The use of vicryl mesh in 200 porous orbital implants - A technique with few exposures

被引:40
作者
Jordan, DR
Klapper, SR
Gilberg, SM
机构
[1] Univ Ottawa, Inst Eye, Ottawa, ON, Canada
[2] Aesthet Eye Surg, Indianapolis, IN USA
关键词
D O I
10.1097/00002341-200301000-00007
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Purpose: To report the results of a wrapping technique for porous orbital implants by using polyglactin 910 (Vicryl) mesh (Ethicon Inc., Somerville, NJ, U.S.A.) Methods: We retrospectively reviewed the records of 200 consecutive patients from one author's practice who received a polyglactin 910 mesh-wrapped porous orbital implant after enucleation or as a secondary implant between October 1, 1996, and April 15, 2001. We recorded potential problems that might be attributed to polyglactin 910 mesh both before pegging (excessive inflammatory response to the material, conjunctival thinning, and implant exposure) and after pegging (exposure of the implant around the sleeve, conjunctival thinning. and implant exposure other than adjacent to the peg). Results: One hundred twenty-two men and 78 women underwent placement of a polyglactin 910 mesh-wrapped porous orbital implant. The average age at the time of implantation was 48.9 years (range, 11 to 85 years). The average follow-up interval in the 200 patients was 19.4 months (range, 2 to 80 months). Thirteen of the 200 patients had less than 6 months of follow-up. leaving 187 patients with an average follow-up of 20.5 months (range, 6 to 80 months). There were 76 primary enucleations and 124 secondary orbital implants. Thirty-seven patients received a Bio-Eye hydroxyapatite implant (HA) (Integrated Orbital Implants, San Diego, Calif), 97 received a synthetic FCI3 hydroxyapatite implant (FCI, Issy-Les-Moutineaux, France), and 66 received a Bioceramic implant (aluminum oxide-Al2O3) (FCI. Issy-Les-Moulineaux, France). One hundred fourteen patients (57%) underwent peg placement. The average time to pegging was 9.9 months (range, 6 to 16 months). Before pegging. 4 of 187 patients (2.1%) had implant exposure. Three of these exposures followed secondary, orbital implant placement (2 Bio-Eye HA, 1 synthetic FCI3 HA) and one followed an enucleation (synthetic FCI3 HA). Two patients required a temporalis fascia graft and one required a scleral patchy the remaining defect closed spontaneously. One patient had conjunctival thinning 6 months after orbital implantation, which remained stable with no frank exposure for 36 months, No patient had excess socket inflammation, After peg placement, 3 additional patients had exposure of the implant around the peg site, There were no cases of conjunctival thinning or exposure of the implant other than adjacent to the peg site. Conclusions: Polyglactin 910 mesh is an excellent option as a wrapping material for porous orbital implants. It is simple to use, readily available. eliminates the need for donor tissue, does not require a second operative site, and it is less expensive than other currently available wrapping materials. We attribute Our high success rate to Our technique, which emphasizes proper placement of the implant within the Tenon space, suturing the extraocular muscles anterior to their normal anatomic sites, and meticulous closure of the Tenon capsule and conjunctiva in separate layers.
引用
收藏
页码:53 / 61
页数:9
相关论文
共 73 条
[1]
AHFELD SK, 1987, AM J SPORTS MED, V15, P336
[2]
ARNDT M, 1985, ACTA CHIR SCAND, V151, P93
[3]
BOVINE SPONGIFORM ENCEPHALOPATHY (BSE) - THE CURRENT SITUATION AND RESEARCH [J].
BRADLEY, R .
EUROPEAN JOURNAL OF EPIDEMIOLOGY, 1991, 7 (05) :532-544
[5]
COMPARISON OF PROSTHETIC MATERIALS FOR ABDOMINAL-WALL RECONSTRUCTION IN THE PRESENCE OF CONTAMINATION AND INFECTION [J].
BROWN, GL ;
RICHARDSON, JD ;
MALANGONI, MA ;
TOBIN, GR ;
ACKERMAN, D ;
POLK, HC .
ANNALS OF SURGERY, 1985, 201 (06) :705-711
[6]
TISSUE BREAKDOWN AND EXPOSURE ASSOCIATED WITH ORBITAL HYDROXYAPATITE IMPLANTS [J].
BUETTNER, H ;
BARTLEY, GB .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1992, 113 (06) :669-673
[7]
NEUROSURGICAL USE OF HUMAN DURA-MATER STERILIZED BY GAMMA-RAYS AND STORED IN ALCOHOL - LONG-TERM RESULTS [J].
CANTORE, G ;
GUIDETTI, B ;
DELFINI, R .
JOURNAL OF NEUROSURGERY, 1987, 66 (01) :93-95
[8]
Gore-Tex as an orbital implant material [J].
Cas, RD ;
Maus, M ;
Bilyk, J ;
Chang, W ;
Eagle, RC ;
Rubin, P .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 14 (06) :425-431
[9]
Exposure of expanded polytetrafluoroethylene-wrapped hydroxyapatite orbital implant: A report of two patients [J].
Choo, PH ;
Carter, SR ;
Crawford, JB ;
Seiff, SR .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1999, 15 (02) :77-78
[10]
Christmas NJ, 2000, ARCH OPHTHALMOL-CHIC, V118, P503