Accuracy comparison of absolute optical frequency measurement between harmonic-generation synthesis and a frequency-division femtosecond comb

被引:73
作者
Ye, J [1 ]
Yoon, TH
Hall, JL
Madej, AA
Bernard, JE
Siemsen, KJ
Marmet, L
机构
[1] NIST, Quantum Phys Div, Boulder, CO 80309 USA
[2] KRISS, Taejon 305600, South Korea
[3] Univ Colorado, Joint Inst Lab Astrophys, Boulder, CO 80309 USA
[4] Natl Res Council Canada, Inst Natl Measurement Stand, Ottawa, ON K1A 0R6, Canada
[5] Bur Int Poids & Mesures, F-92312 Sevres, France
关键词
D O I
10.1103/PhysRevLett.85.3797
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Using an iodine-stabilized He-Ne laser as a transfer oscillator, we compare absolute measurements of the optical frequency from a traditional frequency synthesis chain based on harmonic generation and from the frequency division technique of an ultrawide bandwidth femtosecond frequency comb. The agreement between these two measurements, both linked to the Cs standard, is 220 +/- 770 Hz, yielding a measure ment accuracy of 1.6 x 10(-12). We report 473 612 353 604.8 +/- 1.2 kHz as a preliminary updated value of the absolute frequency of the "f" component for the He-Ne laser international standard at 633 nm.
引用
收藏
页码:3797 / 3800
页数:4
相关论文
共 21 条
[1]   A CO2 TO VISIBLE OPTICAL FREQUENCY-SYNTHESIS CHAIN - ACCURATE MEASUREMENT OF THE 473 THZ HENE/I2 LASER [J].
ACEF, O ;
ZONDY, JJ ;
ABED, M ;
ROVERA, DG ;
GERARD, AH ;
CLAIRON, A ;
LAURENT, P ;
MILLERIOUX, Y ;
JUNCAR, P .
OPTICS COMMUNICATIONS, 1993, 97 (1-2) :29-34
[2]   Cs-based frequency measurement of a single, trapped ton transition in the visible region of the spectrum [J].
Bernard, JE ;
Madej, AA ;
Marmet, L ;
Whitford, BG ;
Siemsen, KJ ;
Cundy, S .
PHYSICAL REVIEW LETTERS, 1999, 82 (16) :3228-3231
[3]   Direct link between microwave and optical frequencies with a 300 THz femtosecond laser comb [J].
Diddams, SA ;
Jones, DJ ;
Ye, J ;
Cundiff, ST ;
Hall, JL ;
Ranka, JK ;
Windeler, RS ;
Holzwarth, R ;
Udem, T ;
Hänsch, TW .
PHYSICAL REVIEW LETTERS, 2000, 84 (22) :5102-5105
[4]   Stabilization and frequency measurement of the I2-stabilized Nd:YAG laser [J].
Hall, JL ;
Ma, LS ;
Taubman, M ;
Tiemann, B ;
Hong, FL ;
Pfister, O ;
Ye, J .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (02) :583-586
[5]   DIRECT FREQUENCY-MEASUREMENT OF THE I2-STABILIZED HE-NE 473-THZ (633-NM) LASER [J].
JENNINGS, DA ;
POLLOCK, CR ;
PETERSEN, FR ;
DRULLINGER, RE ;
EVENSON, KM ;
WELLS, JS ;
HALL, JL ;
LAYER, HP .
OPTICS LETTERS, 1983, 8 (03) :136-138
[6]   Carrier-envelope phase control of femtosecond mode-locked lasers and direct optical frequency synthesis [J].
Jones, DJ ;
Diddams, SA ;
Ranka, JK ;
Stentz, A ;
Windeler, RS ;
Hall, JL ;
Cundiff, ST .
SCIENCE, 2000, 288 (5466) :635-639
[7]   Linking the 474 THz HeNe/I2 standard to the 445 THz single Sr+ trapped ion standard:: Heterodyne frequency measurements using an OsO4 stabilized 29 THz laser system [J].
Madej, AA ;
Siemsen, KJ ;
Marmet, L ;
Bernard, JE ;
Acef, O .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (02) :553-557
[8]  
MADEJ AA, 2000, FREQUENCY MEASUREMEN, V79
[9]   PRECISE FREQUENCY-MEASUREMENT OF THE 2S-8S/8D TRANSITIONS IN ATOMIC-HYDROGEN - NEW DETERMINATION OF THE RYDBERG CONSTANT [J].
NEZ, F ;
PLIMMER, MD ;
BOURZEIX, S ;
JULIEN, L ;
BIRABEN, F ;
FELDER, R ;
ACEF, O ;
ZONDY, JJ ;
LAURENT, P ;
CLAIRON, A ;
ABED, M ;
MILLERIOUX, Y ;
JUNCAR, P .
PHYSICAL REVIEW LETTERS, 1992, 69 (16) :2326-2329
[10]   Practical realization of the definition of the metre (1997) [J].
Quinn, TJ .
METROLOGIA, 1999, 36 (03) :211-244