Computation of glass-cover temperatures and top heat loss coefficient of flat-plate solar collectors with double glazing

被引:60
作者
Akhtar, N. [1 ]
Mullick, S. C.
机构
[1] Govind Ballabh Pant Univ Agr & Technol, Coll Technol, Dept Mech Engn, Pantnagar 263145, Uttar Pradesh, India
[2] Indian Inst Technol, Ctr Energy Studies, New Delhi 110016, India
关键词
glass-cover temperatures; top heat loss coefficient; flat-plate solar collectors with double glazing; PERFORMANCE;
D O I
10.1016/j.energy.2006.07.007
中图分类号
O414.1 [热力学];
学科分类号
摘要
A set of correlations for computing the glass-cover temperatures of flat-plate solar collectors with double glazing is developed. A semianalytical correlation for the factor f(2) - the ratio of outer to inner thermal resistance of a double-glazed collector - as a function of collector parameters and atmospheric variables is obtained by regression analysis. This relation readily provides the temperature of the second (outer) glass cover (T-2). For estimating the temperature of first (inner) glass cover (T-1), another relation for the factor f(1) - the ratio of thermal resistance between the two glass covers to the thermal resistance between the absorber plate and first glass cover - is developed. A wide range of variables is covered in the present analysis. The results are compared with those obtained by numerical solutions of heat-balance equations. Using the proposed relations of glass-cover temperatures, the values of top heat loss coefficient (U-t) can be computed and are found to be very close to those obtained by numerical solutions of heat-balance equations. The maximum absolute error in the calculation of U-t by the proposed method is only 1.0%, so numerical solutions of heat-balance equations for the computation of U-t are not required. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1067 / 1074
页数:8
相关论文
共 17 条
[1]   CALCULATION OF THE TOP LOSS COEFFICIENT OF A FLAT-PLATE COLLECTOR [J].
AGARWAL, VK ;
LARSON, DC .
SOLAR ENERGY, 1981, 27 (01) :69-71
[2]   Approximate method for computation of glass cover temperature and top heat-loss coefficient of solar collectors with single glazing [J].
Akhtar, N ;
Mullick, SC .
SOLAR ENERGY, 1999, 66 (05) :349-354
[3]  
[Anonymous], T ASME
[4]   PERFORMANCE ANALYSIS OF SOLAR AIR HEATERS OF CONVENTIONAL DESIGN [J].
BIONDI, P ;
CICALA, L ;
FARINA, G .
SOLAR ENERGY, 1988, 41 (01) :101-107
[5]   NATURAL-CONVECTION IN ENCLOSED SPACES - REVIEW OF APPLICATION TO SOLAR-ENERGY COLLECTION [J].
BUCHBERG, H ;
CATTON, I ;
EDWARDS, DK .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1976, 98 (02) :182-188
[6]  
CHAUDHURI TK, 1998, SESI J, V8, P1
[7]   Thermal performance of a box-type solar cooker with outer-inner reflectors [J].
ElSebaii, AA .
ENERGY, 1997, 22 (10) :969-978
[8]   WIND-RELATED HEAT-LOSSES OF A FLAT-PLATE COLLECTOR [J].
FRANCEY, JLA ;
PAPAIOANNOU, J .
SOLAR ENERGY, 1985, 35 (01) :15-19
[9]   THE TOP LOSS CALCULATION FOR FLAT-PLATE SOLAR COLLECTORS [J].
GARG, HP ;
DATTA, G .
SOLAR ENERGY, 1984, 32 (01) :141-143
[10]   FREE CONVECTIVE HEAT-TRANSFER ACROSS INCLINED AIR LAYERS [J].
HOLLANDS, KGT ;
UNNY, TE ;
RAITHBY, GD ;
KONICEK, L .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1976, 98 (02) :189-193