Recent advances in polymeric monolithic stationary phases for electrochromatography in capillaries and chips

被引:79
作者
Bedair, M [1 ]
El Rassi, Z [1 ]
机构
[1] Oklahoma State Univ, Dept Chem, Stillwater, OK 74078 USA
关键词
capillary electrochromatography; polymeric monoliths; review; stationary phases;
D O I
10.1002/elps.200406136
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This review article summarizes the advances made over the last two years in polymeric monoliths for capillary electrochromatography (CEC). It covers the scientific literature in the period extending form the second half of 2002 until the end of first half of 2004. Currently, there is an increasing interest in monolithic stationary phases in CEC as an alternative to particulate packed capillary columns due in major part to the simplicity of the in situ preparation of monolithic stationary phases and the availability of a wide chemistry for surface ligands, which allow for tailoring the chromatographic sorbent needed for solving a given separation problem(s). The various approaches, formats, and chemistries used for the preparation of monolithic stationary phases are described.
引用
收藏
页码:4110 / 4119
页数:10
相关论文
共 45 条
[1]   Protein separation by monolithic capillary electrochromatography [J].
Bandilla, D ;
Skinner, CD .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1004 (1-2) :167-179
[2]  
Bedair M, 2002, ELECTROPHORESIS, V23, P2938, DOI 10.1002/1522-2683(200209)23:17<2938::AID-ELPS2938>3.0.CO
[3]  
2-8
[4]   Capillary electrochromatography with monolithic stationary phases - II. Preparation of cationic stearyl-acrylate monoliths and their electrochromatographic characterization [J].
Bedair, M ;
El Rassi, Z .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1013 (1-2) :35-45
[5]   Capillary electrochromatography with monolithic stationary phases - III. Evaluation of the electrochromatographic retention of neutral and charged solutes on cationic stearyl-acrylate monoliths and the separation of water-soluble proteins and membrane proteins [J].
Bedair, M ;
El Rassi, Z .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1013 (1-2) :47-56
[6]  
Buszewski B, 2002, LC GC EUR, V15, P792
[7]   Polymerised bicontinuous microemulsions as stationary phases for capillary electrochromatography [J].
Cameron, NR ;
Flook, KJ ;
Wren, SAC .
CHROMATOGRAPHIA, 2003, 57 (3-4) :203-206
[8]  
Deneanu A, 2002, J SEP SCI, V25, P1252
[9]   Comparison of the chromatographic behavior of monolithic capillary columns in capillary electrochromatography and nano-high-performance liquid chromatography [J].
Freitag, R .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1033 (02) :267-273
[10]   Streaming potential in open and packed fused-silica capillaries [J].
Gusev, I ;
Horváth, C .
JOURNAL OF CHROMATOGRAPHY A, 2002, 948 (1-2) :203-223