A compact x-ray system for macromolecular crystallography

被引:9
作者
Gubarev, M
Ciszak, E [1 ]
Ponomarev, I
Gibson, W
Joy, M
机构
[1] NASA, George C Marshall Space Flight Ctr, Huntsville, AL 35812 USA
[2] Natl Res Council, Huntsville, AL 35812 USA
[3] Univ Space Res Assoc, Huntsville, AL 35805 USA
[4] Xray Opt Syst Inc, Albany, NY 12203 USA
[5] SUNY Albany, Ctr Xray Opt, Albany, NY 12222 USA
关键词
D O I
10.1063/1.1311937
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe the design and performance of a high flux x-ray system for a macromolecular crystallography that combines a microfocus x-ray generator (40 mu m full width at half maximum spot size at a power level of 46.5 W) and a collimating polycapillary optic. The Cu K alpha x-ray flux produced by this optimized system through a 500 mu m diam orifice is 7.0 times greater than the x-ray flux previously reported by Gubarev [M. Gubarev , J. Appl. Crystallogr. 33, 882 (2000)]. The x-ray flux from the microfocus system is also 2.6 times higher than that produced by a rotating anode generator equipped with a graded multilayer monochromator (green optic, Osmic, Inc. CMF24-48-Cu6) and 40% less than that produced by a rotating anode generator with the newest design of graded multilayer monochromator (blue optic, Osmic, Inc. CMF12-38-Cu6). Both rotating anode generators operate at a power level of 5000 W, dissipating more than 100 times the power of our microfocus x-ray system. Diffraction data collected from small test crystals are of high quality. For example, 42 540 reflections collected at ambient temperature from a lysozyme crystal yielded R-sym=5.0% for data extending to 1.70 Angstrom, and 4.8% for the complete set of data to 1.85 Angstrom. The amplitudes of the observed reflections were used to calculate difference electron density maps that revealed positions of structurally important ions and water molecules in the crystal of lysozyme using the phases calculated from the protein model. (C) 2000 American Institute of Physics. [S0034- 6748(00)01211-9].
引用
收藏
页码:3900 / 3904
页数:5
相关论文
共 12 条
[1]   FOCUSING OPTICS FOR LABORATORY SOURCES IN X-RAY CRYSTALLOGRAPHY [J].
ARNDT, UW .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1990, 23 :161-168
[2]   Crystallography & NMR system:: A new software suite for macromolecular structure determination [J].
Brunger, AT ;
Adams, PD ;
Clore, GM ;
DeLano, WL ;
Gros, P ;
Grosse-Kunstleve, RW ;
Jiang, JS ;
Kuszewski, J ;
Nilges, M ;
Pannu, NS ;
Read, RJ ;
Rice, LM ;
Simonson, T ;
Warren, GL .
ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 1998, 54 :905-921
[3]   SETOR - HARDWARE-LIGHTED 3-DIMENSIONAL SOLID MODEL REPRESENTATIONS OF MACROMOLECULES [J].
EVANS, SV .
JOURNAL OF MOLECULAR GRAPHICS, 1993, 11 (02) :134-&
[4]   AN OPTICALLY FOCUSING X-RAY DIFFRACTION CAMERA [J].
FRANKS, A .
PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON SECTION B, 1955, 68 (12) :1054-+
[5]   First results from a macromolecular crystallography system with a polycapillary collimating optic and a microfocus X-ray generator [J].
Gubarev, M ;
Ciszak, E ;
Ponomarev, I ;
Gibson, W ;
Joy, M .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2000, 33 (02) :882-887
[6]   Stationary crystal diffraction with a monochromatic convergent X-ray source and application for macromolecular crystal data collection [J].
Ho, JX ;
Snell, EH ;
Sisk, RC ;
Ruble, JR ;
Carter, DC ;
Owens, SM ;
Gibson, WM .
ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 1998, 54 :200-214
[7]   MULTIPLE REFLECTION FROM SURFACE X-RAY OPTICS [J].
KUMAKHOV, MA ;
KOMAROV, FF .
PHYSICS REPORTS-REVIEW SECTION OF PHYSICS LETTERS, 1990, 191 (05) :289-350
[8]   Applications of polycapillary X-ray optics in protein crystallography [J].
Li, PW ;
Bi, RC .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1998, 31 (31) :806-811
[9]   Processing of X-ray diffraction data collected in oscillation mode [J].
Otwinowski, Z ;
Minor, W .
MACROMOLECULAR CRYSTALLOGRAPHY, PT A, 1997, 276 :307-326
[10]  
*RCSB PROT DAT BAN, 193L RCSB PROT DAT B