The 6.5 meter MMT's f/5 wide-field optics and instruments

被引:22
作者
Fabricant, D [1 ]
Fata, R [1 ]
McLeod, B [1 ]
Szentgyorgyi, A [1 ]
Barberis, J [1 ]
Bergner, H [1 ]
Brown, W [1 ]
Caldwell, N [1 ]
Conroy, M [1 ]
Eng, R [1 ]
Epps, H [1 ]
Furesz, G [1 ]
Gauron, T [1 ]
Geary, J [1 ]
Goddard, R [1 ]
Hartmann, L [1 ]
Hertz, E [1 ]
Honsa, M [1 ]
Mueller, M [1 ]
Norton, T [1 ]
Ordway, M [1 ]
Roll, J [1 ]
Williams, G [1 ]
Freedman-Woods, D [1 ]
Zajac, J [1 ]
机构
[1] Harvard Smithsonian Ctr Astrophys, Cambridge, MA 02138 USA
来源
GROUND-BASED INSTRUMENTATION FOR ASTRONOMY, PTS 1-3 | 2004年 / 5492卷
关键词
optical design; spectrographs; imagers; CCD mosaic; telescopes;
D O I
10.1117/12.551729
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
In 2003, the converted MMT's wide-field f/5 focus was commissioned. A 1.7-m diameter secondary and a large refractive corrector offer a 1degrees diameter field of view for spectroscopy and a 0.5degrees diameter field of view for imaging. Stellar images during excellent seeing are smaller than 0.5" FWHM across the spectroscopic field of view, and smaller than 0.4" across the imaging field of view. Three wide-field f/5 instruments are now in routine operation: Hectospec (an Rsimilar to1000 optical spectrograph fed by 300 robotically-positioned optical fibers), Hectochelle (an Rsimilar to40,000 optical spectrograph fed by the same fibers), and Megacam (a 340 megapixel, 36 CCD optical imager covering a 25' by 25' format).
引用
收藏
页码:767 / 778
页数:12
相关论文
共 13 条
[1]   Coping with data deluge - a data system for the Megacam [J].
Conroy, TA ;
Roll, JB ;
Wyatt, WF ;
Mink, DJ ;
McLeod, BA .
OPTICAL ASTRONOMICAL INSTRUMENTATION, PTS 1 AND 2, 1998, 3355 :264-274
[2]  
FABRICANT D, 1994, P SOC PHOTO-OPT INS, V2198, P251, DOI 10.1117/12.176702
[3]   Construction of the Hectospec: 300 optical fiber-fed spectrograph for the converted MMT [J].
Fabricant, DG ;
Hertz, EN ;
Szentgyorgyi, AH ;
Fata, RG ;
Roll, JB ;
Zajac, JM .
OPTICAL ASTRONOMICAL INSTRUMENTATION, PTS 1 AND 2, 1998, 3355 :285-296
[4]  
FATA R, 1994, P SOC PHOTO-OPT INS, V2199, P580, DOI 10.1117/12.176226
[5]  
FATA R, 1993, P SOC PHOTO-OPT INS, V1998, P32, DOI 10.1117/12.156628
[6]   Mounting large lenses in wide-field instruments for the converted MMT [J].
Fata, RG ;
Fabricant, DG .
OPTICAL ASTRONOMICAL INSTRUMENTATION, PTS 1 AND 2, 1998, 3355 :275-284
[7]   Camera electronics for the 72-channel SAO Megacam [J].
Geary, JC ;
Amato, SM .
OPTICAL ASTRONOMICAL INSTRUMENTATION, PTS 1 AND 2, 1998, 3355 :539-546
[8]   Optical fiber for UV-IR broadband spectroscopy [J].
Lu, G ;
Schotz, GF ;
Vydra, J ;
Fabricant, D .
OPTICAL ASTRONOMICAL INSTRUMENTATION, PTS 1 AND 2, 1998, 3355 :884-891
[9]  
MCLEOD B, 1996, P SOC PHOTO-OPT INS, V2654, P223
[10]   Megacam: paving the focal plane of the MMT with silicon [J].
McLeod, BA ;
Gauron, TM ;
Geary, JC ;
Ordway, MP ;
Roll, JB .
OPTICAL ASTRONOMICAL INSTRUMENTATION, PTS 1 AND 2, 1998, 3355 :477-486