Direct Identification of Urinary Tract Pathogens from Urine Samples by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry

被引:236
作者
Ferreira, Laura [2 ]
Sanchez-Juanes, Fernando [2 ]
Gonzalez-Avila, Magdalena [1 ]
Cembrero-Fucinos, David [3 ]
Herrero-Hernandez, Ana [1 ]
Manuel Gonzalez-Buitrago, Jose [2 ,4 ]
Luis Munoz-Bellido, Juan [1 ,5 ]
机构
[1] Hosp Univ Salamanca, Dept Microbiol, Salamanca 37007, Spain
[2] Hosp Univ Salamanca, Unidad Invest, Salamanca 37007, Spain
[3] Hosp Univ Salamanca, Serv Anal Clin, Salamanca 37007, Spain
[4] Univ Salamanca, Dept Bioquim & Biol Mol, E-37008 Salamanca, Spain
[5] Univ Salamanca, Dept Med Prevent Salud Publ & Microbiol Med, E-37008 Salamanca, Spain
关键词
SPECIES IDENTIFICATION; INFECTION; BACTERIA;
D O I
10.1128/JCM.02215-09
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been suggested as a reliable method for bacterial identification from cultures. Direct analysis of clinical samples might increase the usefulness of this method, shortening the time for microorganism identification. We compared conventional methods for the diagnosis of urinary tract infections (UTIs) and identification of the urinary tract pathogens (automated screening, plate cultures, and identification based on biochemical characteristics) and a fast method based on conventional screening and MALDI-TOF MS. For this latter method, 4 ml of urine was centrifuged at a low-revolution setting (2,000 x g) to remove leukocytes and then at high revolutions (15,500 x g) to collect bacteria. The pellet was washed and then applied directly to the MALDI-TOF MS plate. Two hundred sixty urine samples, detected as positive by the screening device (UF-1000i), were processed by culture and MALDI-TOF MS. Twenty samples were positive in the screening device but negative in culture, and all of them were also negative by MALDI-TOF MS. Two-hundred thirty-five samples displayed significant growth of a single morphological type in culture. Two-hundred twenty of them showed bacterial growth of >10(5) CFU/ml. Microorganism identifications in this group were coincident at the species level in 202 cases (91.8%) and at the genus level in 204 cases (92.7%). The most frequent microorganism was Escherichia coli (173 isolates). MALDI-TOF MS identified this microorganism directly from the urine sample in 163 cases (94.2%). Our results show that MALDI-TOF MS allows bacterial identification directly from infected urine in a short time, with high accuracy, and especially when Gram-negative bacteria with high bacterial counts are involved.
引用
收藏
页码:2110 / 2115
页数:6
相关论文
共 14 条
[1]   Rapid identification and typing of Listeria species by matrix-assisted laser desorption ionization-time of flight mass spectrometry [J].
Barbuddhe, Sukhadeo B. ;
Maier, Thomas ;
Schwarz, Gerold ;
Kostrzewa, Markus ;
Hof, Herbert ;
Domann, Eugen ;
Chakraborty, Trinad ;
Hain, Torsten .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2008, 74 (17) :5402-5407
[2]  
BLONDIAUX N, 2009, PATHOL BIOL PARIS
[3]   Matrix-assisted laser desorption ionization-time of flight mass spectrometry for identification of nonfermenting gram-negative bacilli isolated from cystic fibrosis patients [J].
Degand, Nicolas ;
Carbonnelle, Etienne ;
Dauphin, Brunhilde ;
Beretti, Jean-Luc ;
Le Bourgeois, Muriel ;
Sermet-Gaudelus, Isabelle ;
Segonds, Christine ;
Berche, Patrick ;
Nassif, Xavier ;
Ferroni, Agnes .
JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (10) :3361-3367
[4]   The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy [J].
Devillé W.L.J.M. ;
Yzermans J.C. ;
Van Duijn N.P. ;
Bezemer P.D. ;
Van Der Windt D.A.W.M. ;
Bouter L.M. .
BMC Urology, 4 (1) :1-14
[5]   Rapid Classification and Identification of Salmonellae at the Species and Subspecies Levels by Whole-Cell Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry [J].
Dieckmann, Ralf ;
Helmuth, Reiner ;
Erhard, Marcel ;
Malorny, Burkhard .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2008, 74 (24) :7767-7778
[6]   Characterization of intact microorganisms by MALDI mass spectrometry [J].
Fenselau, C ;
Demirev, PA .
MASS SPECTROMETRY REVIEWS, 2001, 20 (04) :157-171
[7]   Urinary tract infection: Self reported incidence and associated costs [J].
Foxman, B ;
Barlow, R ;
D'Arcy, H ;
Gillespie, B ;
Sobel, JD .
ANNALS OF EPIDEMIOLOGY, 2000, 10 (08) :509-515
[8]   Challenging the problem of clostridial identification with matrix-assisted laser desorption and ionization-time-of-flight mass spectrometry (MALDI-TOF MS) [J].
Grosse-Herrenthey, Anke ;
Maier, Thomas ;
Gessler, Frank ;
Schaumann, Reiner ;
Boehnel, Helge ;
Kostrzewa, Markus ;
Krueger, Monika .
ANAEROBE, 2008, 14 (04) :242-249
[9]   Diagnosis and treatment of uncomplicated urinary tract infection [J].
Hooton, TM ;
Stamm, WE .
INFECTIOUS DISEASE CLINICS OF NORTH AMERICA, 1997, 11 (03) :551-+
[10]   Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Fast and Reliable Identification of Clinical Yeast Isolates [J].
Marklein, G. ;
Josten, M. ;
Klanke, U. ;
Mueller, E. ;
Horre, R. ;
Maier, T. ;
Wenzel, T. ;
Kostrzewa, M. ;
Bierbaum, G. ;
Hoerauf, A. ;
Sahl, H. -G. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (09) :2912-2917