A multicenter controlled clinical trial of open versus endovascular treatment of abdominal aortic aneurysm

被引:259
作者
Matsumura, JS
Brewster, DC
Makaroun, MS
Naftel, DC
机构
[1] Northwestern Univ, Sch Med, Dept Surg, Chicago, IL 60611 USA
[2] Harvard Univ, Boston, MA USA
[3] Univ Pittsburgh, Pittsburgh, PA USA
[4] Univ Alabama Birmingham, Birmingham, AL USA
关键词
D O I
10.1067/mva.2003.120
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The purpose of this study was to evaluate the safety and efficacy of a novel endovascular graft for elective treatment of infrarenal abdominal aortic aneurysm. The device is a modular bifurcated system with nitinol/expanded polytetrafluoroethylene components and a smaller profile than currently approved devices. Methods. In a multicenter, concurrent controlled phase II trial, 334 patients underwent treatment with the Excluder bifurcated endoprosthesis (test, n = 235; W. L. Gore & Associates, Inc, Sunnyvale, Calif) or with standard open repair (control, n = 99). Preoperative characteristics, perioperative variables, follow-up clinical evaluations, and radiographic examination results through the first 2 years were analyzed with univariable and multivariable statistics. Results. Patients in the test group had less blood loss (310 +/- 19 mL versus 1590 +/- 124 mL; P < .0001), fewer homologous transfusions (6% versus 32%; P < .0001), and shorter lengths of stay (2.0 +/- 0.1 days versus 9.8 +/- 1.4 days; P < .0001). Early major adverse events were markedly reduced in the test group (14% versus 57%; P < .0001), and this difference persisted at 2 years. No difference was seen in survival rate (P =.13). In the first 2 years, no deployment failure, early conversion, or aneurysm rupture occurred. At the 2-year timepoint, core laboratory read trunk migration in 1%, limb migration in 1%, limb narrowing in 1%, endoleak in 20%, and aneurysm growth in 14%. One wire discontinuity (0.6%) was identified in a discharge film. A 7% annual reintervention rate was seen in the test group in the first 2 years. Summary. The test device is a safe and effective treatment compared with open surgical repair for infrarenal abdominal aortic aneurysm. The most striking benefits are reduced blood loss, fewer complications, and faster recovery. Two-year survival rate was similar.
引用
收藏
页码:262 / 271
页数:10
相关论文
共 40 条
[1]   Reporting standards for infrarenal endovascular abdominal aortic aneurysm repair [J].
Ahn, SS ;
Rutherford, RB ;
Johnston, KW ;
May, J ;
Veith, FJ ;
Baker, JD ;
Ernst, CB ;
Moore, WS .
JOURNAL OF VASCULAR SURGERY, 1997, 25 (02) :405-410
[2]   Mid-term results of a second generation bifurcated endovascular graft for abdominal aortic aneurysm repair: The French Vanguard trial [J].
Becquemin, JP ;
Lapie, V ;
Favre, JP ;
Rousseau, H .
JOURNAL OF VASCULAR SURGERY, 1999, 30 (02) :209-218
[3]  
Beebe HG, 2001, J VASC SURG, V33, pS55
[4]   Ruptured abdominal aortic aneurysm after endovascular repair [J].
Bernhard, VM ;
Mitchell, RS ;
Matsumura, JS ;
Brewster, DC ;
Decker, M ;
Lamparello, P ;
Raithel, D ;
Collin, J .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (06) :1155-1162
[5]   Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms [J].
Blum, U ;
Voshage, G ;
Lammer, J ;
Beyersdorf, F ;
Tollner, D ;
Kretschmer, G ;
Spillner, G ;
Polterauer, P ;
Nagel, G ;
Holzenbein, T ;
Thurnher, S ;
Langer, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (01) :13-20
[6]   Initial experience with endovascular aneurysm repair: Comparison of early results with outcome of conventional open repair [J].
Brewster, DC ;
Geller, SC ;
Kaufman, JA ;
Cambria, RP ;
Gertler, JP ;
LaMuraglia, GM ;
Atamian, S ;
Abbott, WM .
JOURNAL OF VASCULAR SURGERY, 1998, 27 (06) :992-1003
[7]   Early experience with the bifurcated Excluder endoprosthesis for treatment of the abdominal aortic aneurysm [J].
Bush, RL ;
Najibi, S ;
Lin, PH ;
Weiss, VJ ;
MacDonald, MJ ;
Redd, DC ;
Martin, LG ;
Chaikof, EL ;
Lumsden, AB .
JOURNAL OF VASCULAR SURGERY, 2001, 34 (03) :497-502
[8]   Identifying and grading factors that modify the outcome of endovascular aortic aneurysm repair [J].
Chaikof, EL ;
Fillinger, MF ;
Matsumura, JS ;
Rutherford, RB ;
White, GH ;
Blankensteijn, JD ;
Bernhard, VM ;
Harris, PL ;
Kent, KC ;
May, J ;
Veith, FJ ;
Zarins, CK .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (05) :1061-1066
[9]   Reporting standards for endovascular aortic aneurysm repair [J].
Chaikof, EL ;
Blankensteijn, JD ;
Harris, PL ;
White, GH ;
Zarins, CK ;
Bernhard, VM ;
Matsumura, JS ;
May, J ;
Veith, FJ ;
Fillinger, MF ;
Rutherford, RB ;
Kent, KC .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (05) :1048-1060
[10]   Endovascular treatment of abdominal aortic aneurysm: a failed experiment [J].
Collin, J ;
Murie, JA .
BRITISH JOURNAL OF SURGERY, 2001, 88 (10) :1281-1282