Comparative investigation of diagnostic media for induction motors: A case of rotor cage faults

被引:87
作者
Trzynadlowski, AM [1 ]
Ritchie, E
机构
[1] Univ Nevada, Dept Elect Engn, Reno, NV 89557 USA
[2] Univ Aalborg, Inst Energy Technol, DK-9220 Aalborg, Denmark
关键词
diagnostic media; fault diagnosis; induction motors; rotor faults;
D O I
10.1109/41.873218
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Results of a comparative experimental investigation of various media for noninvasive diagnosis of rotor faults in induction motors are presented. Stator voltages and currents in an induction motor were measured, recorded, and employed for computation of the partial and total input powers and of the estimated torque. Waveforms of the current, partial powers p(AB) and PCB, total power, and estimated torque were subsequently analyzed using the Fast Fourier Transform, Several rotor cage faults of increasing severity were studied with various load levels. The partial input power p(CB) was observed to exhibit the highest sensitivity to rotor faults. This medium is also the most reliable, as it includes a multiplicity of fault-induced spectral components.
引用
收藏
页码:1092 / 1099
页数:8
相关论文
共 10 条
[1]   ON THE APPLICATION AND DESIGN OF ARTIFICIAL NEURAL NETWORKS FOR MOTOR FAULT-DETECTION .1. [J].
CHOW, MY ;
SHARPE, RN ;
HUNG, JC .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1993, 40 (02) :181-188
[2]   MONITORING OF DEFECTS IN INDUCTION-MOTORS THROUGH AIR-GAP TORQUE OBSERVATION [J].
HSU, JS .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1995, 31 (05) :1016-1021
[3]   METHODS OF MOTOR CURRENT SIGNATURE ANALYSIS [J].
KLIMAN, GB ;
STEIN, J .
ELECTRIC MACHINES AND POWER SYSTEMS, 1992, 20 (05) :463-474
[4]   Instantaneous power as a medium for the signature analysis of induction motors [J].
Legowski, SF ;
Ula, AHMS ;
Trzynadlowski, AM .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1996, 32 (04) :904-909
[5]  
LI B, 1997, P IEEE IECON 97 NEW, P1113
[6]   PROTECTION OF SQUIRREL-CAGE INDUCTION-MOTOR UTILIZING INSTANTANEOUS POWER AND PHASE INFORMATION [J].
MAIER, R .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1992, 28 (02) :376-380
[7]   An unsupervised, on-line system for induction motor fault detection using stator current monitoring [J].
Schoen, RR ;
Lin, BK ;
Habetler, TG ;
Schlag, JH ;
Farag, S .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1995, 31 (06) :1280-1286
[8]   Diagnostics of mechanical abnormalities in induction motors using instantaneous electric power [J].
Trzynadlowski, AM ;
Ghassemzadeh, M ;
Legowski, SF .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1999, 14 (04) :1417-1422
[9]  
TRZYNADLOWSKI M, 1999, International Journal of Rotating Machinery, V5, P41, DOI [10.1155/S1023621X99000044, DOI 10.1155/S1023621X99000044]
[10]  
Vas P., 1993, PARAMETER ESTIMATION