Evaluation and interference study of hemoglobin A1c measured by turbidimetric inhibition immunoassay

被引:36
作者
Chang, J
Hoke, C
Ettinger, B
Penerian, G
机构
[1] Kaiser Permanente Reg Lab, Dept Chem, Berkeley, CA 94710 USA
[2] Kaiser Permanente Med Care Program, Div Res, Oakland, CA 94611 USA
关键词
hemoglobin A(1c); turbidimetric immunoinhibition; high-performance liquid chromatography; affinity chromatography; diabetes mellitus; glycated hemoglobin;
D O I
10.1093/ajcp/109.3.274
中图分类号
R36 [病理学];
学科分类号
100104 [病理学与病理生理学];
摘要
The technical performance of the turbidimetric immunoinhibition (TI) assay for hemoglobin (Hb) Al-1c (Tina-quant Hb A(1c), Boehringer Mannheim, Indianapolis, Ind) was evaluated by using the BM/Hitachi 911 analyzer. Intra-assay imprecision was less than 2.7%, and interassay imprecision was less than 2.8% as measured by coefficient of variation. In 93 subjects with diabetes who did not have hemoglobin variants, results of the TI assay for Hb A(1c) correlated strongly with those obtained by using a highperformance liquid chromatography analyzer (Diamat, BioRad Laboratories, Hercules, Calif). Among 241 subjects who had or did not have hemoglobin variants, the TI assay for Hb A(1c) correlated strongly with results of affinity chromatography for total glycated hemoglobin (Glyc-Affin GHb, IsoLab, Akron, Ohio). We also studied the effect of various percentages of hemoglobin S, C, E, and F on the accuracy of the TI Hb A(1c) assay. Only high hemoglobin F percentages caused interference. More than 14 times as many samples can be analyzed per hour by using the TI Hb A(1c) assay than can be analyzed by using the HPLC assay. For high-volume reference laboratories, using the fully automated TI Hb A(1c) assay to monitor glycemic control in patients with diabetes may be preferable to using the conventional ion-exchange highperformance liquid chromatography Hb A(1c) assay because the TI assay measures Hb A(1c) more accurately in patients with diabetes who have hemoglobin variants, and it requires less time.
引用
收藏
页码:274 / 278
页数:5
相关论文
共 14 条
[1]
ALEYASSINE H, 1979, CLIN CHEM, V25, P1484
[2]
HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF HUMAN HEMOGLOBINS - SIMULTANEOUS QUANTITATION OF FETAL AND GLYCATED HEMOGLOBINS [J].
BISSE, E ;
WIELAND, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 434 (01) :95-110
[3]
CONCEPCION JM, 1994, J CLIN IMMUNOASSAY, V17, P139
[4]
GOLDSTEIN DE, 1986, CLIN CHEM, V32, pB64
[5]
TESTS OF GLYCEMIA IN DIABETES [J].
GOLDSTEIN, DE ;
LITTLE, RR ;
LORENZ, RA ;
MALONE, JI ;
NATHAN, D ;
PETERSON, CM .
DIABETES CARE, 1995, 18 (06) :896-909
[6]
Goldstein DE, 1986, METHODS DIABETES RES, V2, P475
[7]
QUANTITATIVE MEASUREMENT OF HBA(1C) BY AN IMMUNOTURBIDIMETRIC ASSAY COMPARED TO A STANDARD HPLC METHOD [J].
HAMWI, A ;
SCHWEIGER, CR ;
VEITL, M ;
SCHMID, R .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1995, 104 (01) :89-95
[8]
JARAUSCH J, 1993, KLIN LABOR, V39, P997
[9]
JEPPSSON JO, 1986, CLIN CHEM, V32, P1867
[10]
JOHN WG, 1993, CLIN CHEM, V39, P663