Capillary-discharge-based portable detector for chemical vapor monitoring

被引:20
作者
Duan, YX [1 ]
Su, YX [1 ]
Jin, Z [1 ]
机构
[1] Los Alamos Natl Lab, Div Chem, Los Alamos, NM 87545 USA
关键词
D O I
10.1063/1.1569401
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Conventional portable instruments for sensing chemical vapors have certain limitations for on-site use. In this article, we develop a genuinely portable detector that is sensitive, powerful, rugged, of simple design, and with very low power needs. Such a detector is based on a dry-cell battery-powered, capillary-discharge-based, microplasma source with optical emission detection. The microscale plasma source has very special features such as low thermal temperature and very low power needs. These features make it possible for the plasma source to be powered with a small dry-cell battery. A specially designed discharge chamber with minielectrodes can be configured to enhance the plasma stability and the system performance. A very small amount of inert gas can be used as sample carrier and plasma supporting gas. Inert gases possess high excitation potentials and produce high-energy metastable particles in the plasma. These particles provide sufficient energy to excite chemical species through Penning ionization and/or energy transfer from metastable species. A molecular emission spectrum can be collected with a palm-sized spectrometer through a collimated optical fiber. The spectrum can be displayed on a notebook computer. With this design and arrangement, the new detector provides high sensitivity for organic chemical species. The advantages and features of the newly developed detector include high sensitivity, simple structure, low cost, universal response, very low power consumption, compact volume with field portable capability, and ease of operation.
引用
收藏
页码:2811 / 2816
页数:6
相关论文
共 31 条
[1]   DIRECT CURRENT DISCHARGE SPECTRAL EMISSION-TYPE DETECTOR [J].
BRAMAN, RS ;
DYNAKO, A .
ANALYTICAL CHEMISTRY, 1968, 40 (01) :95-&
[2]   CHARACTERIZATION OF AN ANNULAR HELIUM INDUCTIVELY COUPLED PLASMA GENERATED IN A LOW-GAS-FLOW TORCH [J].
CHAN, SK ;
MONTASER, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (04) :591-597
[3]  
Chen YH, 1997, B ELECTROCHEM, V13, P183
[4]  
Czanderna A.W., 1984, APPL PIEZOELECTRIC Q, V7, P1
[5]   Monitoring surface and airborne inorganic contamination in the workplace by a field portable X-ray fluorescence spectrometer [J].
Dost, AA .
ANNALS OF OCCUPATIONAL HYGIENE, 1996, 40 (05) :589-610
[6]  
Eckenrode BA, 1998, FIELD ANAL CHEM TECH, V2, P3, DOI 10.1002/(SICI)1520-6521(1998)2:1<3::AID-FACT2>3.0.CO
[7]  
2-Z
[8]  
EICEMAN GA, 1991, CRIT REV ANAL CHEM, V22, P17
[9]  
EICEMAN GA, 1994, ION MOBILITY SPECTRO, P146
[10]  
EICEMAN GA, 1994, ION MOBILITY SPECTRO