A 100-200 MHz ultrasound biomicroscope

被引:54
作者
Knapik, DA [1 ]
Starkoski, B
Pavlin, CJ
Foster, FS
机构
[1] Univ Toronto, Dept Med Biophys, Sunnybrook & Womens Coll, Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[2] Ontario Canc Inst, Ocular Oncol Serv, Toronto, ON M5G 2M9, Canada
基金
英国医学研究理事会;
关键词
D O I
10.1109/58.883543
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The development of higher frequency ultrasound imaging systems affords a unique opportunity to visualize living tissue at the microscopic level. This work was undertaken to assess the potential of ultrasound imaging in vivo using the 100-200 MHz range. Spherically focused lithium niobate transducers were fabricated. The properties of a 200 MHz center frequency device are described in detail. This transducer showed good sensitivity with an insertion loss of 18 dB at 200 MHz;. Resolution of 14 mum in the lateral direction and 12 mum in the axial direction was achieved with f/1.14 focusing. A linear mechanical scan system and a scan converter were used to generate B-scan images at a frame rate up to 12 frames per second. System performance in B-mode imaging is limited by frequency dependent attenuation in tissues. An alternative technique, zone-focus image collection, was investigated to extend depth of field. Images of coronary arteries, the eye, and skin are presented along with some preliminary correlations with histology. These results demonstrate the feasibility of ultrasound biomicroscopy in the 100-200 MHz range. Further development of ultrasound backscatter imaging at frequencies up to and above 200 MHz will contribute valuable information about tissue microstructure.
引用
收藏
页码:1540 / 1549
页数:10
相关论文
共 34 条
[1]  
[Anonymous], 1995, ULTRASOUND BIOMICROS
[2]  
BOM N, 1997, SEMIN INTERVENT CARD, V2, P1
[3]  
COHEN NA, 1997, IEEE T ULTRASON FERR, V44, P1304
[4]  
DAFT CMW, 1989, J ACOUST SOC AM, V85, P2195
[5]  
Foster F S, 1997, Semin Interv Cardiol, V2, P33
[6]   PRINCIPLES AND APPLICATIONS OF ULTRASOUND BACKSCATTER MICROSCOPY [J].
FOSTER, FS ;
PAVLIN, CJ ;
LOCKWOOD, GR ;
RYAN, LK ;
HARASIEWICZ, KA ;
BERUBE, L ;
RAUTH, AM .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (05) :608-617
[7]   CHARACTERIZATION OF LEAD ZIRCONATE TITANATE CERAMICS FOR USE IN MINIATURE HIGH-FREQUENCY (20-80 MHZ) TRANSDUCERS [J].
FOSTER, FS ;
RYAN, LK ;
TURNBULL, DH .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1991, 38 (05) :446-453
[8]   NEW EQUIVALENT CIRCUITS FOR ELEMENTARY PIEZOELECTRIC TRANSDUCERS [J].
KRIMHOLTZ, R ;
LEEDOM, DA ;
MATTHAEI, GL .
ELECTRONICS LETTERS, 1970, 6 (13) :398-+
[9]   THE DESIGN OF PROTECTION CIRCUITRY FOR HIGH-FREQUENCY ULTRASOUND IMAGING-SYSTEMS [J].
LOCKWOOD, GR ;
HUNT, JW ;
FOSTER, FS .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1991, 38 (01) :48-55
[10]   A 45 TO 55 MHZ NEEDLE-BASED ULTRASOUND SYSTEM FOR INVASIVE IMAGING [J].
LOCKWOOD, GR ;
RYAN, LK ;
FOSTER, FS .
ULTRASONIC IMAGING, 1993, 15 (01) :1-13