410-nm diode laser cavity ring-down spectroscopy for trace detection of NO2

被引:50
作者
Mazurenka, MI [1 ]
Fawcett, BL [1 ]
Elks, JMF [1 ]
Shallcross, DE [1 ]
Orr-Ewing, AJ [1 ]
机构
[1] Univ Bristol, Sch Chem, Bristol BS8 1TS, Avon, England
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1016/S0009-2614(02)01652-4
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The detection of NO2 at sub part per billion by volume (ppbv) concentrations has been demonstrated using a cavity ring-down spectrometer with a blue diode laser operating at wavelengths close to 410 nm. Measurements at peaks in the absorption spectrum at wavelengths of 410.4955 and 410.3533 nm demonstrate a minimum detectable number density of NO2 of 9.8 x 10(9) molecules cm(-3), which would correspond to 0.4 ppbv under atmospheric conditions in the lower troposphere. Additional experiments performed with a pulsed, tuneable dye laser system provide absorption cross-sections for NO2 over the restricted wavelength ranges of 408.5-410.5 and 435.0-435.5 nm, but at a resolution of similar to0.06 cm(-1) that is higher than previously reported and close to the Doppler broadening limit at 295 K. These spectra show considerably more structure than is evident in published Fourier transform (FT) spectra obtained at lower resolution, but yield cross-sections that are in quantitative agreement with the FT measurements. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 33 条
[1]   OH detection by absorption of frequency-doubled diode laser radiation at 308 nm [J].
Barry, HR ;
Bakowski, B ;
Corner, L ;
Freegarde, T ;
Hawkins, OTW ;
Hancock, G ;
Jacobs, RMJ ;
Peverall, R ;
Ritchie, GAD .
CHEMICAL PHYSICS LETTERS, 2000, 319 (1-2) :125-130
[2]   Cavity-enhanced absorption spectroscopy of methane at 1.73 μm [J].
Barry, HR ;
Corner, L ;
Hancock, G ;
Peverall, R ;
Ritchie, GAD .
CHEMICAL PHYSICS LETTERS, 2001, 333 (3-4) :285-289
[3]   Cavity ring-down spectroscopy: Experimental schemes and applications [J].
Berden, G ;
Peeters, R ;
Meijer, G .
INTERNATIONAL REVIEWS IN PHYSICAL CHEMISTRY, 2000, 19 (04) :565-607
[4]   Photofragmentation two-photon laser-induced fluorescence detection of NO2 and NO:: Comparison of measurements with model results based on airborne observations during PEM-Tropics A [J].
Bradshaw, J ;
Davis, D ;
Crawford, J ;
Chen, G ;
Shetter, R ;
Müller, M ;
Gregory, G ;
Sachse, G ;
Blake, D ;
Heikes, B ;
Singh, H ;
Mastromarino, J ;
Sandholm, S .
GEOPHYSICAL RESEARCH LETTERS, 1999, 26 (04) :471-474
[5]  
Czyzewski A, 2002, ACTA PHYS POL B, V33, P2255
[6]   Cavity enhanced absorption and cavity enhanced magnetic rotation spectroscopy [J].
Engeln, R ;
Berden, G ;
Peeters, R ;
Meijer, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (11) :3763-3769
[7]  
FAWCETT BL, IN PRESS PHYS CHEM C
[8]   A laser induced fluorescence instrument for measuring tropospheric NO2 [J].
Fong, C ;
Brune, WH .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (11) :4253-4262
[9]   High-resolution cavity ring-down absorption spectroscopy of nitrous oxide and chloroform using a near-infrared cw diode laser [J].
He, YB ;
Hippler, M ;
Quack, M .
CHEMICAL PHYSICS LETTERS, 1998, 289 (5-6) :527-534
[10]   High-resolution Fourier transform infrared and cw-diode laser cavity ringdown spectroscopy of the ν2+2ν3 band of methane near 7510 cm-1 in slit jet expansions and at room temperature [J].
Hippler, M ;
Quack, M .
JOURNAL OF CHEMICAL PHYSICS, 2002, 116 (14) :6045-6055