Antimicrobial efficacy of a new antibiotic-loaded poly(hydroxybutyric-co-hydroxyvaleric acid) controlled release system

被引:67
作者
Rossi, S
Azghani, AO
Omri, A
机构
[1] Laurentian Univ, Dept Chem & Biochem, Sudbury, ON P3E 2C6, Canada
[2] Univ Texas Hlth Ctr, Dept Biomed Res, Tyler, TX 75708 USA
关键词
femoral implants; bacterial adhesion; gentamicin; biocompatibility; biomaterials; drug release;
D O I
10.1093/jac/dkh477
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Objective: Failure of orthopaedic devices, mainly femoral hip replacements, due to infection is of increasing medical importance. There is a need for improved antibiotic delivery systems in the treatment of orthopaedic infections and here we have evaluated polyhydroxyalkanoate formulations for their suitability as a constant delivery system for gentamicin. Methods: Gentamicin was incorporated in poly(hydroxybutyric-co-hydroxyvalerate) (PHBV) with 8% or 12% hydroxyvalerate (HV) content at 2:1 or 5:1 (weight to weight) ratio. In conjunction with an elution study, a scanning electron microscopy and a porosity study were carried out to explore physical characteristics of the complexes before and after the leaching effect. The antibacterial effectiveness of the complexes was analysed in a bacterial adhesion assay using clinical isolates of Staphylococcus haemolyticus and Staphylococcus aureus. In addition, the polymers were exposed to pooled human blood to test their biocompatibility in both static and dynamic environments. Results: We have shown that increasing the HV content from 8% to 12% leads to a faster release of the integrated antibiotic. An increase in antibiotic content enhanced the homogeneity while decreasing the permeability of the complexes and reducing the release rate. A significant reduction in the number of the adherent S. aureus and gentamicin-resistant S. haemolyticus within a 48 h exposure to our formulations confirmed the effectiveness of the PHBV/gentamicin complexes. Finally, these formulations did not alter the haemodynamics of the pooled blood samples after an extended period of time. Conclusion: Taken together, the PHBV/gentamicin formulations may prove to be effective preventive therapeutic modalities in implant-related Staphylococcus infections.
引用
收藏
页码:1013 / 1018
页数:6
相关论文
共 40 条
[1]  
ADAMS K, 1992, CLIN ORTHOP RELAT R, P244
[2]   Antibiotic susceptibility assay for Staphylococcus aureus in biofilms developed in vitro [J].
Amorena, B ;
Gracia, E ;
Monzón, M ;
Leiva, J ;
Oteiza, C ;
Pérez, M ;
Alabart, JL ;
Hernández-Yago, J .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1999, 44 (01) :43-55
[3]   BIOSYNTHESIS AND COMPOSITION OF BACTERIAL POLY(HYDROXYALKANOATES) [J].
ANDERSON, AJ ;
HAYWOOD, GW ;
DAWES, EA .
INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 1990, 12 (02) :102-105
[4]   Evaluation of the haemocompatibility of titanium based biomaterials [J].
Biehl, V ;
Wack, T ;
Winter, S ;
Seyfert, UT ;
Breme, J .
BIOMOLECULAR ENGINEERING, 2002, 19 (2-6) :97-101
[5]  
BUCHHOLZ HW, 1984, CLIN ORTHOP RELAT R, P96
[6]  
CALHOUN JH, 1993, CLIN ORTHOP RELAT R, P23
[7]   INFECTIONS ASSOCIATED WITH PROSTHETIC DEVICES - CLINICAL CONSIDERATIONS [J].
DICKINSON, GM ;
BISNO, AL .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1993, 16 (11) :749-754
[8]  
Ferreira B., 2001, MATER, V4, P34, DOI DOI 10.1590/S1516-14392001000100008
[9]   BIOMATERIAL-CENTERED INFECTION - MICROBIAL ADHESION VERSUS TISSUE INTEGRATION [J].
GRISTINA, AG .
SCIENCE, 1987, 237 (4822) :1588-1595
[10]   In vitro antibiotic release from poly(3-hydroxybutyrate-co-3-hydroxyvalerate) rods [J].
Gursel, I ;
Yagmurlu, F ;
Korkusuz, F ;
Hasirci, V .
JOURNAL OF MICROENCAPSULATION, 2002, 19 (02) :153-164