Cardiac functional analysis with multi-detector row CT and segmental reconstruction algorithm: Comparison with echocardiography, SPECT, and MR imaging

被引:162
作者
Yamamuro, M
Tadamura, E
Kubo, S
Toyoda, H
Nishina, T
Ohba, M
Hosokawa, R
Kimura, T
Tamaki, N
Komeda, M
Kita, T
Konishi, J
机构
[1] Kyoto Univ, Grad Sch Med, Dept Nucl Med & Diagnost Imaging, Sakyo Ku, Kyoto 6068507, Japan
[2] Kyoto Univ, Grad Sch Med, Dept Cardiovasc Surg, Sakyo Ku, Kyoto 6068507, Japan
[3] Kyoto Univ, Grad Sch Med, Dept Cardiovasc Med, Sakyo Ku, Kyoto 6068507, Japan
[4] Hokkaido Univ, Grad Sch Med, Dept Nucl Med, Sapporo, Hokkaido, Japan
关键词
D O I
10.1148/radiol.2342031271
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate accuracy of cardiac functional analysis with multi-detector row computed tomography (CT) and segmental reconstruction algorithm over a range of heart rates. MATERIALS AND METHODS: Institutional review board approval was obtained. Informed consent was not required. Multi-detector row CT (500-msec rotation time, 8 x 1-mm detector collimation) and magnetic resonance (MR) imaging were performed in 50 patients (28 men, 22 women, age range, 46-84 years; mean age, 67 years). Two-dimensional echocardiography was performed in 41 patients,l and electrocardiographically (ECG)-gated single photon emission computed tomography (SPECT) was performed in 27. End-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), and left ventricular (LV) mass were estimated with multi-detector row CT and compared wit values estimated with MR imaging, which served as the reference standard. Additionally, EF values estimated with multi-detector row CT, echocardiography, and SPECT were compared with those estimated wit MR imaging. Systemic error and degree of agreement of global functional parameters measured with MR imaging and other modalities were assessed. In a second analysis, linear regression analysis was added. RESULTS: EF estimate with multi-detector row CT agreed and correlated well with EF estimated with MR imaging (bias +/- standard deviation, -1.2% +/- 4.6; r = 0.96). Agreement and correlation were similar for EDV (-0.35 mL +/- 15.2; r = 0.97), ESV (1.1 mL +/- 8.6; r = 0.99), and LV mass (2.5 mL +/- 15.0, r = 0.96). Standard deviation of EF difference between multi-detector row CT and MR imaging was significantly less than than between echocardiography and MR imaging (P < .001) or that between SPECT and MR imaging (P < .001). CONCLUSION: Various: LV functional parameters were measured with multi-detector row CT with a segmental approach, and measurements correlated and agreed with those obtained with MR imaging. Moreover, functional analysis with multi-detector row CT was more accurate than that with two-dimensional echocardiography or ECG-gated SPECT.
引用
收藏
页码:381 / 390
页数:10
相关论文
共 48 条
[11]  
GERMANO G, 1995, J NUCL MED, V36, P2138
[12]   REPRODUCIBILITY OF LEFT-VENTRICULAR VOLUMES BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY [J].
GORDON, EP ;
SCHNITTGER, I ;
FITZGERALD, PJ ;
WILLIAMS, P ;
POPP, RL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 2 (03) :506-513
[13]  
Halliburton SS, 2002, RADIOLOGY, V225, P389
[14]  
Heusch A, 1999, Eur J Ultrasound, V9, P245, DOI 10.1016/S0929-8266(99)00032-4
[15]   WHICH STANDARD HAS THE GOLD [J].
HIGGINS, CB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (07) :1608-1609
[16]   Coronary artery calcium: Absolute quantification in nonenhanced and contrast-enhanced multi-detector row CT studies [J].
Hong, C ;
Becker, CR ;
Schoepf, UJ ;
Ohnesorge, B ;
Bruening, R ;
Reiser, MF .
RADIOLOGY, 2002, 223 (02) :474-480
[17]   ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality [J].
Hong, C ;
Becker, CR ;
Huber, A ;
Schoepf, UJ ;
Ohnesorge, B ;
Knez, A ;
Brüning, R ;
Reiser, MF .
RADIOLOGY, 2001, 220 (03) :712-717
[18]   Quantification of coronary artery calcium using multidetector CT and a retrospective ECG-gating reconstruction algorithm [J].
Horiguchi, J ;
Nakanishi, T ;
Ito, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (06) :1429-1435
[19]   Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation [J].
Jakobs, TF ;
Becker, CR ;
Ohnesorge, B ;
Flohr, T ;
Suess, C ;
Schoepf, UJ ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2002, 12 (05) :1081-1086
[20]   Using ECG-gated multicletector CT to evaluate global left ventricular myocardial function in patients with coronary artery disease [J].
Juergens, KU ;
Grude, M ;
Fallenberg, EM ;
Opitz, C ;
Wichter, T ;
Heindel, W ;
Fischbach, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (06) :1545-1550