Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolution

被引:340
作者
Jerosch-Herold, M
Wilke, N
Stillman, AE
Wilson, RF
机构
[1] Univ Minnesota, Dept Radiol, Sch Med, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Sch Med, Dept Med, Minneapolis, MN 55455 USA
关键词
magnetic resonance; myocardium; blood flow reserve; MR contrast agents;
D O I
10.1118/1.598163
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The myocardial perfusion reserve, defined as the ratio of hyperemic and basal myocardial blood flow, is a useful indicator of the functional significance of a coronary artery lesion. Rapid magnetic resonance (MR) imaging for the noninvasive detection of a bolus-injected contrast agent as a MR tracer is applied to the measurement of regional tissue perfusion during rest and hyperemia, in patients with microvascular dysfunction. A Fermi function model for the distribution of tracer residence times in the myocardium is used to fit the MR signal curves. The myocardial perfusion reserve is calculated from the impulse response amplitudes for rest and hyperemia. The assumptions of the model are tested with Monte Carlo simulations, using a multiple path, axially distributed mathematical model of blood tissue exchange, which allows for systematic variation of blood flow, vascular volume, and capillary permeability. For a contrast-to-noise ratio of 6:1, and over a range of hows from 0.5 to 4.0 ml/min per g of tissue, the ratio of the impulse response amplitudes for hyperemic and basal Rows is linearly proportional to the ratio of model blood flows, if the mean transit time of the input function is shorter than approximately 9 s. The uncertainty in the blood flow reserve estimates grows both at low (< 1.0 ml/min/g) and high (> 3-4 ml/min/g) flows. The predictions of the Monte Carlo simulations agree with the results of MR first pass studies in patients without significant coronary artery lesions and microvascular dysfunction, where the perfusion reserve in the territory of the left anterior descending coronary artery (LAD) correlates linearly with the intracoronary Doppler ultrasound flow reserve in the LAD (r = 0.84), in agreement with previous PET studies. (C) 1998 American Association of Physicists in Medicine.
引用
收藏
页码:73 / 84
页数:12
相关论文
共 41 条
[1]   TISSUE MEAN TRANSIT-TIME FROM DYNAMIC COMPUTED-TOMOGRAPHY BY A SIMPLE DECONVOLUTION TECHNIQUE [J].
AXEL, L .
INVESTIGATIVE RADIOLOGY, 1983, 18 (01) :94-99
[2]  
BASSINGTHWAIGHT.JB, 1984, HDB PHYSL CARDIOVASC
[3]  
BASSINGTHWAIGTH.JB, 1993, NUCL CARDIOLOGY STAT
[4]   FAST AND PRECISE T1 IMAGING USING A TOMROP SEQUENCE [J].
BRIX, G ;
SCHAD, LR ;
DEIMLING, M ;
LORENZ, WJ .
MAGNETIC RESONANCE IMAGING, 1990, 8 (04) :351-356
[5]   REGIONAL MYOCARDIAL FLOW AND CAPILLARY PERMEABILITY-SURFACE AREA PRODUCTS ARE NEARLY PROPORTIONAL [J].
CALDWELL, JH ;
MARTIN, GV ;
RAYMOND, GM ;
BASSINGTHWAIGHTE, JB .
AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 267 (02) :H654-H666
[6]   MEASUREMENT OF ABSOLUTE EPICARDIAL CORONARY-ARTERY FLOW AND FLOW RESERVE WITH BREATH-HOLD CINE PHASE-CONTRAST MAGNETIC-RESONANCE-IMAGING [J].
CLARKE, GD ;
ECKELS, R ;
CHANEY, C ;
SMITH, D ;
DITTRICH, J ;
HUNDLEY, WG ;
NESSAIVER, M ;
LI, HF ;
PARKEY, RW ;
PESHOCK, RM .
CIRCULATION, 1995, 91 (10) :2627-2634
[7]   REGIONAL TRANSIT-TIME ESTIMATION FROM IMAGE RESIDUE CURVES [J].
CLOUGH, AV ;
ALTINAWI, A ;
LINEHAN, JH ;
DAWSON, CA .
ANNALS OF BIOMEDICAL ENGINEERING, 1994, 22 (02) :128-143
[8]   SMALL VESSEL AND TOTAL CORONARY BLOOD-VOLUME DURING INTRA-CORONARY ADENOSINE [J].
CRYSTAL, GJ ;
DOWNEY, HF ;
BASHOUR, FA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1981, 241 (02) :H194-H201
[9]   DIGITAL SUBTRACTION ANGIOGRAPHIC IMAGING OF CORONARY FLOW RESERVE [J].
CUSMA, JT ;
TOGGART, EJ ;
FOLTS, JD ;
PEPPLER, WW ;
HANGIANDREOU, NJ ;
LEE, CS ;
MISTRETTA, CA .
CIRCULATION, 1987, 75 (02) :461-472
[10]   Improving MR quantification of regional blood volume with intravascular T-1 contrast agents: Accuracy, precision, and water exchange [J].
Donahue, KM ;
Weisskoff, RM ;
Chesler, DA ;
Kwong, KK ;
Bogdanov, AA ;
Mandeville, JB ;
Rosen, BR .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :858-867