Quantitative high-throughput determination of endogenous retinoids in human plasma using triple-stage liquid chromatography/tandem mass spectrometry

被引:63
作者
Gundersen, Thomas E.
Bastani, Nasser E.
Blomhoff, Rune
机构
[1] Univ Oslo, Inst Basic Med Sci, Oslo, Norway
[2] Vitas As, Oslo Innovat Pk, N-0349 Oslo, Norway
关键词
D O I
10.1002/rcm.2946
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-throughput ultrasensitive analytical method based on liquid chromatography with positive ion atmospheric pressure chemical ionization (APCI) coupled to tandem mass spectrometric detection (LC/MS/MS) was developed for the determination of all-trans-4-oxo-retinoic acid (at4oxoRA), 13-cis-4-oxo-retinoic acid (13c4oxoRA), 13-cis-retinoic acid (13cRA), all-trans-retinoic acid (atRA) and all-trans-retinol (atROH) in human plasma. A stable isotope of atRA was used as internal standard (IS). The analytes and IS were isolated from 100 ULL plasma by acetonitrile mono-phase extraction (MPE) performed in black 96-well microtiterplates. A 100 mu L injection was focused on-column and chromatographed on an Agilent ZORBAX SB-C18 rapid-resolution high-throughput (RRHT) column with 1.8-mu m particles (4.6 mm X 50 mm) maintained at 60 degrees C. The initial mobile phase composition was acetonitrile/water/formic acid (10:90:0.1, v/v/v) delivered at 1.8 mL/ min. Elution was accomplished by a fast gradient to acetonitrile/methanol/formic acid (90:10:0.1, v/v/ v). The method had a chromatographic total run time of 7 min. An Applied Biosystems 4000 Q TRAP linear tandem mass spectrometer equipped with a heated nebulizer (APCI) ionization source was operated in multiple reaction monitoring (MRM) mode with the precursor-to-product ion transitions m/z 315.4 -> 297 (4-oxo-retinoic acids), 301.2 -> 205 (retinoic acids), 305.0 -> 209 (IS) and 269.2 -> 93 (retinol) used for quantification. The assay was fully validated and found to have acceptable accuracy, precision, linearity, sensitivity and selectivity. The mean extraction recoveries from spiked plasma samples were 80-105% for the various retinoids at three different levels. The intra-day accuracy of the assay was within 8% of nominal and intra-day precision was better than 8% coefficient of variance (CV) for retinoic acids. Inter-day precision results for quality control samples run over a 12-day period alongside clinical samples showed mean precision better than 12.5% CV. The limit of quantification was in the range of 0.1-0.2 ng/mL and the mass limit of detection (mLOD) was in the range 1-4 pg on column for the retinoic acids. The assay has been successfully applied to the analysis of 1700 plasma samples. Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:1176 / 1186
页数:11
相关论文
共 34 条
[1]   NORMAL-PHASE LC-MS DETERMINATION OF RETINOIC ACID DEGRADATION PRODUCTS [J].
BEMPONG, DK ;
HONIGBERG, IL ;
MELTZER, NM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 13 (03) :285-291
[2]  
Blomhoff R., 1994, VITAMIN A HLTH DIS, DOI DOI 10.1201/9781482277562
[3]   HPLC-MS/MS analysis of the products generated from all-trans-retinoic acid using recombinant human CYP26A [J].
Chithalen, JV ;
Luu, L ;
Petkovich, M ;
Jones, G .
JOURNAL OF LIPID RESEARCH, 2002, 43 (07) :1133-1142
[4]   CHARACTERIZATION OF OXIDIZED AND GLUCURONIDATED METABOLITES OF RETINOL IN MONKEY PLASMA BY THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
ECKHOFF, C ;
WITTFOHT, W ;
NAU, H ;
SLIKKER, W .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1990, 19 (07) :428-433
[5]   QUANTIFICATION OF ACITRETIN IN HUMAN PLASMA BY MICROBORE LIQUID-CHROMATOGRAPHY NEGATIVE CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
FAYER, BE ;
HUSELTON, CA ;
GARLAND, WA ;
LIBERATO, DJ .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 568 (01) :135-144
[6]   Quantitative high-performance liquid chromatographic determination of retinoids in human serum using on-line solid-phase extraction and column switching - Determination of 9-cis-retinoic acid, 13-cis-retinoic acid, all-trans-retinoic acid, 4-oxo-all-trans-retinoic acid and 4-oxo-13-cis-retinoic acid [J].
Gundersen, TE ;
Lundanes, E ;
Blomhoff, R .
JOURNAL OF CHROMATOGRAPHY B, 1997, 691 (01) :43-58
[7]  
Gundersen TE, 1999, METHOD ENZYMOL, V299, P430
[8]   Methods for detecting and identifying retinoids in tissue [J].
Gundersen, Thomas E. .
JOURNAL OF NEUROBIOLOGY, 2006, 66 (07) :631-644
[9]  
Hoover F, 2001, J COMP NEUROL, V436, P324
[10]   Quantification of endogenous retinoic acid in limited biological samples by LC/MS/MS [J].
Kane, MA ;
Chen, N ;
Sparks, S ;
Napoli, JL .
BIOCHEMICAL JOURNAL, 2005, 388 :363-369