Hemodynamic performance of the 21-mm St. Jude Bioimplant prosthesis using Dobutamine Doppler echocardiography

被引:6
作者
Kadir, I
Izzat, MB
Birdi, I
Wilde, P
Reeves, B
Walsh, C
Bryan, A
Angelini, G
机构
[1] Univ Bristol, Bristol Heart Inst, Dept Clin Radiol, Bristol, Avon, England
[2] Univ Bristol, Res & Dev Support Unit, Bristol, Avon, England
关键词
D O I
10.1016/S0002-9149(97)00968-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study examines the hemodynamic performance of small size St. Jude Biolmplant aortic prostheses using dobutamine echocardiography, Eleven patients (3 women, mean age 75 years) who had undergone aortic valve replacement with a size 21-mm St. Jude Biolmplant aortic prostheses at 10.8 +/- 5.1 months (SD) previously were studied. Dobutamine infusion was started at a rate of 5 mu g/kg/min and increased to 10 mu g/kg/min, and subsequently to 20 mu g/kg/min at 15-minute intervals, Pulsed and continuous-wave Doppler studies were performed at rest and at the end of each stage, Effective orifice area, mean gradient, and the performance index across each prosthesis were calculated and cardiac output was determined by Doppler measurement of flow in the left ventricular outflow tract. Stress dobutamine increased heart rate and cardiac output by 51% and 56%, respectively (both p < 0.0001), and the mean transvalvular gradient increased from 30.1 +/- 7.5 mm Hg at rest to 49.3 +/- 11.5 mm Hg at maximum stress (p < 0.0005). The performance index increased progressively from 0.29 +/- 0.05 at rest to 0.40 +/- 0.10 at maximum stress (p < 0.0005). Regression modeling analyses demonstrated that the maximum stress gradient was independent of all variables except the resting gradient (p = 0.03), Body surface area had no effect on the changes in cardiac output, effective orifice area, or transprosthetic gradient at maximum stress. Thus, these data demonstrate that the size 21-mm St. Jude Biolmplant prosthesis exhibits suboptimal hemodynamic performance with transvalvular gradients consistent with mild to moderate aortic stenosis, both at rest and under stress conditions. (C) 1998 by Excerpta Medica, Inc.
引用
收藏
页码:599 / 603
页数:5
相关论文
共 27 条
[1]  
Arom K V, 1994, J Heart Valve Dis, V3, P531
[2]   JUDE,ST MEDICAL PROSTHESIS - ANOTHER 10-YEAR FOLLOW-UP REPORT [J].
AROM, KV .
ANNALS OF THORACIC SURGERY, 1993, 56 (03) :403-404
[3]   CLINICAL-EXPERIENCE WITH THE ZERO-PRESSURE-FIXED MEDTRONIC INTACT BIOPROSTHETIC VALVE [J].
BARRATTBOYES, BG .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1992, 6 :S79-S81
[4]   DISCREPANCIES BETWEEN DOPPLER AND CATHETER GRADIENTS IN AORTIC PROSTHETIC VALVES INVITRO - A MANIFESTATION OF LOCALIZED GRADIENTS AND PRESSURE RECOVERY [J].
BAUMGARTNER, H ;
KHAN, S ;
DEROBERTIS, M ;
CZER, L ;
MAURER, G .
CIRCULATION, 1990, 82 (04) :1467-1475
[5]   CLINICAL AND HEMODYNAMIC PERFORMANCE OF THE 19-MM CARPENTIER-EDWARDS PORCINE BIOPROSTHESIS [J].
BOJAR, RM ;
RASTEGAR, H ;
PAYNE, DD ;
MACK, CA ;
SCHWARTZ, SL .
ANNALS OF THORACIC SURGERY, 1993, 56 (05) :1141-1147
[6]   CONTINUOUS WAVE DOPPLER ECHOCARDIOGRAPHIC MEASUREMENT OF PROSTHETIC VALVE GRADIENTS - A SIMULTANEOUS DOPPLER-CATHETER CORRELATIVE STUDY [J].
BURSTOW, DJ ;
NISHIMURA, RA ;
BAILEY, KR ;
REEDER, GS ;
HOLMES, DR ;
SEWARD, JB ;
TAJIK, AJ .
CIRCULATION, 1989, 80 (03) :504-514
[7]   AORTIC-VALVE REPLACEMENT WITH HANCOCK PORCINE XENOGRAFT [J].
COHN, LH ;
SANDERS, JH ;
COLLINS, JJ .
ANNALS OF THORACIC SURGERY, 1976, 22 (03) :221-227
[8]  
COSGROVE DM, 1985, J THORAC CARDIOV SUR, V89, P358
[9]  
Craver J M, 1979, Circulation, V60, P93
[10]  
DEPAULIS R, 1994, J THORAC CARDIOV SUR, V108, P57