An experimental study of wind-driven cross ventilation in partitioned buildings

被引:43
作者
Chu, Chia Ren [1 ]
Chiu, Y. -H. [2 ]
Wang, Yu-Wen [1 ]
机构
[1] Natl Cent Univ, Dept Civil Engn, Tao Yuan 32001, Taiwan
[2] Chinese Culture Univ, Dept Architecture & Urban Design, Taipei, Taiwan
关键词
Natural ventilation; Partition; Discharge coefficient; Wind tunnel; MULTIZONE AIR-FLOW; NATURAL VENTILATION; COMIS; SIMULATION; TRANSPORT; MODEL;
D O I
10.1016/j.enbuild.2009.11.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study uses wind tunnel experiments to investigate wind-driven cross ventilation in partitioned buildings. The discharge coefficients of internal opening under various flow conditions were determined by a fan technique. It was found that the internal discharge coefficient is dependent on the internal porosity, but independent of external porosity, and opening location. Based on the experimental results, a predictive model for internal pressure and ventilation rate of multi-room buildings was developed and verified. This model also revealed that the ventilation rate increases as the internal porosity increases, and that the maximum ventilation rate occurs when the windward and leeward opening areas are equal. Because internal partitions reduce the difference between external and internal pressure, the ventilation rate of partitioned buildings is always smaller than that of buildings without partition. Furthermore, this study provides a quantitative scheme to regulate the ventilation rate of partitioned buildings by controlling the opening areas of windward, leeward and internal openings. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:667 / 673
页数:7
相关论文
共 25 条
[1]  
ANSI/AMCA, 1999, 21099 ANSIAMCA
[2]  
AWBI HB, 1991, VENTILATION BUILDING, P61
[3]  
AXLEY JW, 2006, BUILDING VENTILATION, P39
[4]  
AYNSLEY RM, 1997, ARCHITECTURAL AERODY, P192
[5]   Numerical investigation of airflow pattern and particulate matter transport in naturally ventilated multi-room buildings [J].
Chang, TJ ;
Hsieh, YF ;
Kao, HM .
INDOOR AIR, 2006, 16 (02) :136-152
[6]   Ventilation performance prediction for buildings: A method overview and recent applications [J].
Chen, Qingyan .
BUILDING AND ENVIRONMENT, 2009, 44 (04) :848-858
[7]   External flow effects on the discharge coefficients of two types of ventilation opening [J].
Chiu, Y-H. ;
Etheridge, D. W. .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2007, 95 (04) :225-252
[8]   Turbulence effects on the discharge coefficient and mean flow rate of wind-driven cross-ventilation [J].
Chu, Chia R. ;
Chiu, Y. -H ;
Chen, Yan-Jhih ;
Wang, Yu-Wen ;
Chou, C-P .
BUILDING AND ENVIRONMENT, 2009, 44 (10) :2064-2072
[9]   Modeling large openings with COMIS [J].
Dascalaki, E ;
Santamouris, M ;
Bruant, M ;
Balaras, CA ;
Bossaer, A ;
Ducarme, D ;
Wouters, P .
ENERGY AND BUILDINGS, 1999, 30 (01) :105-115
[10]  
Etheridge DW., 1996, Building ventilation: theory and measurement