Subjective scoring of cough in children: parent-completed vs child-completed diary cards vs an objective method

被引:159
作者
Chang, AB
Newman, RG
Carlin, JB
Phelan, PD
Robertson, CF
机构
[1] Univ Melbourne, Royal Childrens Hosp, Dept Thorac Med, Melbourne, Vic 3052, Australia
[2] Univ Melbourne, Royal Childrens Hosp, Dept Biomed Engn, Melbourne, Vic 3052, Australia
[3] Univ Melbourne, Royal Childrens Hosp, Dept Clin Epidemiol & Stat, Melbourne, Vic 3052, Australia
[4] Univ Melbourne, Royal Childrens Hosp, Dept Paediat, Melbourne, Vic 3052, Australia
关键词
cough; cough meter; score;
D O I
10.1183/09031936.98.11020462
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Cough is often used as an outcome measure, although the reporting of cough is unreliable. Using a 24 h ambulatory cough meter to measure cough frequency, the aim of this study was to compare: 1) the correlation of child-completed diary cards to the objective measurement, with that of parent-completed diary cards; and 2) the visual analogue scale (VAS) to the verbal category descriptive (VCD) score, The cough meter consisted of a previously validated Holter monitor and a cough processor. Eighty four children (39 with recurrent cough and 45 controls, aged 6-17 yrs) used a cough meter at least once, Thirty three subjects used the cough meter twice, Parents and children completed separate diary cards using the VAS and VCD scores. The strength of the relationship between the subjective scores and the subjective recordings was analysed by spearman's rank correlation coefficient, For daytime cough, child-completed diary cards and the VCD correlated better to the objective measurement than parent-completed diary cards and the VAS, respectively. In subjects that used the cough meter twice, the difference between the cough frequency correlated to the difference in the subjective scores, The confidence intervals for the correlation coefficients were wide, The agreement between the objective and subjective presence of daytime cough was good but that for night-time cough was poor, We conclude that the severity of cough defined on diary cards may not represent cough frequency. Objective readings are first choice but currently not yet practical, The verbal category descriptive diary card completed by children and assisted by parents has the highest correlation to cough frequency measured objectively.
引用
收藏
页码:462 / 466
页数:5
相关论文
共 24 条
  • [1] Altman D.G., 1991, PRACTICAL STAT MED R, V1st, P403, DOI [10.1002/sim.4780101015, DOI 10.1002/SIM.4780101015]
  • [2] ALTMAN DG, 1991, PRACTICAL STAT MED R, P293
  • [3] NIGHT COUGH COUNTS AND DIARY CARD SCORES IN ASTHMA
    ARCHER, LNJ
    SIMPSON, H
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1985, 60 (05) : 473 - 474
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] A new use for an old Holter monitor: An ambulatory cough meter
    Chang, AB
    Newman, RG
    Phelan, PD
    Robertson, CF
    [J]. EUROPEAN RESPIRATORY JOURNAL, 1997, 10 (07) : 1637 - 1639
  • [6] PREVALENCE OF RESPIRATORY SYMPTOMS AMONG 7-YEAR-OLD AND 11-YEAR-OLD SCHOOLCHILDREN AND ASSOCIATION WITH ASTHMA
    CLIFFORD, RD
    RADFORD, M
    HOWELL, JB
    HOLGATE, ST
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1989, 64 (08) : 1118 - 1125
  • [7] CLOUGH JB, 1995, EUR RESPIR J, V8, P817
  • [8] THE INFLUENCE OF PSYCHOLOGICAL STATUS ON RESPIRATORY SYMPTOM REPORTING
    DALES, RE
    SPITZER, WO
    SCHECHTER, MT
    SUISSA, S
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 139 (06): : 1459 - 1463
  • [9] POOR AGREEMENT BETWEEN REPORTED AND RECORDED NOCTURNAL COUGH IN ASTHMA
    FALCONER, A
    OLDMAN, C
    HELMS, P
    [J]. PEDIATRIC PULMONOLOGY, 1993, 15 (04) : 209 - 211
  • [10] HOSKYNS EW, 1995, EUR J PEDIATR, V154, P320, DOI 10.1007/s004310050298