Method transfer for fast liquid chromatography in pharmaceutical analysis: Application to short columns packed with small particle. Part I: Isocratic separation

被引:109
作者
Guillarme, Davy [1 ]
Nguyen, Dao T. -T. [1 ]
Rudaz, Serge [1 ]
Veuthey, Jean-Luc [1 ]
机构
[1] Univ Geneva, Univ Lausanne, Sch Pharmaceut Sci, Lab Analyt Pharmaceut Chem, CH-1211 Geneva 4, Switzerland
关键词
fast liquid chromatography; isocratic transfer; short columns; UPLC; sub-2 mu m particles;
D O I
10.1016/j.ejpb.2006.11.027
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Liquid chromatography (LC) is considered to be the gold standard in pharmaceutical analysis. Today, there is a need for fast and ultra-fast methods with good efficiency and resolution for achieving separations in few minutes or even seconds. The present work describes a simple methodology for performing a successful method transfer from conventional LC to fast and ultra-fast LC. In order to carry out fast separations, short columns (20-50 mm) packed with small particles (3.5 and 1.7 mu m) were used and their chromatographic performance was compared to that of a conventional column (150 mm, 5 mu m). For that purpose, an optimized LC system was employed to limit extra-column volumes which can have a dramatic impact on efficiency and resolution. This paper reports the fundamental equations used for transferring an isocratic chromatographic separation performed with a given column geometry and chemistry to a smaller column packed with similar or identical stationary phase, without influence on chromatographic performance. For this purpose, the flow rate and the injected volume need to be adapted. The effect of column length and particle size reduction on chromatographic resolution and analysis time was described for an isocratic separation. Using the method transfer equations, it is possible to predict the new conditions to be used, for fast and ultra-fast separations. In this work, ultra-fast separations were achieved thanks to a new generation of instrumentation (ultra performance liquid chromatography, UPLC) which uses simultaneously short column packed with sub-2 mu m particles and ultra-high pressure (up to 1000 bar). This work demonstrates an analysis time reduction up to a factor 12, compared to a conventional LC separation, without affecting the quality of separation. Therefore, the complete resolution of a pharmaceutical formulation was achieved in only a few seconds. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:475 / 482
页数:8
相关论文
共 21 条
  • [1] Ahuja S, 2005, SEP SCI TECHNOL-SER, V6, P1
  • [2] Applications of silica-based monolithic HPLC columns
    Cabrera, K
    [J]. JOURNAL OF SEPARATION SCIENCE, 2004, 27 (10-11) : 843 - 852
  • [3] Instrumental requirements for nanoscale liquid chromatography
    Chervet, JP
    Ursem, M
    Salzmann, JB
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (09) : 1507 - 1512
  • [4] The high throughput analysis of N-methyl carbamate pesticides in wine and juice by electrospray ionization liquid chromatography tandem mass spectrometry with direct sample injection into a short column
    Goto, T
    Ito, Y
    Oka, H
    Saito, I
    Matsumoto, H
    Sugiyama, H
    Ohkubo, C
    Nakazawa, H
    Nagase, H
    [J]. ANALYTICA CHIMICA ACTA, 2005, 531 (01) : 79 - 86
  • [5] Grumbach E, 2006, LC GC N AM, P80
  • [6] Detection modes with high temperature liquid chromatography - A review
    Guillarme, D.
    Heinisch, S.
    [J]. SEPARATION AND PURIFICATION REVIEWS, 2005, 34 (02) : 181 - 216
  • [7] Effect of temperature in reversed phase liquid chromatography
    Guillarme, D
    Heinisch, S
    Rocca, JL
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1052 (1-2) : 39 - 51
  • [8] Ishizuka N, 1998, HRC-J HIGH RES CHROM, V21, P477
  • [9] JOSEPH M, 2005, LC GC N AM, V23, P3
  • [10] High-throughput high-performance liquid chromatography/mass spectrometry for modern drug discovery
    Kyranos, JN
    Cai, H
    Wei, D
    Goetzinger, WK
    [J]. CURRENT OPINION IN BIOTECHNOLOGY, 2001, 12 (01) : 105 - 111