Effect of the molecular adsorbent recirculating system and Prometheus devices on systemic haemodynamics and vasoactive agents in patients with acute-on-chronic alcoholic liver failure

被引:175
作者
Laleman, Wim
Wilmer, Alexander
Evenepoel, Pieter
Elst, Ingrid Vander
Zeegers, Marcel
Zaman, Zahur
Verslype, Chris
Fevery, Johan
Nevens, Frederik [1 ]
机构
[1] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Dept HEpatol, Louvain, Belgium
[2] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Dept Med Intens Care, Louvain, Belgium
[3] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Dept Nephrol, Louvain, Belgium
[4] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Dept Lab Med, Louvain, Belgium
来源
CRITICAL CARE | 2006年 / 10卷 / 04期
关键词
D O I
10.1186/cc4985
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction Patients with acute-on-chronic liver failure show an aggravated hyperdynamic circulation. We evaluated, in a controlled manner, potential changes in systemic haemodynamics induced by the molecular adsorbent recirculating system (MARS) and the Prometheus system liver detoxification devices in a group of patients with acute-on-chronic liver failure. Methods Eighteen patients (51.2 +/- 2.3 years old; Child - Pugh score, 12.5 +/- 0.2; Maddrey score, 63.1 +/- 5.0; hepatic venous pressure gradient, 17.6 +/- 0.9 mmHg) with biopsy-proven alcoholic cirrhosis and superimposed alcoholic hepatitis were either treated with standard medical therapy (SMT) combined with MARS (n = 6) or Prometheus ( n = 6) or were treated with SMT alone ( n = 6) on three consecutive days ( 6 hours/session). Liver tests, systemic haemodynamics and vasoactive substances were determined before and after each session. Results Groups were comparable for baseline haemodynamics and levels of vasoactive substances. Both MARS and Prometheus decreased serum bilirubin levels ( P < 0.005 versus SMT), the Prometheus device being more effective than MARS ( P = 0.002). Only MARS showed significant improvement in the mean arterial pressure (Delta change, + 9 +/- 2.4 mmHg versus - 0.3 +/- 2.4 mmHg with Prometheus and - 5.2 +/- 2.1 mmHg with SMT, P < 0.05) and in the systemic vascular resistance index (Delta change, + 131.5 +/- 46.2 dyne. s/ cm(5)/ m(2) versus - 92.8 +/- 85.2 dyne. s/ cm(5)/ m(2)with Prometheus and - 30.7 +/- 32.5 dyne. s/ cm(5)/ m(2) with SMT; P < 0.05), while the cardiac index and central filling remained constant. This circulatory improvement in the MARS group was paralleled by a decrease in plasma renin activity ( P < 0.05), aldosterone ( P < 0.03), norepinephrine ( P < 0.05), vasopressin ( P = 0.005) and nitrate/nitrite levels ( P < 0.02). Conclusion The MARS device, and not the Prometheus device, significantly attenuates the hyperdynamic circulation in acute-on-chronic liver failure, presumably by a difference in removal rate of certain vasoactive substances. These findings suggest conspicuous conceptual differences among the albumin dialysis devices.
引用
收藏
页数:13
相关论文
共 50 条
[1]   Complications of cirrhosis.: II.: Renal and circulatory dysfunction.: Lights and shadows in an important clinical problem [J].
Arroyo, V ;
Jiménez, W .
JOURNAL OF HEPATOLOGY, 2000, 32 :157-170
[2]   Complications of cirrhosis.: I.: Portal hypertension [J].
Bosch, J ;
García-Pagán, JC .
JOURNAL OF HEPATOLOGY, 2000, 32 :141-156
[3]   Increased endothelial nitric oxide synthase activity in the hyperemic vessels of portal hypertensive rats [J].
Cahill, PA ;
Redmond, EM ;
Hodges, R ;
Zhang, SM ;
Sitzmann, JV .
JOURNAL OF HEPATOLOGY, 1996, 25 (03) :370-378
[4]   Hepatic and systemic haemodynamic changes after MARS in patients with acute on chronic liver failure [J].
Catalina, MV ;
Barrio, J ;
Anaya, F ;
Salcedo, M ;
Rincón, D ;
Clemente, G ;
Bañares, R .
LIVER INTERNATIONAL, 2003, 23 :39-43
[5]   A prognostic model for patients with end-stage liver disease [J].
Cooper, GS ;
Bellamy, P ;
Dawson, NV ;
Desbiens, N ;
Fulkerson, WJ ;
Goldman, L ;
Quinn, LM ;
Speroff, T ;
Landefeld, CS .
GASTROENTEROLOGY, 1997, 113 (04) :1278-1288
[6]   Continuous and intermittent cardiac output measurement:: pulmonary artery catheter versus aortic transpulmonary technique [J].
Della Rocca, G ;
Costa, MG ;
Pompei, L ;
Coccia, C ;
Pietropaoli, P .
BRITISH JOURNAL OF ANAESTHESIA, 2002, 88 (03) :350-356
[7]   Prometheus versus molecular adsorbents recirculating system: Comparison of efficiency in two different liver detoxification devices [J].
Evenepoel, P ;
Laleman, T ;
Wilmer, A ;
Claes, K ;
Kuypers, D ;
Barnmens, B ;
Nevens, F ;
Vanrenterghem, Y .
ARTIFICIAL ORGANS, 2006, 30 (04) :276-284
[8]   Detoxifying capacity and kinetics of the molecular adsorbent recycling system - Contribution of the different inbuilt filters [J].
Evenepoel, P ;
Maes, B ;
Wilmer, A ;
Nevens, F ;
Fevery, J ;
Kuypers, D ;
Bammens, B ;
Vanrenterghem, Y .
BLOOD PURIFICATION, 2003, 21 (03) :244-252
[9]   A prognostic model for predicting survival in cirrhosis with ascites [J].
Fernández-Esparrach, G ;
Sánchez-Fueyo, A ;
Ginès, P ;
Uriz, J ;
Quintó, L ;
Ventura, PJ ;
Cárdenas, A ;
Guevara, M ;
Sort, P ;
Jiménez, W ;
Bataller, R ;
Arroyo, V ;
Rodés, J .
JOURNAL OF HEPATOLOGY, 2001, 34 (01) :46-52
[10]   SYSTEMIC AND REGIONAL HEMODYNAMICS IN PATIENTS WITH LIVER-CIRRHOSIS AND ASCITES WITH AND WITHOUT FUNCTIONAL RENAL-FAILURE [J].
FERNANDEZSEARA, J ;
PRIETO, J ;
QUIROGA, J ;
ZOZAYA, JM ;
COBOS, MA ;
RODRIGUEZEIRE, JL ;
GARCIAPLAZA, A ;
LEAL, J .
GASTROENTEROLOGY, 1989, 97 (05) :1304-1312