Diagnosis of Internal Derangement of the Knee at 3.0-T MR Imaging: 3D Isotropic Intermediate-weighted versus 2D Sequences

被引:92
作者
Jung, Jee Young [1 ]
Yoon, Young Cheol [1 ]
Kwon, Jong Won [1 ]
Ahn, Jin Hwan [2 ]
Choe, Bong-Keun [3 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Orthoped Surg, Seoul 135710, South Korea
[3] Kyung Hee Univ, Sch Med, Dept Prevent Med, Seoul, South Korea
关键词
ANTERIOR CRUCIATE LIGAMENT; FAST-SPIN-ECHO; 3-DIMENSIONAL GRADIENT-ECHO; ARTICULAR-CARTILAGE; MENISCAL TEARS; MULTIPLANAR RECONSTRUCTION; PROJECTION RECONSTRUCTION; MUSCULOSKELETAL MRI; ARTHROSCOPY; EFFICACY;
D O I
10.1148/radiol.2533090457
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: To compare three-dimensional (3D) isotropic fast spin-echo (SE) intermediate-weighted magnetic resonance (MR) imaging with two-dimensional (2D) fast SE MR imaging-both performed at 3.0 T-for performance in the diagnosis of internal derangements of the knee. Materials and Methods: The institutional review board approved this HIPAA-compliant study, and the requirement for informed consent was waived. The authors retrospectively reviewed 87 knee MR images obtained in 85 patients who had undergone both 3D isotropic and 2D MR examinations of the knee at 3.0 T and subsequent arthroscopic surgery. The 2D MR images included intermediate-weighted coronal and sagittal images, intermediate-weighted axial images with fat saturation, and T2-weighted sagittal images. The 3D isotropic MR images were obtained with multiplanar reformation (MPR), a fast SE intermediate-weighted sequence, and a reconstruction voxel size of 0.5 x 0.5 x 0.5 mm. Two radiologists retrospectively and independently evaluated the 2D and 3D data sets, at different sessions, for the presence of medial meniscus (MM), lateral meniscus (LM), anterior cruciate ligament (ACL), and posterior cruciate ligament (PCL) tears. These interpretations were compared with the arthroscopic surgery findings. The statistical differences between the sensitivities, specificities, and accuracies of the two methods were determined at McNemar testing, with surgical findings serving as the reference standard. Interobserver agreement was calculated by using kappa coefficients. Results: For both reviewers, the sensitivity, specificity, and accuracy of both MR techniques were higher than 95% for the diagnosis of ACL and PCL tears, higher than 85% for the diagnosis of MM tears, and higher than 80% for the diagnosis of LM tears. There were no significant differences in sensitivity, specificity, or accuracy between the two methods. Interobserver agreement for evaluation of all lesions was excellent and ranged from 0.81 (LM tears evaluated with 3D and 2D sequences) to 0.93 (ACL tears evaluated with 3D and 2D sequences, PCL tears evaluated with 2D sequence, and MM tears evaluated with 3D sequence). Conclusion: The performance of 3D isotropic fast SE intermediate-weighted MR imaging with MPR was not significantly different from that of 2D MR imaging in the diagnosis of cruciate ligament and meniscal tears of the knee. (C) RSNA, 2009
引用
收藏
页码:780 / 787
页数:8
相关论文
共 38 条
[1]
MR DIAGNOSIS OF INTERNAL DERANGEMENTS OF THE KNEE - EFFECT OF FIELD-STRENGTH ON EFFICACY [J].
BARNETT, MJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (01) :115-118
[2]
SIGNAL-TO-NOISE RATIO AND SECTION THICKNESS IN TWO-DIMENSIONAL VERSUS 3-DIMENSIONAL FOURIER-TRANSFORM MR IMAGING [J].
CARLSON, J ;
CROOKS, L ;
ORTENDAHL, D ;
KRAMER, DM ;
KAUFMAN, L .
RADIOLOGY, 1988, 166 (01) :266-270
[3]
Chen WT, 2002, ACTA RADIOL, V43, P511
[4]
MENISCAL TEARS OF THE KNEE - ACCURACY OF MR IMAGING [J].
CRUES, JV ;
MINK, J ;
LEVY, TL ;
LOTYSCH, M ;
STOLLER, DW .
RADIOLOGY, 1987, 164 (02) :445-448
[5]
Clinical, MRI, and arthroscopic findings associated with failure to diagnose a lateral meniscal tear on knee MRI [J].
De Smet, Arthur A. ;
Mukherjee, Rajat .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (01) :22-26
[6]
MR DIAGNOSIS OF MENISCAL TEARS OF THE KNEE - IMPORTANCE OF HIGH SIGNAL IN THE MENISCUS THAT EXTENDS TO THE SURFACE [J].
DESMET, AA ;
NORRIS, MA ;
YANDOW, DR ;
QUINTANA, FA ;
GRAF, BK ;
KEENE, JS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (01) :101-107
[7]
Internal knee derangement assessed with 3-minute three-dimensional isovoxel true FISP MR sequence: Preliminary study [J].
Duc, Sylvain R. ;
Pfirrmann, Christian W. A. ;
Koch, Peter P. ;
Zanetti, Marco ;
Hodler, Juerg .
RADIOLOGY, 2008, 246 (02) :526-535
[8]
Diagnosis of articular cartilage abnormalities of the knee: Prospective clinical evaluation of a 3D water-excitation true FISP sequence [J].
Duc, Sylvain R. ;
Koch, Peter ;
Schmid, Marius R. ;
Horger, Wilhelm ;
Hodler, Juerg ;
Pfirrmann, Christian W. A. .
RADIOLOGY, 2007, 243 (02) :475-482
[9]
ACCURACY OF DIAGNOSES FROM MAGNETIC-RESONANCE-IMAGING OF THE KNEE - A MULTICENTER ANALYSIS OF 1014 PATIENTS [J].
FISCHER, SP ;
FOX, JM ;
DELPIZZO, W ;
FRIEDMAN, MJ ;
SNYDER, SJ ;
FERKEL, RD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) :2-10
[10]
Fritz Russell C, 2003, Magn Reson Imaging Clin N Am, V11, P283