Clinical and ultrasonic long-term results of percutaneous transluminal carotid angioplasty - A prospective follow-up of 30 carotid angioplasties

被引:11
作者
Schoser, BGH
Becker, VU
Eckert, B
Zeumer, H
Thie, A
机构
[1] Univ Hamburg, Hosp Eppendorf, Dept Neurol, D-20246 Hamburg, Germany
[2] Univ Hamburg, Hosp Eppendorf, Dept Neuroradiol, D-20246 Hamburg, Germany
[3] Itzehoe Hosp, Dept Neurol, Itzehoe, Germany
关键词
carotid artery disease; angioplasty; ultrasound; follow-up;
D O I
10.1159/000015813
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Experience of the long-term outcome of patients treated with carotid balloon angioplasty is limited. Therefore, we prospectively analyzed the ultrasonic and clinical features of 29 patients with complete follow-up data beyond 24 months, evaluated from 1989 through 1996 from our carotid angioplasty cohort of 106 patients. Mean follow-up time was 33 months. For up to 78 months postangioplasty, 23 patients with 34 angioplasties (77%) had no further neurological sequelae. Single ipsilateral amaurosis fugax or TIA events occurred in 3 patients. Recurrent ipsilateral amaurosis fugax or TIA events were noted twice in 2 patients, No patient suffered an ipsilateral stroke. Fifteen angioplasties (50%) remained with normal ultrasound (stenosis <50%), mild restenosis (50-70%) occurred in 12 angioplasties (40%), and severe restenosis (>70%) in 3 angioplasties (10%). Only in 2 of 15 patients clinical complications were related to the occurrence of ipsilateral restenosis above 50%, Until now, rigorous and careful evaluation of patients and clinical and ultrasonic follow-up have been essential for the estimation of the long-term efficacy of carotid angioplasty. It should be noted that carotid angioplasty is a new technique in evolution, with a high potential improving the technical results.
引用
收藏
页码:38 / 41
页数:4
相关论文
共 31 条
[1]  
Ammar AD, 1996, STROKE, V27, P2143
[2]   Concern about safety of carotid angioplasty [J].
Beebe, HG ;
Archie, JP ;
Baker, WH ;
Barnes, RW ;
Becker, GJ ;
Bernstein, EF ;
Brener, B ;
Clagett, GP ;
Clowes, AW ;
Cooke, JP ;
Creager, MA ;
Cronenwett, JL ;
Dake, M ;
DeWeese, JA ;
Fogarty, TJ ;
Freischlag, JA ;
Goldstone, J ;
Greenfield, LJ ;
Hertzer, NR ;
Hobson, RW ;
Joyce, JW ;
Katzen, BT ;
LoGerfo, FW ;
Mohr, JP ;
Moore, WS ;
Najafi, H ;
Ricotta, JJ ;
Riles, TS ;
Ring, EJ ;
Robertson, J ;
Rutherford, RB ;
Sos, T ;
Stanley, JC ;
Strandness, DE ;
Sumner, DS ;
Toole, J ;
Towne, JB ;
Veith, FJ ;
Whittemore, AD ;
Yao, JST ;
Zarins, CK .
STROKE, 1996, 27 (02) :197-198
[3]   PERCUTANEOUS TRANS-LUMINAL ANGIOPLASTY OF FIBROMUSCULAR DYSPLASIA OF THE INTERNAL CAROTID-ARTERY [J].
BELAN, A ;
VESELA, M ;
VANEK, I ;
WEISS, K ;
PEREGRIN, JH .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1982, 5 (02) :79-81
[4]  
BOCKENHEIMER SAM, 1983, AM J NEURORADIOL, V4, P791
[5]   IS ROUTINE DUPLEX EXAMINATION AFTER CAROTID ENDARTERECTOMY JUSTIFIED [J].
COOK, JM ;
THOMPSON, BW ;
BARNES, RW .
JOURNAL OF VASCULAR SURGERY, 1990, 12 (03) :334-340
[6]  
COURTHEOUX P, 1987, NEURORADIOLOGY, V29, P186
[7]   Delayed improvement in carotid artery diameter after carotid angioplasty [J].
Crawley, F ;
Clifton, A ;
Markus, H ;
Brown, MM .
STROKE, 1997, 28 (03) :574-579
[8]   QUANTIFICATION OF ATHEROMATOUS STENOSIS IN THE EXTRACRANIAL INTERNAL CAROTID-ARTERY [J].
DEBRAY, JM ;
GLATT, B .
CEREBROVASCULAR DISEASES, 1995, 5 (06) :414-426
[9]  
DUUBLIN AB, 1994, AM J NEURORADIOL, V5, P646
[10]   Angioplasty of the internal carotid artery: Results, complications and follow-up in 61 cases [J].
Eckert, B ;
Zanella, FE ;
Thie, A ;
Steinmetz, J ;
Zeumer, H .
CEREBROVASCULAR DISEASES, 1996, 6 (02) :97-105