An X-ray charge-density feasibility study at 56 keV of magnesium formate dihydrate using a CCD area detector

被引:19
作者
Graafsma, H [1 ]
Svensson, SO [1 ]
Kvick, A [1 ]
机构
[1] European Synchrotron Radiat Facil, F-38043 Grenoble, France
关键词
D O I
10.1107/S0021889897004135
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A high-resolution structural study of magnesium formate dihydrate was performed using high-energy synchrotron radiation (0.22 Angstrom) and an X-ray image intensifier/CCD (charge-coupled device) detector. The complete data collection was performed in less than 2 h. The data were treated by two different integration programs and the results are compared. The data quality was sufficiently high to produce good-quality electron difference density maps.
引用
收藏
页码:957 / 962
页数:6
相关论文
共 13 条
[1]  
Blessing R. H., 1989, Journal of Applied Crystallography, V22, P396, DOI 10.1107/S0021889889001639
[2]   THE SEED-SKEWNESS METHOD FOR INTEGRATION OF PEAKS ON IMAGING PLATES [J].
BOLOTOVSKY, R ;
WHITE, MA ;
DAROVSKY, A ;
COPPENS, P .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1995, 28 (pt 2) :86-95
[3]   THE USE OF IMAGING PLATES IN ELECTRON-DENSITY MAPPING WITH SYNCHROTRON X-RAYS [J].
BOLOTOVSKY, R ;
DAROVSKY, A ;
KEZERASHVILI, V ;
COPPENS, P .
JOURNAL OF SYNCHROTRON RADIATION, 1995, 2 :181-184
[4]  
BRUNNING H, 1992, THESIS TWENTE U NETH
[5]  
Coppens P., 1992, SYNCHROTRON RAD CRYS
[6]  
DEWITH G, 1976, ACTA CRYSTALLOGR B, V32, P1980
[7]  
Hammersley A. P., 1995, EXPAH9501 ESRF
[8]  
HAMMERSLEY AP, 1995, REV SCI INSTRUM, V66, P2727
[9]   THE MATERIALS SCIENCE AND LAUE DIFFRACTION BEAMLINES AT THE EUROPEAN SYNCHROTRON RADIATION FACILITY [J].
KVICK, A ;
WULFF, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :1073-1076
[10]   A novel technique for accurate intensity calibration of area X-ray detectors at almost arbitrary energy [J].
Moy, JP ;
Hammersley, AP ;
Svensson, SO ;
Thompson, A ;
Brown, K ;
Claustre, L ;
Gonzalez, A ;
McSweeney, S .
JOURNAL OF SYNCHROTRON RADIATION, 1996, 3 :1-5