Evaluation of an atmospheric pressure chemical ionization interface for capillary electrophoresis-mass spectrometry

被引:41
作者
Tanaka, Y
Otsuka, K
Terabe, S
机构
[1] Nippon Boehringer Ingelheim Co Ltd, Dept Analyt Chem, Kawanishi, Hyogo 6660193, Japan
[2] Himeji Inst Technol, Grad Sch, Kamigori, Hyogo 6781297, Japan
[3] Himeji Inst Technol, Fac Sci, Kamigori, Hyogo 6781297, Japan
关键词
capillary electrophoresis-mass spectrometry; modified interface; atmospheric pressure chemical ionization;
D O I
10.1016/S0731-7085(02)00532-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and inexpensive approach to modify a commercial atmospheric pressure chemical ionization (APCI) interface was proposed for capillary electrophoresis-mass spectrometry (CE-MS). In order to accommodate lower flow rates in the range 1-10 mul/min, both sheath liquid and nebulizing gas were coaxially supplied to the nebulizer as an arrangement of pneumatically assisted electrospray interface. Since this paper focused on the primary study of the modified APCI interface, the performance of the interface was first evaluated by the direct infusion of a reserpine solution. Optimization of several APCI parameters, such as temperature of APCI vaporizer, nebulizing gas flow and APCI corona discharge current, were accomplished. The orifice dimension for the nebulizing gas flow was largely independent of the MS sensitivity when the nebulizing gas flow rate was ca. 0.4 l/min. A successful CE-APCI-MS separation is obtained using the modified APCI interface. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1889 / 1895
页数:7
相关论文
共 12 条
[1]   CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY [J].
CAI, JY ;
HENION, J .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :667-692
[2]  
Isoo K, 2001, ELECTROPHORESIS, V22, P3426, DOI 10.1002/1522-2683(200109)22:16<3426::AID-ELPS3426>3.0.CO
[3]  
2-I
[4]   Advances in instrumentation in liquid chromatography mass spectrometry and related liquid-introduction techniques [J].
Niessen, WMA .
JOURNAL OF CHROMATOGRAPHY A, 1998, 794 (1-2) :407-435
[5]   State-of-the-art in liquid chromatography-mass spectrometry [J].
Niessen, WMA .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :179-197
[6]   High-temperature open tubular liquid chromatography coupled to atmospheric pressure chemical ionisation mass spectrometry [J].
Nyholm, LM ;
Sjoberg, PJR ;
Markides, KE .
JOURNAL OF CHROMATOGRAPHY A, 1996, 755 (02) :153-164
[7]  
Ozaki H, 1997, BUNSEKI KAGAKU, V46, P421
[8]   ONLINE COMBINATION OF MICELLAR ELECTROKINETIC CHROMATOGRAPHY AND MASS-SPECTROMETRY USING AN ELECTROSPRAY CHEMICAL-IONIZATION INTERFACE [J].
TAKADA, Y ;
SAKAIRI, M ;
KOIZUMI, H .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (06) :488-490
[9]   Strategy for selecting separation solutions in capillary electrophoresis mass spectrometry [J].
Tanaka, Y ;
Kishimoto, Y ;
Otsuka, K ;
Terabe, S .
JOURNAL OF CHROMATOGRAPHY A, 1998, 817 (1-2) :49-57
[10]   INFLUENCE OF CAPILLARY DIMENSIONS ON THE PERFORMANCE OF A COAXIAL CAPILLARY ELECTROPHORESIS ELECTROSPRAY MASS-SPECTROMETRY INTERFACE [J].
TETLER, LW ;
COOPER, PA ;
POWELL, B .
JOURNAL OF CHROMATOGRAPHY A, 1995, 700 (1-2) :21-26