Bioactive polymer grafting onto titanium alloy surfaces

被引:64
作者
Michiardi, A. [2 ]
Helary, G. [1 ]
Nguyen, P. -C. T. [3 ,4 ]
Gamble, L. J. [3 ,4 ]
Anagnostou, F. [5 ]
Castner, D. G. [3 ,4 ]
Migonney, V. [1 ]
机构
[1] Univ Paris 13, Inst Galilee, CNRS, FRE 3043,CSPBAT,LBPS, F-93430 Villetaneuse, France
[2] IBEC, Barcelona, Spain
[3] Univ Washington, Dept Bioengn, Natl ESCA & Surface Anal Ctr Biomed Problems, Seattle, WA 98195 USA
[4] Univ Washington, Dept Chem Engn, Natl ESCA & Surface Anal Ctr Biomed Problems, Seattle, WA 98195 USA
[5] Univ Paris 07, CNRS, UMR 7052, F-75010 Paris, France
基金
美国国家卫生研究院;
关键词
Titanium alloy; Bioactive polymers; Osteointegration; ToF-SIMS; XPS; CHEMICAL-CHARACTERIZATION; CALCIUM-PHOSPHATE; DENSE HA; IMPLANTS; COATINGS; SIMS; SULFONATE; ACID; XPS;
D O I
10.1016/j.actbio.2009.08.043
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Bioactive polymers bearing sulfonate (styrene sodium sulfonate, NaSS) and carboxylate (methylacrylic acid, MA) groups were grafted onto Ti6Al4V alloy surfaces by a two-step procedure. The Ti alloy surfaces were first chemically oxidized in a piranha solution and then directly subjected to radical polymerization at 70 degrees C in the absence of oxygen. The grafted surfaces were characterized by X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (ToF-SIMS) and the toluidine blue colorimetric method. Toluidine blue results showed 1-5 mu g cm(-2) of polymer was grafted onto the oxidized Ti surfaces. Grafting resulted in a decrease in the XPS Ti and 0 signals from the underlying Ti substrate and a corresponding increase in the XPS C and S signals from the polymer layer. The ToF-SIMS intensities of the S- and SO- ions correlated linearly with the XPS atomic percent S concentrations and the ToF-SIMS intensity of the TiO3H2- ion correlated linearly with the XPS atomic per cent Ti concentration. Thus, the ToF-SIMS S- SO- and TiO3H2- intensities can be used to quantify the composition and amount of grafted polymer. ToF-SIMS also detected ions that were more characteristic of the polymer molecular structure (C6H4SO3- and C8H7SO3- from NaSS, C4H5O2- from MA), but the intensity of these peaks depended on the polymer thickness and composition. An in vitro cell culture test was carried out with human osteoblast-like cells to assess the influence of the grafted polymers on cell response. Cell adhesion after 30 min of incubation showed significant differences between the grafted and ungrafted surfaces. The NaSS grafted surfaces showed the highest degree of cell adhesion while the MA-NaSS grafted surfaces showed the lowest degree of cell adhesion. After 4 weeks in vivo in rabbit femoral bones, bone was observed to be in direct contact with all implants. The percentage of mineralized tissue around the implants was similar for NaSS grafted and non-grafted implants (59% and 57%). The MA-NaSS grafted implant exhibited a lower amount of mineralized tissue (47%). (C) 2009 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:667 / 675
页数:9
相关论文
共 39 条
[1]
BREME J, 1989, REV METALLURGIE, V10, P625
[3]
STATIC SECONDARY ION MASS-SPECTROMETRY AND X-RAY PHOTOELECTRON-SPECTROSCOPY OF DEUTERIUM-SUBSTITUTED AND METHYL-SUBSTITUTED POLYSTYRENE [J].
CHILKOTI, A ;
CASTNER, DG ;
RATNER, BD .
APPLIED SPECTROSCOPY, 1991, 45 (02) :209-217
[4]
Radical graft polymerization of styrene sulfonate on poly(ethylene terephthalate) films for ACL applications: "Grafting from" and chemical characterization [J].
Ciobanu, M ;
Siove, A ;
Gueguen, V ;
Gamble, LJ ;
Castner, DG ;
Migonney, V .
BIOMACROMOLECULES, 2006, 7 (03) :755-760
[5]
Surface chemical characterization using XPS and ToF-SIMS of latex particles prepared by the emulsion copolymerization of methacrylic acid and styrene [J].
Davies, MC ;
Lynn, RAP ;
Hearn, J ;
Paul, AJ ;
Vickerman, JC ;
Watts, JF .
LANGMUIR, 1996, 12 (16) :3866-3875
[6]
Ion implantation:: surface treatment for improving the bone integration of titanium and Ti6Al4V dental implants [J].
de Maeztu, MA ;
Alava, JI ;
Gay-Escoda, C .
CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (01) :57-62
[7]
PLASMA SPRAYED COATINGS OF HYDROXYLAPATITE [J].
DEGROOT, K ;
GEESINK, R ;
KLEIN, CPAT ;
SEREKIAN, P .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1987, 21 (12) :1375-1381
[8]
Deng C, 2007, J IRON STEEL RES INT, V14, P73
[9]
Comparative study of silanisation reactions for the biofunctionalisation of Ti-surfaces [J].
Dubruel, P. ;
Vanderleyden, E. ;
Bergada, M. ;
De Paepe, I. ;
Chen, H. ;
Kuypers, S. ;
Luyten, J. ;
Schrooten, J. ;
Van Hoorebeke, L. ;
Schacht, E. .
SURFACE SCIENCE, 2006, 600 (12) :2562-2571
[10]
Physics of hydroxyapatite plasma coatings on TiNi shape memory materials [J].
Filip, P ;
Kneissl, AC ;
Mazanec, K .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1997, 234 :422-425