Effects of material properties and geometry on electrocardiographic forward simulations

被引:44
作者
Bradley, CP [1 ]
Pullan, AJ [1 ]
Hunter, PJ [1 ]
机构
[1] Univ Auckland, Dept Engn Sci, Auckland, New Zealand
关键词
forward problem; electrocardiographic simulation; conductivity effects; geometric effects; coupled FEM/BEM; high order interpolation;
D O I
10.1114/1.1289467
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper investigates the effect on torso potentials of changes in the material properties of the torso volume conductor and changes in the relative geometry of the heart and torso. The investigations are performed using a number of forward simulations with a high-order coupled finite element/boundary clement torso model. This torso model contains descriptions of the epicardium, lungs, skeletal muscle (with a continuously varying fiber field) and subcutaneous fat. The number of nodes, elements and solution degrees-of-freedom used in the computational torso model are considerably smaller than previous torso models of similar complexity. The successful forward simulations in this paper hence demonstrate the use of the high-order coupled approach with realistic problems. The results of the torso simulations show that the torso inhomogeneities do affect the torso potentials but do not affect the distribution or pattern of the torso potentials. The inhomogeneities considered are found to have a varying, but important, effect on the torso potentials. The effect of the subcutaneous fat is found to be more important and the effect of the skeletal muscle is found to be less important than previous reports in the literature. The results also show that the relative geometry of the heart and torso is very important in determining the torso potential magnitudes and distributions. (C) 2000 Biomedical Engineering Society. [S0090-6964(00)00407-0].
引用
收藏
页码:721 / 741
页数:21
相关论文
共 44 条
[1]   EFFECTS OF VARYING THE ELECTRICAL-CONDUCTIVITY OF THE MEDIUM BETWEEN THE HEART AND THE BODY-SURFACE ON THE EPICARDIAL AND PRAECORDIAL ELECTROCARDIOGRAM IN THE PIG [J].
AKIYAMA, T ;
RICHESON, JF ;
INGRAM, JT ;
ORAVEC, J .
CARDIOVASCULAR RESEARCH, 1978, 12 (12) :697-702
[2]   Geometric modeling of the human torso using cubic hermite elements [J].
Bradley, CP ;
Pullan, AJ ;
Hunter, PJ .
ANNALS OF BIOMEDICAL ENGINEERING, 1997, 25 (01) :96-111
[3]  
BRADLEY CP, 1998, UNPUB IEEE T BIOMED
[5]  
BUDGETT DM, 1993, J ELECTROCARDIOL, V26, P165
[6]   A VOLUME CONDUCTOR MODEL OF THE THORAX FOR THE STUDY OF DEFIBRILLATION FIELDS [J].
CLAYDON, FJ ;
PILKINGTON, TC ;
TANG, ASL ;
MORROW, MN ;
IDEKER, RE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (11) :981-992
[7]   On the contribution of volume currents to the total magnetic field resulting from the heart excitation process: A simulation study [J].
Czapski, P ;
Ramon, C ;
Huntsman, LL ;
Bardy, GH ;
Kim, Y .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (01) :95-104
[8]  
DOWNER CE, 1980, CLIN CARDIOL, V3, P87
[9]  
FOSTER KR, 1989, CRIT REV BIOMED ENG, V17, P25
[10]   SPECIFIC RESISTANCE OF BIOLOGICAL MATERIAL-A COMPENDUM OF DATA FOR BIOMEDICAL ENGINEER AND PHYSIOLOGIST [J].
GEDDES, LA ;
BAKER, LE .
MEDICAL & BIOLOGICAL ENGINEERING, 1967, 5 (03) :271-&