Nanosensor for in vivo measurement of the carcinogen benzo[a]pyrene in a single cell

被引:31
作者
Kasili, RM [1 ]
Cullum, BM [1 ]
Griffin, GD [1 ]
Vo-Dinh, T [1 ]
机构
[1] Oak Ridge Natl Lab, Div Life Sci, Adv Biomed Sci & Technol Grp, Oak Ridge, TN 37831 USA
关键词
nanosensor; single cell; benzo[a]pyrene; antibody immobilization; fluorescence;
D O I
10.1166/jnn.2002.155
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This work describes the fabrication and the application of an antibody-based fiber-optic nanosensor for in situ measurements of the carcinogen benzo[a]pyrene (BaP) in a single cell. This antibody-based spectroscopic nanosensor is miniaturized enabling the detection of fluorescent analytes in single cells. In addition to measuring fluorescent analytes in single cells, the nanosensor has the potential to be applied for both diagnostic and proteomics purposes. In this work, the human breast carcinoma cell line, MCF-7, was used as the model system to perform BaP measurements in single cells. A standard concentration curve for BaP was established and used to perform quantitative analyses of BaP in individual cells. From these analyses, it was estimated that the concentration of BaP in the individual cells investigated was similar to3.61 x 10(-10) M. The results obtained demonstrate the application of antibody-based nanosensors for performing in situ measurements inside a single cell.
引用
收藏
页码:653 / 658
页数:6
相关论文
共 17 条
[1]   Development and cellular applications of fiber optic nitric oxide sensors based on a gold-adsorbed fluorophore [J].
Barker, SLR ;
Kopelman, R .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4902-4906
[2]   Fluorescent nanosensors for intracellular chemical analysis: Decyl methacrylate liquid polymer matrix and ion exchange-based potassium PEBBLE sensors with real-time application to viable rat C6 glioma cells [J].
Brasuel, M ;
Kopelman, R ;
Miller, TJ ;
Tjalkens, R ;
Philbert, MA .
ANALYTICAL CHEMISTRY, 2001, 73 (10) :2221-2228
[3]  
Castellano AV, 1999, AFINIDAD, V56, P113
[4]   Optical nanosensors for chemical analysis inside single living cells. 1. Fabrication, characterization, and methods for intracellular delivery of PEBBLE sensors [J].
Clark, HA ;
Hoyer, M ;
Philbert, MA ;
Kopelman, R .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4831-4836
[5]   Optical nanosensors for chemical analysis inside single living cells. 2. Sensors for pH and calcium and the intracellular application of PEBBLE sensors [J].
Clark, HA ;
Kopelman, R ;
Tjalkens, R ;
Philbert, MA .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4837-4843
[6]   Intracellular measurements in mammary carcinoma cells using fiber-optic nanosensors [J].
Cullum, BM ;
Griffin, GD ;
Miller, GH ;
Vo-Dinh, T .
ANALYTICAL BIOCHEMISTRY, 2000, 277 (01) :25-32
[7]   The development of optical nanosensors for biological measurements [J].
Cullum, BM ;
Vo-Dinh, T .
TRENDS IN BIOTECHNOLOGY, 2000, 18 (09) :388-393
[8]  
GRIFFIN GD, 1985, POLYNUCLEAR AROMATIC
[9]   Time- and dose-dependent DNA binding of PAHs derived from diesel particle extracts, benzo[a]pyrene and 5-methylchrysene in a human mammary carcinoma cell line (MCF-7) [J].
Kuljukka-Rabb, T ;
Peltonen, K ;
Isotalo, S ;
Mikkonen, S ;
Rantanen, L ;
Savela, K .
MUTAGENESIS, 2001, 16 (04) :353-358
[10]  
LIN JN, 1988, IEEE T BIO-MED ENG, V35, P466