Determination of hydrogen peroxide using a potassium hexacyanoferrate(III) modified titanium dioxide electrode

被引:25
作者
Mishima, Y [1 ]
Motonaka, J [1 ]
Maruyama, K [1 ]
Ikeda, S [1 ]
机构
[1] Univ Tokushima, Fac Engn, Dept Chem Sci & Technol, Tokushima 770, Japan
关键词
hydrogen peroxide; potassium hexacyanoferrate(III); titanium dioxide;
D O I
10.1016/S0003-2670(97)00650-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A titanium dioxide electrode modified with potassium hexacyanoferrate(III) was developed. Since potassium hexacyanoferrate(III) has a rapid electron transfer rate, the conductivity of the modified electrode was much better than at a bare titanium dioxide electrode. With this electrode, hydrogen peroxide (from 1.66 x 10(-6) to 3.22 x 10(-3) M) could be determined accurately with a relative standard deviation of less than 7.0%, in the presence of a molar ratio of 1:10 sodium chloride, potassium chloride, potassium bromide, sodium sulfate, beta-D-glucose, or nicotinamide, 1:1 sodium iodide, sulfonic acid, nitric acid, uric acid, or L-ascorbic acid or 1:0.1 L-serine or L-phenylalanine. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:291 / 296
页数:6
相关论文
共 11 条
[1]   TIO2-BASED PHOTOELECTRODES IN PHOTOELECTROCHEMICAL CELLS - PERFORMANCE AND MECHANISM OF O-2 EVOLUTION [J].
ANTONUCCI, V ;
PASSALACQUA, E ;
GIORDANO, N .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 1987, 12 (05) :305-313
[2]   AMPEROMETRIC BIOSENSORS BASED ON THE IMMOBILIZATION OF OXIDASES IN A PRUSSIAN BLUE FILM BY ELECTROCHEMICAL CODEPOSITION [J].
CHI, QJ ;
DONG, SJ .
ANALYTICA CHIMICA ACTA, 1995, 310 (03) :429-436
[3]  
GUIBAULT GG, 1973, ANAL CHIM ACTA, V64, P439
[4]   AMPEROMETRIC ENZYMATIC DETERMINATION OF TOTAL CHOLESTEROL IN HUMAN-SERUM WITH TUBULAR CARBON ELECTRODES [J].
HAHN, Y ;
OLSON, CL .
ANALYTICAL CHEMISTRY, 1979, 51 (03) :444-449
[5]   KINETICS OF THE FE(CN)63-/FE(CN)64- COUPLE AT PASSIVE TITANIUM ELECTRODES [J].
HURLEN, T ;
WILHELMSEN, W .
ELECTROCHIMICA ACTA, 1988, 33 (12) :1729-1733
[6]   DEVELOPMENT OF A NEEDLE-TYPE GLUCOSE SENSOR-BASED ON A TITANIUM-DIOXIDE OXYGEN-ELECTRODE FOR THE ARTIFICIAL PANCREAS [J].
IKEDA, S ;
HARA, M ;
HISHIDA, Y ;
KIMURA, M ;
ITO, K .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 13 (1-3) :315-318
[7]   PRUSSIAN BLUE BASED FIRST-GENERATION BIOSENSOR - A SENSITIVE AMPEROMETRIC ELECTRODE FOR GLUCOSE [J].
KARYAKIN, AA ;
GITELMACHER, OV ;
KARYAKINA, EE .
ANALYTICAL CHEMISTRY, 1995, 67 (14) :2419-2423
[8]  
KULIS JJ, 1983, ANAL CHIM ACTA, V148, P13
[9]   INDIRECT REDUCTION OF P-NITROANILINE TO P-PHENYLENEDIAMINE AT A TI/TIO2 ELECTRODE [J].
RAVICHANDRAN, C ;
VASUDEVAN, D ;
ANANTHARAMAN, PN .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 1992, 22 (02) :179-181
[10]   ELECTRON-TRANSFER REACTIONS OF TITANIUM(III)/(IV) ON PASSIVE TITANIUM [J].
WILHELMSEN, W .
ACTA CHEMICA SCANDINAVICA, 1989, 43 (04) :345-350