A calorimetric analysis of a polymer electrolyte fuel cell and the production of H2O2 at the cathode

被引:21
作者
Burheim, Odne [1 ]
Vie, Preben J. S. [2 ]
Moller-Holst, Steffen [3 ]
Pharoah, Jon [1 ]
Kjelstrup, Signe [1 ]
机构
[1] Inst Kjemi, N-7491 Trondheim, Norway
[2] Inst Energy Technol, N-2007 Kjeller, Norway
[3] Sintef Mat & Chem, N-7000 Trondheim, Norway
关键词
Hydrogen peroxide; H2O2; Calorimeter; Fuel cell; HYDROGEN-PEROXIDE; ENTROPY PRODUCTION; STABILITY; HEAT;
D O I
10.1016/j.electacta.2009.09.053
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A calorimeter has been constructed and used to measure the total heat production of a single polymer electrolyte fuel cell that is operated on hydrogen and oxygen at 50 degrees C and I bar. The cell had a SolviCore Catalyst Coated Backing and Nafion membranes 112,115 and 117. We report that the total heat production plus the power production corresponds to the enthalpy of formation of water for cell potentials above 0.55 V. For cell potentials less than 0.55 V, we measured a linear decrease in the reaction enthalpy with decreasing cell potential. This effect was obtained independently of membrane thickness and current density. We propose therefore that the main power loss at low cell potentials and the inflection point in the polarisation curve is due to hydrogen peroxide formation at the cathode. The total heat production was decomposed into reversible and irreversible effects (non-ohmic and ohmic). The non-ohmic part was evaluated using Tafel plots. We show that it is possible to determine the overpotential of an electrode also from its thermal signature. Crown Copyright (C) 2009 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:935 / 942
页数:8
相关论文
共 21 条
[1]  
Aylward G H., 2002, SI Chemical Data, V5th
[2]   Challenges and opportunities of thermal management issues related to fuel cell technology and modeling [J].
Faghri, A ;
Guo, Z .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (19-20) :3891-3920
[3]   Heat-treated iron(III) tetramethoxyphenyl porphyrin chloride supported on high-area carbon as an electrocatalyst for oxygen reduction: Part III. Detection of hydrogen-peroxide during oxygen reduction [J].
Gojkovic, SL ;
Gupta, S ;
Savinell, RF .
ELECTROCHIMICA ACTA, 1999, 45 (06) :889-897
[4]   From chemical processes to electrochemical processes: The key to minimal entropy production [J].
Hemmes, K ;
Dijkema, GPJ ;
van der Kooi, HJ .
RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2004, 40 (11) :1100-1104
[5]  
Kinoshita K., 1992, Electrochemical Oxygen Technology
[6]   Local and total entropy production and heat and water fluxes in a one-dimensional polymer electrolyte fuel cell [J].
Kjelstrup, S ;
Rosjorde, A .
JOURNAL OF PHYSICAL CHEMISTRY B, 2005, 109 (18) :9020-9033
[7]   Exploring single electrode reactions in polymer electrolyte fuel cells [J].
Kuhn, H. ;
Wokaun, A. ;
Scherer, G. G. .
ELECTROCHIMICA ACTA, 2007, 52 (06) :2322-2327
[8]   In situ detection of hydrogen peroxide in PEM fuel cells [J].
Liu, W ;
Zuckerbrod, D .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2005, 152 (06) :A1165-A1170
[9]   Electrochemical synthesis of hydrogen peroxide: Rotating disk electrode and fuel cell studies [J].
Lobyntseva, Elena ;
Kallio, Tanja ;
Alexeyeva, Nadezda ;
Tammeveski, Kaido ;
Kontturi, Kyoesti .
ELECTROCHIMICA ACTA, 2007, 52 (25) :7262-7269
[10]  
MOLLERHOLST S, 2006, 4 INT ASME C FUEL CE