Determination of naphthalenesulfonates in water by on-line ion-pair solid-phase extraction and ion-pair liquid chromatography with fast-scanning fluorescence detection

被引:30
作者
Gimeno, RA
Beltrán, JL
Marcé, RM
Borrull, F
机构
[1] Univ Rovira & Virgili, Dept Quim Analit & Quim Organ, Tarragona 43005, Spain
[2] Univ Barcelona, Dept Quim Analit, E-08028 Barcelona, Spain
关键词
water analysis; solid-phase extraction; partial least squares calibration; fast scanning fluorescence detection; detection; LC; naphthalenesulfonates;
D O I
10.1016/S0021-9673(00)00599-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fast analytical method for quantifying a mixture of 12 naphthalenesulfonates and naphthalenedisulfonates has been developed. This method consists of on-line ion-pair solid-phase extraction with PLRP-s sorbent and ion-pair liquid-chromatography using fast-scanning fluorescence spectrometer as a detection system and multivariate calibration. As complete separation is unnecessary, the compounds were analysed in isocratic conditions and the chromatographic analysis took only 25 min. Three-way partial least-squares (PLS) was used to carry out multivariate calibration for spiked tap water. in these conditions, quantification limits were between 0.01 and 3 mu g l(-1). Repeatability was also evaluated and relative standard deviations (n = 3) were between 0.5 and 4, depending on the compound. Finally, spiked tap and Ebro river waters were analysed to evaluate prediction capability of the method. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:289 / 294
页数:6
相关论文
共 20 条
[1]   Solid phase extraction procedure of polar benzene- and naphthalenesulfonates in industrial effluents followed by unequivocal determination with ion pair chromatography/electrospray-mass spectrometry [J].
Alonso, MC ;
Castillo, M ;
Barceló, D .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2586-2593
[2]   Ion-interaction high-performance liquid chromatography and micellar electrokinetic capillary chromatography: two complementary techniques for the separation of aromatic sulfonated compounds [J].
Angelino, S ;
Prevot, AB ;
Gennaro, MC ;
Pramauro, E .
JOURNAL OF CHROMATOGRAPHY A, 1999, 845 (1-2) :257-271
[3]   SEPARATION OF SULFONATE AND CARBOXYLATE MIXTURES BY ION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BEAR, GR ;
LAWLEY, CW ;
RIDDLE, RM .
JOURNAL OF CHROMATOGRAPHY, 1984, 302 (OCT) :65-78
[4]   Three-way multivariate calibration procedures applied to high-performance liquid chromatography coupled with fast-scanning fluorescence spectrometry detection.: Determination of polycyclic aromatic hydrocarbons in water samples [J].
Beltrán, JL ;
Guiteras, J ;
Ferrer, R .
ANALYTICAL CHEMISTRY, 1998, 70 (09) :1949-1955
[5]  
Bro R, 1996, J CHEMOMETR, V10, P47, DOI 10.1002/(SICI)1099-128X(199601)10:1<47::AID-CEM400>3.3.CO
[6]  
2-3
[7]  
BROUWER ER, 1992, ANALUSIS, V20, P121
[8]   Comparative study of capillary zone electrophoresis and micellar electrokinetic chromatography for the separation of twelve aromatic sulphonate compounds [J].
Cugat, MJ ;
Borrull, F ;
Calull, M .
CHROMATOGRAPHIA, 1997, 46 (3-4) :204-208
[9]  
El Harrak R, 1998, INT J ENVIRON AN CH, V69, P295
[10]  
ELHARRAK R, 1997, QUIM ANAL S2, V16, pS251