Amperometric determination of bonded glucose with an MnO2 and glucose oxidase bulk-modified screen-printed electrode using flow-injection analysis

被引:54
作者
Turkusic, E
Kalcher, J
Kahrovic, E
Beyene, NW
Moderegger, H
Sofic, E
Begic, S
Kalcher, K
机构
[1] Univ Sarajevo, Fac Sci, Dept Chem, Sarajevo 71000, Bosnia & Herceg
[2] Graz Univ, Inst Chem Theoret Chem, A-8010 Graz, Austria
[3] Graz Univ, Inst Chem Analyt Chem, A-8010 Graz, Austria
关键词
bonded glucose; screen-printed electrode; manganese dioxide; glucose oxidase; glucosidase; flow-injection analyses;
D O I
10.1016/j.talanta.2004.07.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A screen-printed amperometric biosensor based on carbon ink double bulk-modified with MnO2 as a mediator and glucose oxidase as a biocomponent was investigated for its ability to serve as a detector for bonded glucose in different compounds, such as cellobiose, saccharose, (-)-4-nitrophenyl-beta-glucopyranoside, as well as in beer samples by flow-injection analysis (FIA). The biosensor could be operated under physiological conditions (0.1 M phosphate buffer, pH 7.5) and exhibited good reproducibility and stability. Bonded glucose was released with glucosidase in Solution. and the free glucose was detected with the modified screen-printed electrode (SPE). The release of glucose by the aid of glucosidase from cellobiose. saccharose and (-)-4-nitrophenyl-beta-D-glucopyranoside in solution showed that stoichiometric quantities of free glucose could be monitored in all three cases. The linear range of the amperometric response of the biosensor in the FIA-mode flow rate 0.2 mL min(-1), injection volume 0.25 mL, operation potential 0.48 V versus Ag/AgCl extends from 11 to 13,900 mu-mol L-1 glucose in free form. The limit of detection (3sigma) is 1 mumol L-1 glucose. A concentration of 100 mumol L-1 yields a relative standard deviation of approximately 7% with five injections. These values correspond to the same concentrations of bonded glucose Supposed that it is liberated quantitatively (incubation for 2 h with glucosidase). Bonded glucose could be determined in beer samples using the same assay. The results corresponded very well with the reference procedure. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:559 / 564
页数:6
相关论文
共 20 条
  • [1] [Anonymous], KLINISCHES LABOR
  • [2] Integration of bienzymatic disaccharide sensors for simultaneous determination of disaccharides by means of light addressable potentiometric sensor
    Aoki, K
    Uchida, H
    Katsube, T
    Ishimaru, Y
    Iida, T
    [J]. ANALYTICA CHIMICA ACTA, 2002, 471 (01) : 3 - 12
  • [3] BAKKEREN DL, 1999, CLIN LAB, V45, P123
  • [4] BEUTLER HO, 1994, METH CARBOHYDRATE CH, V10, P45
  • [5] Determination of β-glucan content of cereals with an amperometric glucose electrode
    Boyaci, IH
    Seker, UÖS
    Mutlu, M
    [J]. EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2002, 215 (06) : 538 - 541
  • [6] SELECTIVE ADSORPTION OF IMMUNOGLOBULINS AND GLUCOSYLATED PROTEINS ON PHENYLBORONATE AGAROSE
    BRENA, BM
    BATISTAVIERA, F
    RYDEN, L
    PORATH, J
    [J]. JOURNAL OF CHROMATOGRAPHY, 1992, 604 (01): : 109 - 115
  • [7] Carta M, 1997, EUR J CLIN CHEM CLIN, V35, P923
  • [8] FISCHER RW, 1980, CLIN LAB HAEMATOL, V2, P129
  • [9] GREWAL J, 1991, MICROCHEM J, P44
  • [10] Groche D, 2003, Clin Lab, V49, P657