Size of emptied plaque cavity following spontaneous rupture is related to coronary dimensions, not to the degree of lumen narrowing. A study with intravascular ultrasound in vivo

被引:17
作者
von Birgelen, C
Klinkhart, W
Mintz, GS
Wieneke, H
Baumgart, D
Haude, M
Bartel, T
Sack, S
Ge, J
Erbel, R
机构
[1] Univ Hosp Essen, Dept Cardiol, D-45122 Essen, Germany
[2] Washington Hosp Ctr, Washington, DC 20010 USA
关键词
intravascular ultrasound; ultrasonic scanning; plaque rupture; remodelling;
D O I
10.1136/heart.84.5.483
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To identify any potential relations between the size of an emptied plaque cavity and the remodelling pattern, plaque or vessel dimensions, lumen narrowing, and other ultrasonic lesion characteristics. Design-Intravascular ultrasound was used to examine prospectively 51 ruptured ulcerated coronary plaques. Cross sectional area measurements comprised lumen, vessel, plaque, and emptied plaque cavity. Lumen narrowing was calculated as 1 - (lesion lumen area/reference lumen area) x 100%. A remodelling index was calculated as lesion vessel area/reference vessel area, and plaques were divided into those with values > 1.05 (group A) and less than or equal to 1.05 (group B). Results-Of the total of 51 plaques, 36 (71%) were assigned to group A and 15 (29%) to group B. In neither group was there a significant difference in reference dimensions and lumen narrowing. However, lesion vessel (mean (SD): 22.6 (8.1) mm(2) v 17.5 (4.3) mm(2); p = 0.006) and plaque areas (15.8 (6.2) mm(2) v 12.8 (3.2) mm(2); p = 0.03) were greater in group A than in group B. The cavity inside the plaque was larger in group A than in group B (2.8 (1.6) mm(2) v 1.8 (0.9) mm(2); p = 0.007) and showed a positive linear relation with lesion and reference vessel size (r = 0.58 and 0.56, respectively; p < 0.001), but not with lumen narrowing. Conclusions-The size of the emptied cavity inside ruptured plaques is on average larger in lesions with adaptive vascular remodelling, and shows a linear relation with lesion plaque and vessel size and with the reference dimensions, but not with the degree of lumen narrowing.
引用
收藏
页码:483 / 488
页数:6
相关论文
共 38 条
[1]  
Baroldi G, 1988, Am J Cardiovasc Pathol, V2, P159
[2]   ACUTE PLAQUE RUPTURE AND MYOCARDIAL STUNNING IN PATIENT WITH NORMAL CORONARY ARTERIOGRAPHY [J].
BAUMGART, D ;
LIU, FQ ;
HAUDE, M ;
GORGE, G ;
GE, JB ;
ERBEL, R .
LANCET, 1995, 346 (8968) :193-194
[3]  
BOCKSCH WG, 1994, CORONARY ARTERY DIS, V5, P727
[4]  
DAVIES MJ, 1990, CIRCULATION, V82, P38
[5]   THROMBOSIS AND ACUTE CORONARY-ARTERY LESIONS IN SUDDEN CARDIAC ISCHEMIC DEATH [J].
DAVIES, MJ ;
THOMAS, A .
NEW ENGLAND JOURNAL OF MEDICINE, 1984, 310 (18) :1137-1140
[6]   Clinical application and image interpretation in intracoronary ultrasound [J].
Di Mario, C ;
Gorge, G ;
Peters, R ;
Kearney, P ;
Pinto, F ;
Hausmann, D ;
von Birgelen, C ;
Colombo, A ;
Mudra, H ;
Roelandt, J ;
Erbel, R .
EUROPEAN HEART JOURNAL, 1998, 19 (02) :207-229
[7]   Intravascular ultrasound classification of atherosclerotic lesions according to American Heart Association recommendation [J].
Erbel, R ;
Ge, JB ;
Görge, G ;
Baumgart, D ;
Haude, M ;
Jeremias, A ;
von Birgelen, C ;
Jollet, N ;
Schwedtmann, J .
CORONARY ARTERY DISEASE, 1999, 10 (07) :489-499
[8]  
FALK E, 1992, CIRCULATION, V86, P30
[9]  
FALK E, 1983, BRIT HEART J, V50, P127
[10]  
FALK E, 1995, CIRCULATION, V92, P656