   THE LOSS OF SMALL OBJECTS IN VARIABLE TE IMAGING - IMPLICATIONS FOR FSE, RARE, AND EPI [J].
CONSTABLE, RT ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) :9-24
[5]   Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at .2 T [J].
Duerk, JL ;
Lewin, JS ;
Wendt, M ;
Petersilge, C .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :203-208
[6]   PHASE AND INTENSITY ANOMALIES IN FOURIER TRANSFORM NMR [J].
FREEMAN, R ;
HILL, HDW .
JOURNAL OF MAGNETIC RESONANCE, 1971, 4 (03) :366-&
[7]  
Friede R., 1989, DEV NEUROPATHOLOGY, V2nd, P2
[8]   STEADY-STATE FREE PRECESSION IMAGING IN THE PRESENCE OF MOTION - APPLICATION FOR IMPROVED VISUALIZATION OF THE CEREBROSPINAL-FLUID [J].
HAACKE, EM ;
WIELOPOLSKI, PA ;
TKACH, JA ;
MODIC, MT .
RADIOLOGY, 1990, 175 (02) :545-552
[9]  
HASEGAWA M, 1992, BRAIN DEV-JPN, V14, P1
[10]   Cortical maturation in normal and abnormal fetuses as assessed with prenatal MR imaging [J].
Levine, D ;
Barnes, PD .
RADIOLOGY, 1999, 210 (03) :751-758