Measurement of calcitonin by immunoassay analyzers

被引:34
作者
Bieglmayer, Christian
Vierhapper, Heinrich
Dudczak, Robert
Niederle, Bruno
机构
[1] Gen Hosp Med Univ & City Vienna, Clin Inst Med & Chem Lab Diagnost, A-1090 Vienna, Austria
[2] Gen Hosp Med Univ & City Vienna, Clin Internal Med, Dept Endocrinol & Metab, A-1090 Vienna, Austria
[3] Gen Hosp Med Univ & City Vienna, Clin Nucl Med, A-1090 Vienna, Austria
[4] Gen Hosp Med Univ & City Vienna, Div Gen Surg, Surg Endocrinol Sect, A-1090 Vienna, Austria
关键词
auto-analyzer; calcitonin; method comparison;
D O I
10.1515/CCLM.2007.124
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Since Nichols Institute Diagnostics (NID) ended production of their automated calcitonin immunoassay, evaluation of an alternative calcitonin assay was necessary. Methods: Calcitonin measured by the NID procedure was compared with a test from Diagnostic Products Corporation (DPC). Calcitonin was also measured by assays from DiaSorin (DS) and Scantibodies (SC). Results: In 187 samples, detection failed either by NID (39%) or DPC (96%) assay; in 35% of samples, the tests agreed for non-measurable calcitonin. The regression line DPC=0.78xNID-0.3 (r=0.998) fitted results from 236 samples with detectable calcitonin. A linear relationship, albeit with scattering at low concentrations, was observed. Importantly, stimulation by pentagastrin above basal calcitonin concentrations yielded similar results with both assays. Comparisons (DPC=0.80xDS-3.4 and DPC=0.81XSC-1.1) confirmed an aberrant calibration of the DPC test. To overcome the method bias, we propose a multiplication factor of 0.8 to convert NID to DPC results. Conclusions: Apparently due to non-specific effects, the DS and SC assays produced calcitonin results in samples from completely thyroidectomized patients, while the DPC assay correctly failed to detect calcitonin. Thus, the DPC assay on an Immulitel 2000 analyzer may be used as a more accurate substitute for NID if the different calibration is noted.
引用
收藏
页码:662 / 666
页数:5
相关论文
共 20 条
[1]   CALCITONIN - PHYSIOLOGY AND PATHO-PHYSIOLOGY [J].
AUSTIN, LA ;
HEATH, H .
NEW ENGLAND JOURNAL OF MEDICINE, 1981, 304 (05) :269-278
[2]  
BABLOK W, 1988, J CLIN CHEM CLIN BIO, V26, P783
[3]  
Bieglmayer C, 2002, WIEN KLIN WOCHENSCHR, V114, P267
[4]  
Bieglmayer C, 2002, J ENDOCRINOL INVEST, V25, P197, DOI 10.1007/BF03343987
[5]   Calcitonin precursor levels in human medullary thyroid carcinoma [J].
Bihan, H ;
Becker, KL ;
Snider, RH ;
Nylen, E ;
Vittaz, L ;
Lauret, C ;
Modigliani, E ;
Moretti, JL ;
Cohen, R .
THYROID, 2003, 13 (08) :819-822
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]   ESTIMATES OF CIRCULATING MONOMERIC CALCITONIN - PHYSIOLOGICAL-STUDIES IN NORMAL AND THYROIDECTOMIZED MAN [J].
BODY, JJ ;
HEATH, H .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1983, 57 (05) :897-903
[8]  
BOSCATO LM, 1988, CLIN CHEM, V34, P27
[9]   GEL CHROMATOGRAPHY OF IMMUNOEXTRACTED PLASMA CALCITONIN IN RESPONSE TO THE CALCIUM CLAMP IN HEALTHY-MALES [J].
BUCHT, E ;
TORRING, O ;
SJOBERG, HE .
ACTA ENDOCRINOLOGICA, 1985, 110 (03) :421-428
[10]   SERUM CALCITONIN FORMS AND CONCENTRATIONS IN YOUNG AND ELDERLY HEALTHY FEMALES [J].
BUCHT, E ;
RONG, H ;
SJOBERG, HE ;
GRANBERG, B ;
TORRING, O ;
SJOSTEDT, U .
CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (01) :32-37