The clinical usefulness of the fingers-to-palm ratio in different hand microcirculatory abnormalities

被引:15
作者
Galuska, L [1 ]
Garai, I [1 ]
Csiki, Z [1 ]
Varga, J [1 ]
Bodolay, E [1 ]
Bajnok, L [1 ]
机构
[1] Univ Med Sch Debrecen, Nucl Med Ctr, H-4012 Debrecen, Hungary
关键词
D O I
10.1097/00006231-200007000-00010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A non-invasive nuclear medicine technique was developed to screen patients with painful hands so as to separate patients with a normal from those with an abnormal microcirculation of the hands in different clinical conditions. Such a technique is important, as the other methods available are either subjective or rather complicated. The study population consisted of 10 healthy individuals, 23 patients with Raynaud's syndrome and 15 patients with mixed connective tissue disease (MCTD). Sixty gamma-camera images of the hands (1 s each) were recorded after a bolus injection of Tc-99(m)-DTPA via a dorsal foot vein. Regions of interest were drawn on the summed images around the fingers and the palmar region. The fingers-to-palm ratio was then calculated from the total counts inside these regions of interest separately for each hand. The mean fingers-to-palm ratio was 0.94 +/- 0.18 (0.71-1.25) for the healthy group, 0.57 +/- 0.22 (0.21 +/- 1.11) for the MCTD group and 0.40+/-0.14 (0.18-0.77) for the Raynaud's patients. Analysis of variance showed these differences to be highly significant (P<0.001). There were also significant differences between 6 MCTD patients in an active (mean 0.48) and nine patients in an inactive (mean 0.66) clinical state (two-sample t-test: P < 0.05). There were no significant differences between the fingers-to-palm ratios of the left and right hands of the same patients tone-sample t-test). Of the 23 primary Raynaud's patients, capillary microscopic data were pathological in only eight (34%). We conclude that our method is able to differentiate between patients with normal and those with abnormal microcirculation of the hands. Although measurement of the fingers-to-palm ratio is not a specific method, it is useful both for staging and in the follow-up of patients. ((C) 2000 Lippincott Williams & Wilkins).
引用
收藏
页码:659 / 663
页数:5
相关论文
共 13 条
[1]  
ALNAHHAS AM, 1994, EUR J NUCL MED, V21, P258
[2]  
Bang Shin Ho, 1992, Korean Journal of Internal Medicine (English Edition), V7, P94
[3]   The poor man's capillary microscope. A novel technique for the assessment of capillary morphology [J].
Bauersachs, RM ;
Lossner, F .
ANNALS OF THE RHEUMATIC DISEASES, 1997, 56 (07) :435-437
[4]   Advances in microcirculation network evaluation: An update [J].
Fagrell, B .
INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1995, 15 :34-40
[5]   Scintigraphic assessment of distal extremity perfusion in 17 patients [J].
Goggin, JM ;
Hoskinson, JJ ;
Carpenter, JW ;
Roush, JK ;
McLaughlin, RM ;
Anderson, DE .
VETERINARY RADIOLOGY & ULTRASOUND, 1997, 38 (03) :211-220
[6]  
Greenstein D, 1994, Cardiovasc Surg, V2, P354
[7]   LASER-DOPPLER PERFUSION IMAGING OF MICROVASCULAR BLOOD-FLOW IN RABBIT TENUISSIMUS MUSCLE [J].
LINDEN, M ;
SIRSJO, A ;
LINDBOM, L ;
NILSSON, G ;
GIDLOF, A .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 269 (04) :H1496-H1500
[8]   Microvascular abnormalities in patients with vibration white finger [J].
Littleford, RC ;
Khan, F ;
Hindley, MO ;
Ho, M ;
Belch, JJF .
QJM-MONTHLY JOURNAL OF THE ASSOCIATION OF PHYSICIANS, 1997, 90 (08) :525-529
[9]  
LUGGEN M, 1995, J RHEUMATOL, V22, P2226
[10]  
MARCOLONGO R, 1997, MINERVA MED, V8, P307