Adhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic foldable materials: an experimental study

被引:176
作者
Oshika, T
Nagata, T
Ishii, Y
机构
[1] Univ Tokyo, Sch Med, Dept Ophthalmol, Bunkyo Ku, Tokyo 1130033, Japan
[2] Hamamatsu Univ Sch Med, Dept Ophthalmol, Shizuoka, Japan
[3] Shinkawabashi Gen Hosp, Eye Clin, Kanagawa, Japan
关键词
D O I
10.1136/bjo.82.5.549
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims-To investigate the adhesion characteristics of several intraocular lenses (IOLs) to the simulated and rabbit lens capsule. Methods-Adhesive force to bovine collagen sheets was measured in water with polymethylmethacrylate (PMMA), three piece silicone, and acrylic foldable IOLs. In rabbit eyes, phacoemulsification and IOL implantation were performed. Three weeks later, adhesion between the anterior/posterior capsules and IOL optic was tested, and the capsule was examined histologically. Results-The mean adhesive force to the collagen sheet was 1697 (SD 286) mg for acrylic foldable, 583 (49) mg for PMMA, and 0 mg for silicons IOLs (p=0.0003, Kruskal-Wallis test). Scores (0-5) of adhesion between rabbit anterior capsule and IOL optic were 4.50 (0.55) for acrylic foldable, 3.20 (0.84) for PMMA, and 0.40 (0.55) for silicone IOLs (p=0.004). Scores between rabbit posterior capsule and IOL optic displayed a similar tendency; 4.50 (0.84) for acrylic foldable, 3.00 (1.00) for PMMA, and 0.40 (0.55) for silicone IOLs (p=0.021). Histological observation indicated that the edge of IOL optic suppressed the migration of lens epithelial cells towards the centre of the posterior capsule. This inhibitory effect was most pronounced with acrylic foldable IOL and least with silicone IOL. Conclusions-The acrylic foldable IOL adhered to the lens capsule more than the PMMA IOL, and the silicone IOL showed no adhesiveness. These differences seem to play a role in preventing lens epithelial cells from migrating and forming posterior capsule opacification.
引用
收藏
页码:549 / 553
页数:5
相关论文
共 31 条
[1]   POSTERIOR CAPSULE OPACIFICATION [J].
APPLE, DJ ;
SOLOMON, KD ;
TETZ, MR ;
ASSIA, EI ;
HOLLAND, EY ;
LEGLER, UFC ;
TSAI, JC ;
CASTANEDA, VE ;
HOGGATT, JP ;
KOSTICK, AMP .
SURVEY OF OPHTHALMOLOGY, 1992, 37 (02) :73-116
[2]   EFFECT OF INTRAOCULAR-LENS OPTIC DESIGN ON POSTERIOR CAPSULAR OPACIFICATION [J].
BORN, CP ;
RYAN, DK .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (02) :188-192
[3]   MACROMOLECULAR ORGANIZATION OF BOVINE LENS CAPSULE [J].
CAMMARATA, PR ;
CANTUCROUCH, D ;
OAKFORD, L ;
MORRILL, A .
TISSUE & CELL, 1986, 18 (01) :83-97
[4]  
CUMMING JS, 1994, EUR J IMPLANT REFRAC, V6, P200
[5]  
Davis P, 1989, EUR J IMPLANT REFRAC, V1, P237
[6]   COMPLICATIONS OF SILICONE DISC INTRAOCULAR LENSES [J].
DUNCKER, GIW ;
WESTPHALEN, S ;
BEHRENDT, S .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (05) :562-566
[7]  
FEZZOTTI R, 1990, J CATARACT REFR SURG, V16, P347
[8]   RESTORING LENS CAPSULE INTEGRITY ENHANCES LENS REGENERATION IN NEW-ZEALAND ALBINO RABBITS AND CATS [J].
GWON, A ;
GRUBER, LJ ;
MANTRAS, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (06) :735-746
[9]   POSTERIOR CAPSULE FIBROSIS AND INTRAOCULAR-LENS DESIGN [J].
HANSEN, TE ;
OTLAND, N ;
CORYDON, L .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (04) :383-386
[10]   EFFICACY OF EQUATOR RINGS IN AN EXPERIMENTAL RABBIT STUDY [J].
HARA, T ;
HARA, T ;
SAKANISHI, K ;
YAMADA, Y .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (08) :1060-1065