Performance metrics of an optical spectral imaging system for intra-operative assessment of breast tumor margins

被引:57
作者
Bydlon, Torre M. [1 ]
Kennedy, Stephanie A. [1 ]
Richards, Lisa M. [1 ]
Brown, J. Quincy [1 ,4 ]
Yu, Bing [1 ,4 ]
Junker, Marlee K. [1 ,4 ]
Gallagher, Jennifer [2 ]
Geradts, Joseph [3 ]
Wilke, Lee G. [2 ]
Ramanujam, Nimmi [1 ,4 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[2] Duke Univ, Med Ctr, Dept Surg, Durham, NC 27704 USA
[3] Duke Univ, Med Ctr, Dept Pathol, Durham, NC 27710 USA
[4] Endls Opt, Res Triangle Pk, NC 27709 USA
来源
OPTICS EXPRESS | 2010年 / 18卷 / 08期
基金
美国国家卫生研究院;
关键词
DIFFUSE-REFLECTANCE SPECTROSCOPY; FROZEN-SECTION ANALYSIS; MONTE-CARLO; LUMPECTOMY MARGINS; CONSERVING SURGERY; POSITIVE MARGINS; SURGICAL MARGINS; LOCAL RECURRENCE; INVERSE MODEL; CANCER;
D O I
10.1364/OE.18.008058
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
As many as 20-70% of patients undergoing breast conserving surgery require repeat surgeries due to a close or positive surgical margin diagnosed post-operatively [1]. Currently there are no widely accepted tools for intra-operative margin assessment which is a significant unmet clinical need. Our group has developed a first-generation optical visible spectral imaging platform to image the molecular composition of breast tumor margins and has tested it clinically in 48 patients in a previously published study [2]. The goal of this paper is to report on the performance metrics of the system and compare it to clinical criteria for intra-operative tumor margin assessment. The system was found to have an average signal to noise ratio (SNR) > 100 and < 15% error in the extraction of optical properties indicating that there is sufficient SNR to leverage the differences in optical properties between negative and close/positive margins. The probe had a sensing depth of 0.5-2.2 mm over the wavelength range of 450-600 nm which is consistent with the pathologic criterion for clear margins of 0-2 mm. There was < 1% cross-talk between adjacent channels of the multi-channel probe which shows that multiple sites can be measured simultaneously with negligible cross-talk between adjacent sites. Lastly, the system and measurement procedure were found to be reproducible when evaluated with repeated measures, with a low coefficient of variation (< 0.11). The only aspect of the system not optimized for intra-operative use was the imaging time. The manuscript includes a discussion of how the speed of the system can be improved to work within the time constraints of an intra-operative setting. (c) 2010 Optical Society of America
引用
收藏
页码:8058 / 8076
页数:19
相关论文
共 35 条
[1]  
Abe O, 2005, LANCET, V366, P2087, DOI 10.1016/s0140-6736(05)66544-0
[2]   A Robust-Monte Carlo Model for the Extraction of Biological Absorption and Scattering In Vivo [J].
Bender, Janelle E. ;
Vishwanath, Karthik ;
Moore, Laura K. ;
Brown, J. Quincy ;
Chang, Vivide ;
Palmer, Gregory M. ;
Ramanujam, Nirmala .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (04) :960-968
[3]   Diagnosis of breast cancer using elastic-scattering spectroscopy: preliminary clinical results [J].
Bigio, IJ ;
Bown, SG ;
Briggs, G ;
Kelley, C ;
Lakhani, S ;
Pickard, D ;
Ripley, PM ;
Rose, IG ;
Saunders, C .
JOURNAL OF BIOMEDICAL OPTICS, 2000, 5 (02) :221-228
[4]   Role for intraoperative margin assessment in patients undergoing breast-conserving surgery [J].
Cabioglu, Neslihan ;
Hunt, Kelly K. ;
Sahin, Aysegul A. ;
Kuerer, Henry M. ;
Babiera, Gildy V. ;
Singletary, S. Eva ;
Whitman, Gary J. ;
Ross, Merrick I. ;
Ames, Frederick C. ;
Feig, Barry W. ;
Buchholz, Thomas A. ;
Meric-Bernstam, Funda .
ANNALS OF SURGICAL ONCOLOGY, 2007, 14 (04) :1458-1471
[5]   Accuracy of intraoperative frozen-section analysis of breast cancer lumpectomy-bed margins [J].
Cendán, JC ;
Coco, D ;
Copeland, EM .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2005, 201 (02) :194-198
[6]   Intraoperative margin assessment reduces reexcision rates in patients with ductal carcinoma in situ treated with breast-conserving surgery [J].
Chagpar, A ;
Yen, T ;
Sahin, A ;
Hunt, KK ;
Whitman, GJ ;
Ames, FC ;
Ross, MI ;
Meric-Bernstam, F ;
Babiera, GV ;
Singletary, SE ;
Kuerer, HM .
AMERICAN JOURNAL OF SURGERY, 2003, 186 (04) :371-377
[7]  
COX CE, 1991, ARCH SURG-CHICAGO, V126, P490
[8]  
Creager AJ, 2002, ARCH PATHOL LAB MED, V126, P846
[9]   Factors affecting successful breast conservation for ductal carcinoma in situ [J].
Dillon, Mary F. ;
Mc Dermott, Enda W. ;
O'Doherty, Ann ;
Quinn, Cecily M. ;
Hill, Arnold D. ;
O'Higgins, Niall .
ANNALS OF SURGICAL ONCOLOGY, 2007, 14 (05) :1618-1628
[10]   Local recurrence after breast-conserving therapy for invasive breast cancer: High incidence in young patients and association with poor survival [J].
Elkhuizen, PHM ;
van de Vijver, MJ ;
Hermans, J ;
Zonderland, HM ;
van de Velde, CJH ;
Leer, JWH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (04) :859-867