Evaluation of diagnostic reliability of DCA 2000 for rapid and simple monitoring of HbA1c

被引:55
作者
Arsie, MP
Marchioro, L
Lapolla, A
Giacchetto, GF
Bordin, MR
Rizzotti, P
Fedele, D
机构
[1] Univ Padua, Dept Med & Surg Sci, Diabet Serv, I-35100 Padua, Italy
[2] Geriatr Hosp, Clin Pathol Lab, Padua, Italy
关键词
diabetes; metabolic control; glycated hemoglobin;
D O I
10.1007/s005920070028
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The monitoring of diabetic patients by evaluating glycated protein levels is now widely accepted and performed. The microchromatographic version of the high performance liquid chromatography method is the technique most frequently used in clinical practice. The DCA 2000 instrument (Bayer Diagnostics, Milan, Italy), based on an immunochemical technique, has been proposed for the rapid and simple evaluation of HbA1c, using even capillary blood. We evaluated 171 subjects including 22 healthy volunteers, 78 type 2 diabetic patients with different degrees of metabolic control, 11 women affected by gestational diabetes mellitus (GDM), 6 patients with hyperlipemia, 38 patients with chronic renal failure, 13 diabetic patients with chronic renal failure, and 3 patients with hemoglobinopathies. The DCA 2000 model was compared with the Diamat HPLC system. Data from within-run imprecision studies showed excellent precision, for both DCA 2000 and the HPLC system. The correlation between the two different systems, as shown by other statistical evaluations, was good (y = 0.911x + 0.462, r = 0.923). Results from the control group and diabetic patients were used to compare the two methods. Values obtained using the DCA 2000 were significantly lower (p < 0.0001) than those obtained with the HPLC system, in both healthy subjects and diabetic patients. To detect possible interferences, selected samples were analyzed from patients with hyperlipemia, diabetes and chronic renal failure, and hemoglobinopathies. While in the case of hyperlipemia, an acceptable correlation coefficient between the two systems was confirmed (y = 1.047x - 1.236, r = 0.876), in the case of chronic renal failure the correlation turned out to be very low (y = 0.254x + 3.456, r = 0.203). Our results indicate that the DCA 2000 gives accurate and reliable results in the clinical field of interest.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 37 条
[1]  
BANAUCH D, 1975, Z KLIN CHEM KLIN BIO, V13, P101
[2]   IMPROVED COLOR REAGENT FOR DETERMINATION OF BLOOD-GLUCOSE BY OXIDASE SYSTEM [J].
BARHAM, D ;
TRINDER, P .
ANALYST, 1972, 97 (1151) :142-&
[3]  
Baumann GH, 1997, CLIN CHEM, V43, P511
[4]   NATIONAL DIABETES DATA GROUP - REPORT OF THE EXPERT COMMITTEE ON GLUCOSYLATED HEMOGLOBIN [J].
BAYNES, JW ;
BUNN, HF ;
GOLDSTEIN, D ;
HARRIS, M ;
MARTIN, DB ;
PETERSON, C ;
WINTERHALTER, K .
DIABETES CARE, 1984, 7 (06) :602-606
[5]   Comparison of hemoglobin A1C results by two different methods on patients with structural hemoglobin variants [J].
Blakney, GB ;
Higgins, TN ;
Holmes, DJ .
CLINICAL BIOCHEMISTRY, 1998, 31 (08) :619-626
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]  
BODOR GS, 1992, CLIN CHEM, V38, P2414
[8]   GLYCOSYLATION OF HEMOGLOBIN - RELEVANCE TO DIABETES-MELLITUS [J].
BUNN, HF ;
GABBAY, KH ;
GALLOP, PM .
SCIENCE, 1978, 200 (4337) :21-27
[9]   DEVELOPMENT OF A LASER NEPHELOMETRIC METHOD FOR THE QUANTITATION OF HUMAN GLYCOHEMOGLOBINS [J].
CHOU, PP ;
KERKAY, J ;
GUPTA, MK .
ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1981, 14 (13) :1071-1087
[10]  
Costa A, 1999, MED CLIN-BARCELONA, V112, P241