Comparative study of pathological lesions induced by multiwalled carbon nanotubes in lungs of mice by intratracheal instillation and inhalation

被引:120
作者
Li, Jun-Gang
Li, Wen-Xin
Xu, Jing-Ying
Cai, Xiao-Qing
Liu, Rui-Li
Li, Yong-Jun
Zhao, Qun-Fen
Li, Qing-Nuan [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
[2] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
[3] Ningbo Univ, Coll Life Sci & Bioengn, Ningbo 315211, Peoples R China
关键词
multiwalled carbon nanotubes; aerosol; intratracheal instillation; inhalation; pathological lesions; toxicity;
D O I
10.1002/tox.20270
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The pathological lesions induced by multiwalled carbon nanotubes (MWCNTs) in bronchi and alveoli of mice were studied by intratracheal instillation and inhalation. In instillation groups, the dose was 0.05 mg MWCNTs/mouse. Similar size clumps of MWCNTs were distributed in bronchi and alveoli. The clumps led to inflammation to the lining wall of bronchi and severe destruction to alveolar netted structure around them. In the inhalation groups, the mice were exposed to aerosolized MWCNTs with mean concentration of 32.61 mg/m(3), the intralung deposition dose were roughly 0.07, 0.14, and 0.21 mg in the 8-day group, 16-day group, and 24-day group, respectively. Most of aggregations of MWCNTs in the alveoli were smaller than that in bronchi. The aggregations induced proliferation and thickening of alveolar walls. With the exception of these moderate pathological lesions, the general alveolar structure was still remained. The preliminary study demonstrated a difference in lung pathological lesions induced by instilled MWCNTs and inhaled ones, which may be due to the different size and distribution of aggregations of MWCNTs in lung. (C) 2007 Wiley Periodicals, Inc. Environ Toxicol 22: 415-421, 2007.
引用
收藏
页码:415 / 421
页数:7
相关论文
共 17 条
[1]   Roll up for the revolution [J].
Ball, P .
NATURE, 2001, 414 (6860) :142-144
[2]   The potential environmental impact of engineered nanomaterials [J].
Colvin, VL .
NATURE BIOTECHNOLOGY, 2003, 21 (10) :1166-1170
[3]   Carbon nanotubes: A review of their properties in relation to pulmonary toxicology and workplace safety [J].
Donaldson, Ken ;
Aitken, Robert ;
Tran, Lang ;
Stone, Vicki ;
Duffin, Rodger ;
Forrest, Gavin ;
Alexander, Andrew .
TOXICOLOGICAL SCIENCES, 2006, 92 (01) :5-22
[4]   Intratracheal instillation as an exposure technique for the evaluation of respiratory tract toxicity: Uses and limitations [J].
Driscoll, KE ;
Costa, DL ;
Hatch, G ;
Henderson, R ;
Oberdorster, G ;
Salem, H ;
Schlesinger, RB .
TOXICOLOGICAL SCIENCES, 2000, 55 (01) :24-35
[5]   Toxicology of carbon nanomaterials: Status, trends, and perspectives on the special issue [J].
Hurt, RH ;
Monthioux, M ;
Kane, A .
CARBON, 2006, 44 (06) :1028-1033
[6]   A review of carbon nanotube toxicity and assessment of potential occupational and environmental health risks [J].
Lam, CW ;
James, JT ;
McCluskey, R ;
Arepalli, S ;
Hunter, RL .
CRITICAL REVIEWS IN TOXICOLOGY, 2006, 36 (03) :189-217
[7]   Pulmonary toxicity of single-wall carbon nanotubes in mice 7 and 90 days after intratracheal instillation [J].
Lam, CW ;
James, JT ;
McCluskey, R ;
Hunter, RL .
TOXICOLOGICAL SCIENCES, 2004, 77 (01) :126-134
[8]   Exposure to carbon nanotube material: Aerosol release during the handling of unrefined single-walled carbon nanotube material [J].
Maynard, AD ;
Baron, PA ;
Foley, M ;
Shvedova, AA ;
Kisin, ER ;
Castranova, V .
JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART A-CURRENT ISSUES, 2004, 67 (01) :87-107
[9]   Respiratory toxicity of carbon nanotubes: How worried should we be? [J].
Muller, J ;
Huaux, F ;
Lison, D .
CARBON, 2006, 44 (06) :1048-1056
[10]   Respiratory toxicity of multi-wall carbon nanotubes [J].
Muller, J ;
Huaux, F ;
Moreau, N ;
Misson, P ;
Heilier, JF ;
Delos, M ;
Arras, M ;
Fonseca, A ;
Nagy, JB ;
Lison, D .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 2005, 207 (03) :221-231