Cardiac functional analysis with multi-detector row CT and segmental reconstruction algorithm: Comparison with echocardiography, SPECT, and MR imaging

被引:162
作者
Yamamuro, M
Tadamura, E
Kubo, S
Toyoda, H
Nishina, T
Ohba, M
Hosokawa, R
Kimura, T
Tamaki, N
Komeda, M
Kita, T
Konishi, J
机构
[1] Kyoto Univ, Grad Sch Med, Dept Nucl Med & Diagnost Imaging, Sakyo Ku, Kyoto 6068507, Japan
[2] Kyoto Univ, Grad Sch Med, Dept Cardiovasc Surg, Sakyo Ku, Kyoto 6068507, Japan
[3] Kyoto Univ, Grad Sch Med, Dept Cardiovasc Med, Sakyo Ku, Kyoto 6068507, Japan
[4] Hokkaido Univ, Grad Sch Med, Dept Nucl Med, Sapporo, Hokkaido, Japan
关键词
D O I
10.1148/radiol.2342031271
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate accuracy of cardiac functional analysis with multi-detector row computed tomography (CT) and segmental reconstruction algorithm over a range of heart rates. MATERIALS AND METHODS: Institutional review board approval was obtained. Informed consent was not required. Multi-detector row CT (500-msec rotation time, 8 x 1-mm detector collimation) and magnetic resonance (MR) imaging were performed in 50 patients (28 men, 22 women, age range, 46-84 years; mean age, 67 years). Two-dimensional echocardiography was performed in 41 patients,l and electrocardiographically (ECG)-gated single photon emission computed tomography (SPECT) was performed in 27. End-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), and left ventricular (LV) mass were estimated with multi-detector row CT and compared wit values estimated with MR imaging, which served as the reference standard. Additionally, EF values estimated with multi-detector row CT, echocardiography, and SPECT were compared with those estimated wit MR imaging. Systemic error and degree of agreement of global functional parameters measured with MR imaging and other modalities were assessed. In a second analysis, linear regression analysis was added. RESULTS: EF estimate with multi-detector row CT agreed and correlated well with EF estimated with MR imaging (bias +/- standard deviation, -1.2% +/- 4.6; r = 0.96). Agreement and correlation were similar for EDV (-0.35 mL +/- 15.2; r = 0.97), ESV (1.1 mL +/- 8.6; r = 0.99), and LV mass (2.5 mL +/- 15.0, r = 0.96). Standard deviation of EF difference between multi-detector row CT and MR imaging was significantly less than than between echocardiography and MR imaging (P < .001) or that between SPECT and MR imaging (P < .001). CONCLUSION: Various: LV functional parameters were measured with multi-detector row CT with a segmental approach, and measurements correlated and agreed with those obtained with MR imaging. Moreover, functional analysis with multi-detector row CT was more accurate than that with two-dimensional echocardiography or ECG-gated SPECT.
引用
收藏
页码:381 / 390
页数:10
相关论文
共 48 条
[1]  
Achenbach S, 2001, CIRCULATION, V103, P2535
[2]   MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study [J].
Barkhausen, J ;
Ruehm, SG ;
Goyen, M ;
Buck, T ;
Laub, G ;
Debatin, JF .
RADIOLOGY, 2001, 219 (01) :264-269
[3]   Left ventricular function: Correlation of quantitative gated SPECT and MR imaging over a wide range of values [J].
Bavelaar-Croon, CDL ;
Kayser, HWM ;
van der Wall, EE ;
de Roos, A ;
Dibbets-Schneider, P ;
Pauwels, EKJ ;
Germano, G ;
Atsma, DE .
RADIOLOGY, 2000, 217 (02) :572-575
[4]   Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance - Are they interchangeable? [J].
Bellenger, NG ;
Burgess, MI ;
Ray, SG ;
Lahiri, A ;
Coats, AJS ;
Cleland, JGF ;
Pennell, DJ .
EUROPEAN HEART JOURNAL, 2000, 21 (16) :1387-1396
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]  
Buck T, 1997, CIRCULATION, V96, P4286
[7]   Cine MR angiography of the heart with segmented true fast imaging with steady-state precession [J].
Carr, JC ;
Simonetti, O ;
Bundy, J ;
Li, DB ;
Pereles, S ;
Finn, JP .
RADIOLOGY, 2001, 219 (03) :828-834
[8]   Magnetic resonance imaging of ischemic heart disease: Why cardiac magnetic resonance imaging will play a significant role in the management of patients with coronary artery disease [J].
de Roos, A ;
Kunz, P ;
Lamb, H ;
Kroft, L ;
Langerak, S ;
Doornbos, J ;
van der Wall, E .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 :S135-S141
[9]   Usefulness of dynamic multislice computed tomography of left ventricular function in unstable angina pectoris and comparison with echocardiography [J].
Dirksen, MS ;
Bax, JJ ;
de Roos, A ;
Jukema, JW ;
van der Geest, RJ ;
Geleijns, K ;
Boersma, E ;
van der Wall, EE ;
Lamb, HJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (10) :1157-+
[10]   Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart [J].
Flohr, T ;
Ohnesorge, B .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) :907-923