Automated Early Detection of Diabetic Retinopathy

被引:152
作者
Abramoff, Michael D. [1 ,2 ,3 ]
Reinhardt, Joseph M. [4 ]
Russell, Stephen R. [1 ,2 ]
Folk, James C. [1 ,2 ]
Mahajan, Vinit B. [1 ,4 ]
Niemeijer, Meindert [1 ,3 ,5 ]
Quellec, Gwenole [1 ,6 ]
机构
[1] Univ Iowa Hosp & Clin, Dept Ophthalmol & Visual Sci, Iowa City, IA 52242 USA
[2] Iowa City VA Med Ctr, Dept Vet Affairs, Iowa City, IA USA
[3] Univ Iowa, Dept Elect & Comp Engn, Iowa City, IA 52242 USA
[4] Univ Iowa Hosp & Clin, Omics Lab, Iowa City, IA 52242 USA
[5] Univ Utrecht, Image Sci Inst, Utrecht, Netherlands
[6] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
关键词
COLOR FUNDUS PHOTOGRAPHS; VESSEL SEGMENTATION; RED LESIONS; MICROANEURYSMS; IMAGES; OPHTHALMOSCOPY; POPULATION; PHYSICIAN; CARE;
D O I
10.1016/j.ophtha.2010.03.046
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the performance of automated diabetic retinopathy (DR) detection, using the algorithm that won the 2009 Retinopathy Online Challenge Competition in 2009, the Challenge2009, against that of the one currently used in EyeCheck, a large computer-aided early DR detection project. Design: Evaluation of diagnostic test or technology. Participants: Fundus photographic sets, consisting of 2 fundus images from each eye, were evaluated from 16 670 patient visits of 16 670 people with diabetes who had not previously been diagnosed with DR. Methods: The fundus photographic set from each visit was analyzed by a single retinal expert; 793 of the 16 670 sets were classified as containing more than minimal DR (threshold for referral). The outcomes of the 2 algorithmic detectors were applied separately to the dataset and were compared by standard statistical measures. Main Outcome Measures: The area under the receiver operating characteristic curve (AUC), a measure of the sensitivity and specificity of DR detection. Results: Agreement was high, and examination results indicating more than minimal DR were detected with an AUC of 0.839 by the EyeCheck algorithm and an AUC of 0.821 for the Challenge2009 algorithm, a statistically nonsignificant difference (z-score, 1.91). If either of the algorithms detected DR in combination, the AUC for detection was 0.86, the same as the theoretically expected maximum. At 90% sensitivity, the specificity of the EyeCheck algorithm was 47.7% and that of the Challenge2009 algorithm was 43.6%. Conclusions: Diabetic retinopathy detection algorithms seem to be maturing, and further improvements in detection performance cannot be differentiated from best clinical practices, because the performance of competitive algorithm development now has reached the human intrareader variability limit. Additional validation studies on larger, well-defined, but more diverse populations of patients with diabetes are needed urgently, anticipating cost-effective early detection of DR in millions of people with diabetes to triage those patients who need further care at a time when they have early rather than advanced DR.
引用
收藏
页码:1147 / 1154
页数:8
相关论文
共 48 条
  • [1] Web-based screening for diabetic retinopathy in a primary care population: The EyeCheck project
    Abramoff, MD
    Suttorp-Schulten, MSA
    [J]. TELEMEDICINE JOURNAL AND E-HEALTH, 2005, 11 (06): : 668 - 674
  • [2] Abramoff MD, 2006, 28 ANN INT C IEEE EN, P4432, DOI DOI 10.1109/IEMBS.2006.259622
  • [3] Evaluation of a System for Automatic Detection of Diabetic Retinopathy From Color Fundus Photographs in a Large Population of Patients With Diabetes
    Abramoff, Michael D.
    Niemeijer, Meindert
    Suttorp-Schulten, Maria S. A.
    Viergever, Max A.
    Russell, Stephen R.
    van Ginneken, Bram
    [J]. DIABETES CARE, 2008, 31 (02) : 193 - 198
  • [4] [Anonymous], 1991, Ophthalmology, V98, P823
  • [5] [Anonymous], 1991, Ophthalmology, V98, P786
  • [6] [Anonymous], 2008, ENGLISH LANGUAGE LEA, P8
  • [7] A screening approach to the surveillance of patients with diabetes for the presence of vision-threatening retinopathy
    Bresnick, GH
    Mukamel, DB
    Dickinson, JC
    Cole, DR
    [J]. OPHTHALMOLOGY, 2000, 107 (01) : 19 - 24
  • [8] Chew EY, 2006, CURR OPIN OPHTHALMOL, V17, P519, DOI 10.1097/ICU.0b013e328010948d
  • [9] Economic and demographic trends signal an impending physician shortage
    Cooper, RA
    Getzen, TE
    McKee, HJ
    Laud, P
    [J]. HEALTH AFFAIRS, 2002, 21 (01) : 140 - 154
  • [10] A fully automated comparative microaneurysm digital detection system
    Cree, MJ
    Olson, JA
    McHardy, KC
    Sharp, PF
    Forrester, JV
    [J]. EYE, 1997, 11 (5) : 622 - 628