Effect of flow competition on internal thoracic artery graft: Postoperative velocimetric and angiographic study

被引:51
作者
Shimizu, T [1 ]
Hirayama, T [1 ]
Suesada, H [1 ]
Ikeda, K [1 ]
Ito, S [1 ]
Ishimaru, S [1 ]
机构
[1] Tokyo Med Univ, Dept Surg 2, Shinjuku Ku, Tokyo, Japan
关键词
D O I
10.1067/mtc.2000.108166
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To assess the effects of competitive blood flow on internal thoracic artery grafts, we investigated postoperative flow velocity characteristics and angiographic findings of the grafts with various grades of native coronary artery stenosis. Methods: Fifty patients who had an internal thoracic artery graft to the left anterior descending artery underwent intravascular Doppler graft velocimetry during postoperative angiography. Patients were divided into 3 groups according to the grade of native coronary stenosis: group H (28 patients), 80% stenosis or greater; group M (16 patients), 60% to 79% stenosis; and group L (6 patients), 40% to 59% stenosis. Phasic flow velocity of the grafts was measured with an intravascular Doppler ultrasound-tipped guide wire during angiography, Graft flow volume was calculated from the diameter and the average peak velocity. Results: Average peak velocity (group HI 27.1 +/- 8.6 cm/s; group M, 16.9 +/- 3.9 cm/s; group L, 7.2 +/- 3.7 cm/s), distal graft diameter (group H, 2.27 +/- 0.23 mm; group M, 2.00 +/- 0.28mm; group L, 1.07 +/- 0.27 mm), and calculated graft flow volume (group H, 33.1 +/- 12.0 mL/min; group M, 16.2 +/- 5.8 mL/min; group L, 2.3 +/- 2.0 mL/min) significantly differed among the 3 groups. Graft flow in diastole and systole also differed among the 3 groups. Conclusions: Competitive blood flow reduces internal thoracic artery graft flow and diameter according to the grade of the native coronary artery stenosis. These data suggest that grafting the internal thoracic artery to the coronary artery with stenosis of a low grade can cause graft atrophy and failure.
引用
收藏
页码:459 / 465
页数:7
相关论文
共 29 条
[1]   Flow dynamics of angiographically no-flow patent internal mammary artery grafts [J].
Akasaka, T ;
Yoshida, K ;
Hozumi, T ;
Takagi, T ;
Kaji, S ;
Kawamoto, T ;
Morioka, S ;
Nasu, M ;
Yoshikawa, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (05) :1049-1056
[2]  
ARIS A, 1987, J THORAC CARDIOV SUR, V93, P62
[3]   QUANTITATIVE ANGIOGRAPHIC MEASUREMENTS OF ISOLATED LEFT ANTERIOR DESCENDING CORONARY-ARTERY STENOSIS - CORRELATION WITH EXERCISE ECHOCARDIOGRAPHY AND TC-99M 2-METHOXY ISOBUTYL ISONITRILE SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY [J].
ARNESE, M ;
SALUSTRI, A ;
FIORETTI, PM ;
CORNEL, JH ;
BOERSMA, E ;
REIJS, AEM ;
DEFEYTER, PJ ;
ROELANDT, JRTC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (07) :1486-1491
[4]  
BACH RG, 1993, CIRCULATION, V25, P640
[5]  
BARNER HB, 1985, J THORAC CARDIOV SUR, V90, P668
[6]   RADIAL ARTERY AND INFERIOR EPIGASTRIC ARTERY IN COMPOSITE GRAFTS - IMPROVED MIDTERM ANGIOGRAPHIC RESULTS [J].
CALAFIORE, AM ;
DIGIAMMARCO, G ;
TEODORI, G ;
DANNUNZIO, E ;
VITOLLA, G ;
FINO, C ;
MADDESTRA, N .
ANNALS OF THORACIC SURGERY, 1995, 60 (03) :517-524
[7]  
Canver CC, 1997, J CARDIOVASC SURG, V38, P211
[8]  
COSGROVE DM, 1981, J THORAC CARDIOV SUR, V82, P520
[9]  
DINCER B, 1983, J THORAC CARDIOV SUR, V85, P318
[10]   VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY [J].
DOUCETTE, JW ;
CORL, PD ;
PAYNE, HM ;
FLYNN, AE ;
GOTO, M ;
NASSI, M ;
SEGAL, J .
CIRCULATION, 1992, 85 (05) :1899-1911