Comprehensive two-dimensional gas chromatography and chemometrics for the high-speed quantitative analysis of aromatic isomers in a jet fuel using the standard addition method and an objective retention time alignment algorithm

被引:125
作者
Fraga, CG [1 ]
Prazen, BJ [1 ]
Synovec, RE [1 ]
机构
[1] Univ Washington, Dept Chem, Ctr Proc Analyt Chem, Seattle, WA 98195 USA
关键词
D O I
10.1021/ac000303b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-speed quantitative analysis of aromatic isomers in a jet fuel sample is performed using comprehensive two-dimensional gas chromatography (GC x GC) and chemometrics. A GC x GC separation time of 2.8 min is achieved for three aromatic isomers in jet fuel, which is 5 times faster than a reference method in which a single-column separation resolves two of the three isomers of interest, The high-speed GC x GC separation is more than 10 times faster than a recent GC x GC separation that fully resolves the three components of interest in gasoline. The high-speed GC x GC analysis of jet fuel is accomplished through short GC columns, high gas velocities, and partial chromatographic peak resolution followed by chemometric resolution of overlapped peaks, The standard addition method and an objective retention time alignment algorithm are used to correct for retention time variations prior to the chemometric data analysis. The standard addition method corrects for chemical matrix effects that cause analytes in complex samples to have peak shapes, widths, and retention times that differ considerably from those of calibration standards in pure solvents. The retention time alignment algorithm corrects for the relatively small retention time variations caused by fluctuating instrumental parameters such as now rate and temperature. The use of data point interpolation in the retention time alignment algorithm results in a more accurate retention time correction then previously achieved. The generalized rank annihilation method (GRAM) is the chemometric technique used to resolve the overlapped GC x GC peaks. The correction of retention time variations allows for successful GRAM;I signal deconvolution, Using the retention time alignment algorithm, GRAM quantification accuracy and precision are improved by a factor of 4. The methodology used in this paper should be applicable to other comprehensive separation methods, such as two-dimensional liquid chromatography, Liquid chromatography coupled with capillary electro-phoresis, and Liquid chromatography coupled with gas chromatography.
引用
收藏
页码:4154 / 4162
页数:9
相关论文
共 42 条
[1]   Generalized rank annihilation method applied to a single multicomponent pulsed gradient spin echo NMR data set [J].
Antalek, B ;
Windig, W .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (42) :10331-10332
[2]  
Blomberg J, 1997, HRC-J HIGH RES CHROM, V20, P539
[3]   Comprehensive two dimensional high-speed gas chromatography with chemometric analysis [J].
Bruckner, CA ;
Prazen, BJ ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2796-2804
[4]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :161-167
[5]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY CAPILLARY ZONE ELECTROPHORESIS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :978-984
[6]  
Dietz EA, 1996, HRC-J HIGH RES CHROM, V19, P485
[7]   GENERALIZED RANK ANNIHILATION METHOD .1. DERIVATION OF EIGENVALUE PROBLEMS [J].
FABER, NM ;
BUYDENS, LMC ;
KATEMAN, G .
JOURNAL OF CHEMOMETRICS, 1994, 8 (02) :147-154
[8]  
Felinger A., 1998, DATA ANAL SIGNAL PRO
[9]  
FRAGA CG, 2000, J HIGH RES CHROMATOG, V23, P215
[10]  
Frysinger GS, 1999, HRC-J HIGH RES CHROM, V22, P195