Percutaneous removal of malignant mammographic lesions at stereotactic vacuum-assisted biopsy

被引:77
作者
Liberman, L
Dershaw, DD
Rosen, PP
Morris, EA
Abramson, AF
Borgen, PV
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Radiol, New York, NY 10021 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Pathol, New York, NY 10021 USA
[3] Mem Sloan Kettering Canc Ctr, Dept Surg, New York, NY 10021 USA
关键词
breast; biopsy; breast neoplasms; diagnosis; stereotaxis;
D O I
10.1148/radiology.206.3.9494489
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine whether complete percutaneous removal of a malignant lesion detected at mammography ensures complete excision of the carcinoma histopathologically. MATERIALS AND METHODS: A retrospective review was performed of 135 lesions in which stereotactic biopsy was performed with a directional, vacuum biopsy instrument and an 11-gauge probe followed by mammography. Carcinoma was diagnosed at stereotactic biopsy in 51 (38%) lesions. In 15 (29%) carcinomas, the lesion seen at mammography was removed at stereotactic biopsy. Surgical findings were available for correlation with biopsy and imaging findings in all 15 cases. Mammographic and histopathologic findings were reviewed. RESULTS: Mammographic findings were calcifications in 11 lesions and a mass in four lesions. The median lesion size was 0.7 cm (range, 0.2-1.4 cm), and the median number of biopsy specimens was 15 (range, 10-22 specimens). Histopathologic findings at stereotactic biopsy were ductal carcinoma in situ in 12 lesions and infiltrating ductal carcinoma in three. Surgery revealed residual carcinoma in 11 (73%) of 15 lesions, including all three infiltrating ductal carcinomas and eight of 12 ductal carcinoma in situ lesions. CONCLUSION: Complete removal of the mammographic lesion does not ensure complete excision of the carcinoma.
引用
收藏
页码:711 / 715
页数:5
相关论文
共 35 条
[1]   Lymphatic mapping and sentinel node biopsy in the patient with breast cancer [J].
Albertini, JJ ;
Lyman, GH ;
Cox, C ;
Yeatman, T ;
Balducci, L ;
Ku, NN ;
Shivers, S ;
Berman, C ;
Wells, K ;
Rapaport, D ;
Shons, A ;
Horton, J ;
Greenberg, H ;
Nicosia, S ;
Clark, R ;
Cantor, A ;
Reintgen, DS .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (22) :1818-1822
[3]   Stereotactic core-needle biopsy of the breast: A report of the joint task force of the American College of Radiology, American College of Surgeons, and College of American Pathologists [J].
Bassett, L ;
Winchester, DP ;
Caplan, RB ;
Dershaw, DD ;
Dowlatshahi, K ;
Evans, WP ;
Fajardo, LL ;
Fitzgibbons, PL ;
Henson, DE ;
Hutter, RVP ;
Morrow, M ;
Paquelet, JR ;
Singletary, SE ;
Curry, J ;
WilcoxBuchalla, P ;
Zinninger, M .
CA-A CANCER JOURNAL FOR CLINICIANS, 1997, 47 (03) :171-+
[4]   Intradermal blue dye to identify sentinel lymphnode in breast cancer [J].
Borgstein, PJ ;
Meijer, S ;
Pijpers, R .
LANCET, 1997, 349 (9066) :1668-1669
[5]   Mammographic findings after 14-gauge automated needle and 14-gauge directional, vacuum-assisted stereotactic breast biopsies [J].
Burbank, F .
RADIOLOGY, 1997, 204 (01) :153-156
[6]  
Burbank F, 1996, AM SURGEON, V62, P738
[7]   Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: Improved accuracy with directional, vacuum-assisted biopsy [J].
Burbank, F .
RADIOLOGY, 1997, 202 (03) :843-847
[8]   Tissue marking clip for stereotactic breast biopsy: Initial placement accuracy, long-term stability, and usefulness as a guide for wire localization [J].
Burbank, F ;
Forcier, N .
RADIOLOGY, 1997, 205 (02) :407-415
[9]  
BURBANK F, 1996, MINI INVASIVE THER S, V5, P39
[10]  
EVANS WP, 1997, AJR S, V168, P96