Tracking lung tissue motion and expansion/compression with inverse consistent image registration and spirometry

被引:97
作者
Christensen, Gary E. [1 ]
Song, Joo Hyun
Lu, Wei
El Naqa, Issarn
Low, Daniel A.
机构
[1] Univ Iowa, Dept Elect & Comp Engn, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Radiat Oncol, Iowa City, IA 52242 USA
[3] Washington Univ, Sch Med, Dept Radiat Oncol, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
关键词
image registration; radiation therapy; lung motion; inverse consistency;
D O I
10.1118/1.2731029
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Breathing motion is one of the major limiting factors for reducing dose and irradiation of normal tissue for conventional conformal radiotherapy. This paper describes a relationship between tracking lung motion using spirometry data and image registration of consecutive CT image volumes collected from a multislice CT scanner over multiple breathing periods. Temporal CT sequences from 5 individuals were analyzed in this study. The couch was moved from 11 to 14 different positions to image the entire lung. At each couch position, 15 image volumes were collected over approximately 3 breathing periods. It is assumed that the expansion and contraction of lung tissue can be modeled as an elastic material. Furthermore, it is assumed that the deformation of the lung is small over one-fifth of a breathing period and therefore the motion of the lung can be adequately modeled using a small deformation linear elastic model. The small deformation inverse consistent linear elastic image registration algorithm is therefore well suited for this problem and was used to register consecutive image scans. The pointwise expansion and compression of lung tissue was measured by computing the Jacobian of the transformations used to register the images. The logarithm of the Jacobian was computed so that expansion and compression of the lung were scaled equally. The log-Jacobian was computed at each voxel in the volume to produce a map of the local expansion and compression of the lung during the breathing period. These log-Jacobian images demonstrate that the lung does not expand uniformly during the breathing period, but rather expands and contracts locally at different rates during inhalation and exhalation. The log-Jacobian numbers were averaged over a cross section of the lung to produce an estimate of the average expansion or compression from one time point to the next and compared to the air flow rate measured by spirometry. In four out of five individuals, the average log-Jacobian value and the air flow rate correlated well (R-2 = 0.858 on average for the entire lung). The correlation for the fifth individual was not as good (R-2 = 0.377 on average for the entire lung) and can be explained by the small variation in tidal volume for this individual. The correlation of the average log-Jacobian value and the air flow rate for images near the diaphragm correlated well in all five individuals (R-2 = 0.943 on average). These preliminary results indicate a strong correlation between the expansion/ compression of the lung measured by image registration and the air flow rate measured by spirometry. Predicting the location, motion, and compression/expansion of the tumor and normal tissue using image registration and spirometry could have many important benefits for radiotherapy treatment. These benefits include reducing radiation dose to normal tissue, maximizing dose to the tumor, improving patient care, reducing treatment cost, and increasing patient throughput. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:2155 / 2163
页数:9
相关论文
共 36 条
[1]
Intensity-modulated radiotherapy: Current status and issues of interest [J].
Boyer, AL ;
Butler, EB ;
DiPetrillo, TA ;
Engler, MJ ;
Fraass, B ;
Grant, W ;
Ling, CC ;
Low, DA ;
Mackie, TR ;
Mohan, R ;
Purdy, JA ;
Roach, M ;
Rosenman, JG ;
Verhey, LJ ;
Wong, JW ;
Cumberlin, RL ;
Stone, H ;
Palta, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04) :880-914
[2]
Feasibility of a novel deformable image registration technique to facilitate classification, targeting, and monitoring of tumor and normal tissue [J].
Brock, KK ;
Dawson, LA ;
Sharpe, MB ;
Moseley, DJ ;
Jaffray, DA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (04) :1245-1254
[3]
Accuracy of finite element model-based multi-organ deformable image registration [J].
Brock, KK ;
Sharpe, MB ;
Dawson, LA ;
Kim, SM ;
Jaffray, DA .
MEDICAL PHYSICS, 2005, 32 (06) :1647-1659
[4]
Buck R. C., 1978, Advanced Calculus
[5]
Butler Laura E, 2004, J Appl Clin Med Phys, V5, P16, DOI 10.1120/jacmp.26.146
[6]
Cardenas Alex, 2004, J Appl Clin Med Phys, V5, P55, DOI 10.1120/jacmp.2021.25276
[7]
Invertibility and transitivity analysis for nonrigid image registration [J].
Christensen, GE ;
Johnson, HJ .
JOURNAL OF ELECTRONIC IMAGING, 2003, 12 (01) :106-117
[8]
Consistent image registration [J].
Christensen, GE ;
Johnson, HJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (07) :568-582
[9]
Christensen GE, 1999, LECT NOTES COMPUT SC, V1613, P224
[10]
CHRISTENSEN GE, P 14 INT C US COMP R, P493