Resolution measurement in structures derived from single particles

被引:102
作者
Grigorieff, N [1 ]
机构
[1] Brandeis Univ, Howard Hughes Med Inst,Dept Biochem, Rosenstiel Basic Med Sci Res Ctr, WM Keck Inst Cellular Visualizat, Waltham, MA 02454 USA
来源
ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY | 2000年 / 56卷
关键词
D O I
10.1107/S0907444900009549
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Analytical expressions are derived and computer simulations are presented to assess the accuracy of procedures commonly used to estimate the resolution of three-dimensional (3D) structures derived from images of single protein molecules or complexes. It is shown that in the case of a low signal-to-noise ratio in the images, the Fourier ring correlation between two structures, each calculated using one half of the data, significantly overestimates the resolution when the two half data sets were aligned against the same reference structure. The overestimate arises because of a correlation between the noise components present in the images. The correlation is introduced by the alignment and becomes more serious as the signal-to-noise ratio is reduced. A reliable resolution measure is only obtained when the two half data sets are aligned against two independent reference structures. It is further shown that the noise correlation also significantly affects the spectral signal-to-noise ratio and the Q factor, making them unreliable measures of signal present in a 3D structure and in the original images, respectively. It is concluded that the alignment of images is always accompanied by a correlation of the noise and that this correlation is indistinguishable from a correlation arising from a signal.
引用
收藏
页码:1270 / 1277
页数:8
相关论文
共 23 条
[1]  
[Anonymous], 1996, 3 DIMENSIONAL ELECT
[2]  
[Anonymous], 1974, INTRO THEORY STAT
[3]   Determination of the fold of the core protein of hepatitis B virus ky electron cryomicroscopy [J].
Bottcher, B ;
Wynne, SA ;
Crowther, RA .
NATURE, 1997, 386 (6620) :88-91
[4]   Visualization of a 4-helix bundle in the hepatitis B virus capsid by cryo-electron microscopy [J].
Conway, JF ;
Cheng, N ;
Zlotnick, A ;
Wingfield, PT ;
Stahl, SJ ;
Steven, AC .
NATURE, 1997, 386 (6620) :91-94
[5]   SIGNAL-TO-NOISE RATIO OF ELECTRON MICROGRAPHS OBTAINED BY CROSS-CORRELATION [J].
FRANK, J ;
ALALI, L .
NATURE, 1975, 256 (5516) :376-379
[6]   SPIDER and WEB: Processing and visualization of images in 3D electron microscopy and related fields [J].
Frank, J ;
Radermacher, M ;
Penczek, P ;
Zhu, J ;
Li, YH ;
Ladjadj, M ;
Leith, A .
JOURNAL OF STRUCTURAL BIOLOGY, 1996, 116 (01) :190-199
[7]   Solution structure of the E. coli 70S ribosome at 11.5 Å resolution [J].
Gabashvili, IS ;
Agrawal, RK ;
Spahn, CMT ;
Grassucci, RA ;
Svergun, DI ;
Frank, J ;
Penczek, P .
CELL, 2000, 100 (05) :537-549
[8]  
GRIGORIEFF N, 1999, 647 TU BERL REIH FAC
[9]  
HARAUZ G, 1986, OPTIK, V73, P146
[10]   IMAGE-CONTRAST IN HIGH-RESOLUTION ELECTRON-MICROSCOPY OF BIOLOGICAL MACROMOLECULES - TMV IN ICE [J].
HENDERSON, R .
ULTRAMICROSCOPY, 1992, 46 (1-4) :1-18